1SFL427102R1322
Product Summary:
- Extended Product Type: AF116-40-22B-13
- Product ID: 1SFL427102R1322
- EAN: 7320500503829
- Minimum Order Quantity: 1 piece
- Customs Tariff Number: 85364900
Let Us Find It
or
CALL 1 (888) 450-0301
- Description: AF116-40-22B-13 Contactor
- Rated Short-time Withstand Current (Icw): at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 160 A at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 928 A at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 536 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1300 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 379 A
- Maximum Breaking Capacity: cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 2000 A
- Maximum Electrical Switching Frequency: AC-1 300 cycles per hour
- Rated Insulation Voltage (Ui): acc. to UL/CSA 600 V acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V
- Rated Impulse Withstand Voltage (Uimp): Main Circuit 8 kV
- Mechanical Durability: 5 million
- Maximum Mechanical Switching Frequency: 300 cycles per hour
- Coil Operating Limits: (acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at ? ? 70 °C) °C
- Rated Control Circuit Voltage (Uc): 60 Hz 100250 V 50 Hz 100250 V DC Operation 100250 V
- Coil Consumption: Pull-in at Max. Rated Control Circuit Voltage 60 Hz 130 V·A Holding at Max. Rated Control Circuit Voltage DC 3 W Holding at Max. Rated Control Circuit Voltage 50 Hz 6 V·A Pull-in at Max. Rated Control Circuit Voltage DC 135 W Pull-in at Max. Rated Control Circuit Voltage 50 Hz 130 V·A Holding at Max. Rated Control Circuit Voltage 60 Hz 6 V·A
- Operate Time: Between Coil Energization and NO Contact Closing 2055 ms Between Coil De-energization and NO Contact Opening 4070 ms
- Connecting Capacity Main Circuit: Flexible 1x1070 mm² Rigid Cu-Cable 1x1095 mm²
- Connecting Capacity Auxiliary Circuit: Solid 2x14 mm² Flexible with Insulated Ferrule 2x0.752.5 mm² Stranded 2x14 mm² Flexible 2x0.752.5 mm² Flexible with Ferrule 2x0.752.5 mm²
- Degree of Protection: acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
- Terminal Type: Main Circuit: Bars
- Number of Main Contacts NO: 4
- Maximum Operating Altitude Permissible: 3000 m
- Ambient Air Temperature: Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25+50 °C Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40+70 °C Close to Contactor for Storage -40+70 °C
- Maximum Operating Voltage UL/CSA: Main Circuit 600 V
- ETIM 4: EC000066 - Magnet contactor, AC-switching
- ETIM 5: EC000066 - Magnet contactor, AC-switching
- Object Classification Code: Q
- Extended Product Type: AF116-40-22B-13
- Product ID: 1SFL427102R1322
- EAN: 7320500503829
- Minimum Order Quantity: 1 piece
- Customs Tariff Number: 85364900
- EAN: 7320500503829
- Product Net Depth: 128,1 mm
- Product Net Height: 150 mm
- Product Net Weight: 1.99 kg
- Product Net Width: 120 mm
- Package Level 1 Gross Weight: 2.19 kg
- Package Level 1 Units: 1 piece
- Number of Main Contacts NC: 0
- Number of Auxiliary Contacts NO: 2
- Number of Auxiliary Contacts NC: 2
- Rated Operational Voltage: Main Circuit 690 V
- Rated Frequency (f): Main Circuit 60 Hz
- Conventional Free-air Thermal Current (Ith): acc. to IEC 60947-4-1, Open Contactors q = 40 °C 160 A
- Rated Operational Current AC-1 (Ie): (690 V) 40 °C 160 A (690 V) 70 °C 130 A (690 V) 60 °C 145 A
- Rated Operational Current AC-3 (Ie): (415 V) 55 °C 116 A (220 / 230 / 240 V) 55 °C 116 A (440 V) 55 °C 116 A (380 / 400 V) 55 °C 116 A
- Rated Operational Power AC-3 (Pe): (220 / 230 / 240 V) 30 kW (380 / 400 V) 55 kW (440 V) 75 kW (415 V) 55 kW
- Rated Breaking Capacity AC-3 acc. to IEC 60947-4-1: 8 x Ie AC-3
- Rated Making Capacity AC-3 acc. to IEC 60947-4-1: 10 x Ie AC-3
- Short-Circuit Protective Devices: gG Type Fuses 200 A
Santa Clara Systems specializes in hard-to-find parts. Choose from our overstock inventory and save on 1SFL427102R1322 . Santa Clara Systems carries 36,195 items from ABB.
- 50/60 Hz And Dc
Alternates
- AF116-40-22B-13
- AF116 40 22B 13
- AF1164022B13
Common Typos
- 1SFL427102R132Z
- 1SFL427102R13Z2
- 1SFL427102R13ZZ
- 1SFL427102RI322
- 1SFL427102RI32Z
- 1SFL427102RI3Z2
- 1SFL427102RI3ZZ
- 1SFL427102RL322
- 1SFL427102RL32Z
- 1SFL427102RL3Z2
- 1SFL427102RL3ZZ
- 1SFL42710ZR1322
- 1SFL42710ZR132Z
- 1SFL42710ZR13Z2
- 1SFL42710ZR13ZZ
- 1SFL42710ZRI322
- 1SFL42710ZRI32Z
- 1SFL42710ZRI3Z2
- 1SFL42710ZRI3ZZ
- 1SFL42710ZRL322
- 1SFL42710ZRL32Z
- 1SFL42710ZRL3Z2
- 1SFL42710ZRL3ZZ
- 1SFL4271O2R1322
- 1SFL4271O2R132Z
Appended Numbers
- 1SFL427102R1322-A
- 1SFL427102R1322-B
- 1SFL427102R1322-C
- 1SFL427102R1322-D
- 1SFL427102R1322-E
- 1SFL427102R1322-F
- 1SFL427102R1322-G
- 1SFL427102R1322-H
- 1SFL427102R1322-I
- 1SFL427102R1322-J
- 1SFL427102R1322-K
- 1SFL427102R1322-L
- 1SFL427102R1322-M
- 1SFL427102R1322-N
- 1SFL427102R1322-O
- 1SFL427102R1322-P
- 1SFL427102R1322-Q
- 1SFL427102R1322-R
- 1SFL427102R1322-S
- 1SFL427102R1322-T
- 1SFL427102R1322-U
- 1SFL427102R1322-V
- 1SFL427102R1322-W
- 1SFL427102R1322-X
- 1SFL427102R1322-Y
- 1SFL427102R1322-Z
More Products Like This
-
1SFL427102R1300
ABB
-
1SFL427102R1100
ABB
-
1SFL427102R1122
ABB
-
1SFL427102R1200
ABB
Customers Are Also Buying
-
872C-D2NP8-P3
Allen Bradley
-
LC1D09BD
Telemecanique
-
440K-C21055
Allen Bradley
-
6ES7 971-1AA00-0AA0 (BATTERY)
Siemens
We Deliver!

- ✓ Late West Coast Shipping (5PM PST)
- ✓ Drop-Ship and Blind-Ship Specialists
- ✓ Expertly Packed Static-Limited
- ✓ Same-Day Service
- ✓ In-House Courier Domestic and International