• ABB 1SFL477001R6922 AF145-30-22 48-130V 50/60Hz / 48-130V DC Contactor Product Image
  • Abb 1SFL477001R6922 Barcode

1SFL477001R6922

Product Summary:

  • Extended Product Type: AF145-30-22 48-130V 50/60Hz / 48-130V DC
  • Product ID: 1SFL477001R6922
  • EAN: 7320500222669
  • Minimum Order Quantity: 1 piece
  • Customs Tariff Number: 85364900
Let Us Find It
           or           
  • Description: AF145-30-22 48-130V 50/60Hz / 48-130V DC Contactor
  • Mechanical Durability: 5 million
  • Maximum Mechanical Switching Frequency: 300 cycles per hour
  • Coil Operating Limits: (acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at ? ? 70 °C) °C
  • Rated Control Circuit Voltage (Uc): 60 Hz 48 130 V 50 Hz 48 130 V DC Operation 48 130 V
  • Coil Consumption: Pull-in at Max. Rated Control Circuit Voltage 60 Hz 430 V·A Holding at Max. Rated Control Circuit Voltage DC 2 W Holding at Max. Rated Control Circuit Voltage 50 Hz 12 V·A Pull-in at Max. Rated Control Circuit Voltage DC 500 W Pull-in at Max. Rated Control Circuit Voltage 50 Hz 430 V·A Holding at Max. Rated Control Circuit Voltage 60 Hz 12 V·A
  • Operate Time: Between Coil Energization and NO Contact Closing 50 ... 90 ms Between Coil De-energization and NO Contact Opening 43 ... 53 ms Between Coil De-energization and NC Contact Closing 40 .... 50 ms Between Coil Energization and NC Contact Opening 45 ... 85 ms
  • Connecting Capacity Main Circuit: Rigid Al-Cable 1x25150 mm² Bar 24 mm Rigid Cu-Cable 1x6185 mm²
  • Connecting Capacity Auxiliary Circuit: Solid 2x14 mm² Flexible with Insulated Ferrule 2x0.752.5 mm² Stranded 1x14 mm² Flexible 2x0.752.5 mm² Flexible with Ferrule 2x0.752.5 mm²
  • Degree of Protection: acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
  • Terminal Type: Main Circuit: Bars
  • Number of Main Contacts NO: 3
  • Maximum Operating Altitude Permissible: 3000 m
  • Resistance to Shock acc. to IEC 60068-2-27: Shock Direction: A 5 g Shock Direction: C2 5 g Shock Direction: C1 5 g Shock Direction: B2 5 g Shock Direction: B1 5 g
  • RoHS Status: Following EU Directive 2002/95/EC August 18, 2005 and amendment
  • Ambient Air Temperature: Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25+50 °C Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40+70 °C Close to Contactor for Storage -40+70 °C
  • General Use Rating UL/CSA: (600 V AC) 230 A
  • Horsepower Rating UL/CSA: (208 V AC) Three Phase 40 Hp (440 ... 480 V AC) Three Phase 100 Hp (550 ... 600 V AC) Three Phase 125 Hp (220 ... 240 V AC) Three Phase 50 Hp (200 V AC) Three Phase 40 Hp
  • Maximum Operating Voltage UL/CSA: Main Circuit 600 V
  • Instructions and Manuals: 1SFC380003-89
  • BV Certificate: 13409/C0 BV
  • CB Certificate: SE-69478
  • CCC Certificate: CQC_2007010304256685
  • Data Sheet, Technical Information: 1SBC100122C0202
  • Declaration of Conformity - CE: 1SFA1-61
  • GL Certificate: GL_20261-04HH
  • LOVAG Certificate: SE-0105160
  • LR Certificate: LR_04-00015-E1
  • RINA Certificate: ELE060313XG/002
  • RMRS Certificate: RMRS_12-03683-315
  • RoHS Information: 1SFC101055D0202
  • ETIM 4: EC000066 - Magnet contactor, AC-switching
  • ETIM 5: EC000066 - Magnet contactor, AC-switching
  • UNSPSC: 39121529
  • Object Classification Code: Q
  • Extended Product Type: AF145-30-22 48-130V 50/60Hz / 48-130V DC
  • Product ID: 1SFL477001R6922
  • EAN: 7320500222669
  • Minimum Order Quantity: 1 piece
  • Customs Tariff Number: 85364900
  • EAN: 7320500222669
  • Product Net Depth: 160.0 mm
  • Product Net Height: 196.0 mm
  • Product Net Weight: 3.600 kg
  • Product Net Width: 111.5 mm
  • Package Level 1 Width: 170 mm
  • Package Level 1 Length: 180 mm
  • Package Level 1 Height: 245 mm
  • Package Level 1 Gross Weight: 3.6 kg
  • Package Level 1 EAN: 7320500222669
  • Package Level 1 Units: 1 piece
  • Number of Main Contacts NC: 0
  • Number of Auxiliary Contacts NO: 2
  • Number of Auxiliary Contacts NC: 2
  • Rated Operational Voltage: Main Circuit 690 V
  • Rated Frequency (f): Main Circuit 50/60 Hz
  • Conventional Free-air Thermal Current (Ith): acc. to IEC 60947-4-1, Open Contactors q = 40 °C 250 A
  • Rated Operational Current AC-1 (Ie): (690 V) 55 °C 230 A (690 V) 40 °C 250 A (1000 V) 40 °C 180 A (1000 V) 55 °C 180 A (690 V) 70 °C 180 A (1000 V) 70 °C 180 A
  • Rated Operational Current AC-3 (Ie): (1000 V) 55 °C 80 A (220 / 230 / 240 V) 55 °C 145 A (415 V) 55 °C 145 A (690 V) 55 °C 120 A (440 V) 55 °C 145 A (380 / 400 V) 55 °C 145 A (500 V) 55 °C 145 A
  • Rated Operational Power AC-3 (Pe): (500 V) 90 kW (690 V) 110 kW (220 / 230 / 240 V) 45 kW (380 / 400 V) 75 kW (440 V) 75 kW (415 V) 75 kW
  • Rated Breaking Capacity AC-3 acc. to IEC 60947-4-1: 8 x Ie AC-3
  • Rated Making Capacity AC-3 acc. to IEC 60947-4-1: 10 x Ie AC-3
  • Short-Circuit Protective Devices: gG Type Fuses 315 A
  • Rated Short-time Withstand Current (Icw): at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 280 A at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 1200 A at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 800 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1800 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 600 A
  • Maximum Breaking Capacity: cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1500 A cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 1200 A
  • Maximum Electrical Switching Frequency: AC-3 300 cycles per hour AC-1 300 cycles per hour AC-2 / AC-4 150 cycles per hour
  • Rated Operational Current DC-1 (Ie): (110 V) 2 Poles in Series, 40 °C 250 A (220 V) 3 Poles in Series, 40 °C 250 A
  • Rated Operational Current DC-3 (Ie): (110 V) 2 Poles in Series, 40 °C 250 A (220 V) 3 Poles in Series, 40 °C 250 A
  • Rated Operational Current DC-5 (Ie): (110 V) 2 Poles in Series, 40 °C 250 A (220 V) 3 Poles in Series, 40 °C 250 A
  • Rated Insulation Voltage (Ui): acc. to UL/CSA 600 V acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V
  • Rated Impulse Withstand Voltage (Uimp): Main Circuit 8 kV
Santa Clara Systems specializes in hard-to-find parts. Choose from our overstock inventory and save on 1SFL477001R6922 . Santa Clara Systems carries 35,877 items from ABB.
  • Ac/Dc
  • A 3-Phase Contactor Suitable For Various Applications Such As Motor Starting
  • Isolation
  • By-Pass And Distribution Application Up To Max 1000 V. Operated With Wide Control Voltage Range 48-130 V
  • Alternates

    • AF145-30-22-69
    • AF145 30 22 69
    • AF145302269

    Common Typos

    • 1SFL477001R692Z
    • 1SFL477001R69Z2
    • 1SFL477001R69ZZ
    • 1SFL477001RG922
    • 1SFL477001RG92Z
    • 1SFL477001RG9Z2
    • 1SFL477001RG9ZZ
    • 1SFL47700IR6922
    • 1SFL47700IR692Z
    • 1SFL47700IR69Z2
    • 1SFL47700IR69ZZ
    • 1SFL47700IRG922
    • 1SFL47700IRG92Z
    • 1SFL47700IRG9Z2
    • 1SFL47700IRG9ZZ
    • 1SFL47700LR6922
    • 1SFL47700LR692Z
    • 1SFL47700LR69Z2
    • 1SFL47700LR69ZZ
    • 1SFL47700LRG922
    • 1SFL47700LRG92Z
    • 1SFL47700LRG9Z2
    • 1SFL47700LRG9ZZ
    • 1SFL4770O1R6922
    • 1SFL4770O1R692Z

    Appended Numbers

    • 1SFL477001R6922-A
    • 1SFL477001R6922-B
    • 1SFL477001R6922-C
    • 1SFL477001R6922-D
    • 1SFL477001R6922-E
    • 1SFL477001R6922-F
    • 1SFL477001R6922-G
    • 1SFL477001R6922-H
    • 1SFL477001R6922-I
    • 1SFL477001R6922-J
    • 1SFL477001R6922-K
    • 1SFL477001R6922-L
    • 1SFL477001R6922-M
    • 1SFL477001R6922-N
    • 1SFL477001R6922-O
    • 1SFL477001R6922-P
    • 1SFL477001R6922-Q
    • 1SFL477001R6922-R
    • 1SFL477001R6922-S
    • 1SFL477001R6922-T
    • 1SFL477001R6922-U
    • 1SFL477001R6922-V
    • 1SFL477001R6922-W
    • 1SFL477001R6922-X
    • 1SFL477001R6922-Y
    • 1SFL477001R6922-Z

    Customers Are Also Buying

    We Deliver!

    Late West Coast Shipping Hours
    Late West Coast Shipping (5PM PST)
    Drop-Ship and Blind-Ship Specialists
    Expertly Packed Static-Limited
    Same-Day Service
    In-House Courier Domestic and International
    visa credit card logo mastercard credit card logo discover credit card logo american express credit card logo