• ABB ASL16-30-32S-81M ASL16-30-32S-81M 24VDC Contactor Product Image
  • Abb ASL16-30-32S-81M Barcode

ASL16-30-32S-81M

Let Us Find It

Current response time:

By 5AM PT on Tuesday
  • Description: ASL16-30-32S-81M 24VDC Contactor
  • Product ID: 1SBL123004M8132
  • Extended Product Type: 1SBL123004M8132
  • Product Net Weight: 0.320 kg
  • Product Net Width: 45 mm
  • Product Net Height: 68 mm
  • Product Net Depth: 110.7 mm
  • Degree of Protection: acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20 acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20
  • Ambient Air Temperature: Close to Contactor for Storage -60 ... +80 C Close to Contactor Fitted with Thermal O/L Relay -25 ... +60 C Close to Contactor without Thermal O/L Relay -40 ... +70 C
  • Standards: IEC 60947-1 / 60947-4-1 and EN 60947-1 / 60947-4-1, UL 508, CSA C22.2 N14
  • Rated Impulse Withstand Voltage (U<sub>imp</sub>): 6 kV
  • Rated Insulation Voltage (U<sub>i</sub>): acc. to UL/CSA 600 V acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V acc. to IEC 60947-5-1 and VDE 0110 (Gr. C) 690 V
  • Terminal Type: Spring Terminals
  • Rated Frequency (f): Auxiliary Circuit 50 / 60 Hz Main Circuit 50 / 60 Hz
  • Number of Auxiliary Contacts NO: 3
  • Number of Auxiliary Contacts NC: 2
  • Connecting Capacity Main Circuit: Flexible with Insulated Ferrule 1/2x 0.75 ... 1.5 mm Flexible with Ferrule 1/2x 0.75 ... 2.5 mm Rigid 1/2x 0.75 ... 2.5 mm
  • GOST Certificate: GOST_POCCCNME77B07822.pdf
  • Maximum Operating Altitude Permissible: 3000 m
  • Rated Control Circuit Voltage (U<sub>c</sub>): DC Operation 24 V
  • Climatic Withstand: Category B according to IEC 60947-1 Annex Q
  • Maximum Mechanical Switching Frequency: 3600 cycles per hour
  • Connecting Capacity Auxiliary Circuit: Flexible with Ferrule 1/2x 0.75 ... 2.5 mm Flexible with Insulated Ferrule 1/2x 0.75 ... 1.5 mm Rigid 1/2x 0.75 ... 2.5 mm
  • Operate Time: Between Coil De-energization and NC Contact Closing 15 ... 20 ms Between Coil De-energization and NO Contact Opening 13 ... 17 ms Between Coil Energization and NC Contact Opening 31 ... 53 ms Between Coil Energization and NO Contact Closing 36 ... 59 ms
  • Wire Stripping Length: Auxiliary Circuit 10 mm Control Circuit 10 mm Main Circuit 10 mm
  • Number of Main Contacts NO: 3
  • Number of Main Contacts NC: 0
  • Maximum Breaking Capacity: cos phi=0.45 (cos phi=0.35 for Ie &gt; 100 A) at 440 V 155 A cos phi=0.45 (cos phi=0.35 for Ie &gt; 100 A) at 690 V 90 A
  • Connecting Capacity Control Circuit: Flexible with Ferrule 1/2x 0.75 ... 2.5 mm Flexible with Insulated Ferrule 1/2x 0.75 ... 1.5 mm Rigid 1/2x 0.75 ... 2.5 mm
  • Horsepower Rating UL/CSA: (120 V AC) Single Phase 3/4 Hp (240 V AC) Single Phase 2 Hp (200 ... 208 V AC) Three Phase 3 Hp (220 ... 240 V AC) Three Phase 5 Hp (440 ... 480 V AC) Three Phase 10 Hp (550 ... 600 V AC) Three Phase 10 Hp
  • General Use Rating UL/CSA: (600 V AC) 15.2 A
  • EAN: 3471523062719
  • Minimum Order Quantity: 20 piece
  • Customs Tariff Number: 85369085
  • Package Level 1 Width: 293 mm
  • Package Level 1 Length: 128 mm
  • Package Level 1 Height: 247 mm
  • Package Level 1 Gross Weight: 6.4 kg
  • Package Level 1 EAN: 3471523062719
  • Package Level 3 Units: 640 piece
  • Package Level 1 Units: 20 piece
  • Rated Operational Voltage: Auxiliary Circuit 690 V Main Circuit 690 V
  • Conventional Free-air Thermal Current (I<sub>th</sub>): acc. to IEC 60947-4-1, Open Contactors q = 40 C 22 A acc. to IEC 60947-5-1, q = 40 C 10 A
  • Rated Operational Current AC-1 (I<sub>e</sub>): (690 V) 40 C 22 A (690 V) 60 C 17 A (690 V) 70 C 14 A
  • Rated Operational Current AC-3 (I<sub>e</sub>): (220 / 230 / 240 V) 60 C 15.7 A (380 / 400 V) 60 C 15.5 A (415 V) 60 C 15.5 A (440 V) 60 C 13.6 A (500 V) 60 C 12.5 A (690 V) 60 C 9 A
  • Rated Operational Power AC-3 (P<sub>e</sub>): (220 / 230 / 240 V) 4 kW (400 V) 7.5 kW (415 V) 7.5 kW (440 V) 7.5 kW (500 V) 7.5 kW (690 V) 7.5 kW
  • Rated Operational Current AC-15 (I<sub>e</sub>): (220 / 240 V) 4 A (24 / 127 V) 6 A (400 / 440 V) 3 A (500 V) 2 A (690 V) 2 A
  • Rated Short-time Withstand Current (I<sub>cw</sub>): at 40 C Ambient Temp, in Free Air, from a Cold State 10 s 124 A at 40 C Ambient Temp, in Free Air, from a Cold State 15 min 22 A at 40 C Ambient Temp, in Free Air, from a Cold State 1 min 55 A at 40 C Ambient Temp, in Free Air, from a Cold State 1 s 250 A at 40 C Ambient Temp, in Free Air, from a Cold State 30 s 75 A for 0.1 s 140 A for 1 s 100 A
  • Maximum Electrical Switching Frequency: AC-1 600 cycles per hour AC-15 1200 cycles per hour AC-2 / AC-4 300 cycles per hour AC-3 1200 cycles per hour DC-13 900 cycles per hour
  • Rated Operational Current DC-13 (I<sub>e</sub>): (110 V) 0.55 A / 60 W (125 V) 0.55 A / 69 W (220 V) 0.27 A / 60 W (24 V) 6 A / 144 W (250 V) 0.27 A / 68 W (48 V) 2.8 A / 134 W (72 V) 1 A / 72 W
  • Resistance to Vibrations acc. to IEC 60068-2-6: 5 ... 300 Hz 3 g Closed position / 2 g Open position
  • Resistance to Shock acc. to IEC 60068-2-27: Closed, Shock Direction: B1 10 g Closed, Shock Direction: C1 20 g Closed, Shock Direction: C2 20 g Open, Shock Direction: B1 5 g Open, Shock Direction: C1 9 g Open, Shock Direction: C2 14 g Shock Direction: A 20 g Shock Direction: B2 15 g
  • RoHS Status: Planned to follow EU Directive 2002/95/EC August 18, 2005 and amendment after 2009 Q4
  • Instructions and Manuals: 1SBC101020M9701
  • CB Certificate: CB_CN13475-M1
  • CCC Certificate: CCC_2007010309251577
  • cUL Certificate: UL_20110325-E312527
  • Data Sheet, Technical Information: 1SBC100173C0201
  • Declaration of Conformity - CE: 1SBD250014U1000
  • RoHS Information: 1SBD251006E1001
  • ETIM 4: EC000066 - Magnet contactor, AC-switching
  • ETIM 5: EC000066 - Magnet contactor, AC-switching
  • ETIM 6: EC000066 - Power contactor, AC switching
  • UNSPSC: 39121529
  • Object Classification Code: Q
Santa Clara Systems specializes in hard-to-find parts. Choose from our overstock inventory and save on ASL16-30-32S-81M . Santa Clara Systems carries 36,673 items from ABB.
  • With A Non-Removable Front-Mounted 2 N.o. + 2 N.c. Auxiliary Contact Block (Mechanically-Linked Auxiliary Contacts Compliant With Annex L Of Iec 60947-5-1 Including The &quot;mechanically Linked&quot; Symbol On The Contactor Side. N.c. Mirror Contacts Compliant With Annex F Of Iec 60947-4-1) - Control Circuit: Dc Operated With Solid Core Magnet Circuit. The Polarity On The Coil Terminals (A1+ And A2-) Must Be Respected - Accessories: A Wide Range Of Accessories Is Available. Asl... Contactors Are Fitted With Low Consumption Dc Coils And Are Suitable For A Direct Control By Plc Outputs.
  • Asl16 Contactors Are Mainly Used For Controlling 3-Phase Motors And Generally For Controlling Power Circuits Up To 690 V Ac Or 220 V Dc. They Are Mainly Used For Controlling 3-Phase Motors
  • Non-Inductive Or Slightly Inductive Loads. The Asl..s Contactors Are The Spring Terminal Version Of The Asl... Range. The As... Series 2-Stack 3-Pole Contactors Are Of The Block Type Design. - Main Poles And Auxiliary Contact Blocks: 1st Stack With 3 Main Poles And 1 N.o. Built-In Auxiliary Contact

Alternates

  • 1SBL123004M8132
  • ASL16 30 32S 81M
  • ASL163032S81M

Common Typos

  • ASL16-30-325-81M
  • ASL16-30-325-8IM
  • ASL16-30-325-8LM
  • ASL16-30-325-B1M
  • ASL16-30-325-BIM
  • ASL16-30-325-BLM
  • ASL16-30-32S-8IM
  • ASL16-30-32S-8LM
  • ASL16-30-32S-B1M
  • ASL16-30-32S-BIM
  • ASL16-30-32S-BLM
  • ASL16-30-3Z5-81M
  • ASL16-30-3Z5-8IM
  • ASL16-30-3Z5-8LM
  • ASL16-30-3Z5-B1M
  • ASL16-30-3Z5-BIM
  • ASL16-30-3Z5-BLM
  • ASL16-30-3ZS-81M
  • ASL16-30-3ZS-8IM
  • ASL16-30-3ZS-8LM
  • ASL16-30-3ZS-B1M
  • ASL16-30-3ZS-BIM
  • ASL16-30-3ZS-BLM
  • ASL16-3O-32S-81M
  • ASL16-3O-32S-8IM
  • ASL16-3O-32S-8LM

Appended Numbers

  • ASL16-30-32S-81M-A
  • ASL16-30-32S-81M-B
  • ASL16-30-32S-81M-C
  • ASL16-30-32S-81M-D
  • ASL16-30-32S-81M-E
  • ASL16-30-32S-81M-F
  • ASL16-30-32S-81M-G
  • ASL16-30-32S-81M-H
  • ASL16-30-32S-81M-I
  • ASL16-30-32S-81M-J
  • ASL16-30-32S-81M-K
  • ASL16-30-32S-81M-L
  • ASL16-30-32S-81M-M
  • ASL16-30-32S-81M-N
  • ASL16-30-32S-81M-O
  • ASL16-30-32S-81M-P
  • ASL16-30-32S-81M-Q
  • ASL16-30-32S-81M-R
  • ASL16-30-32S-81M-S
  • ASL16-30-32S-81M-T
  • ASL16-30-32S-81M-U
  • ASL16-30-32S-81M-V
  • ASL16-30-32S-81M-W
  • ASL16-30-32S-81M-X
  • ASL16-30-32S-81M-Y
  • ASL16-30-32S-81M-Z

Customers Are Also Buying

We Deliver!

Late West Coast Shipping Hours
Late West Coast Shipping (5PM PST)
Drop-Ship and Blind-Ship Specialists
Expertly Packed Static-Limited
Same-Day Service
In-House Courier
visa credit card logo mastercard credit card logo discover credit card logo american express credit card logo

Customers we work with

3M logo
Kaiser Permanente logo
Safeway Logo
Georgia-Pacific logo
Coca Cola logo
duke energy logo
BART logo
Pepsi logo
LA DWP logo
US Navy logo
Dean Foods logo
ConAgra Brands logo