• ABB AF190-30-00-11 AF190-30-00-11 Contactor Product Image
  • Abb AF190-30-00-11 Barcode

AF190-30-00-11

Let Us Find It

Current response time:

By 5AM PT on Tuesday
  • Description: AF190-30-00-11 Contactor
  • Product ID: 1SFL487002R1100
  • Extended Product Type: 1SFL487002R1100
  • Product Net Weight: 2.740 kg
  • Product Net Width: 105.0 mm
  • Product Net Height: 196.0 mm
  • Product Net Depth: 152.0 mm
  • Degree of Protection: acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
  • Ambient Air Temperature: Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25+50 C Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40+70 C Close to Contactor for Storage -40+70 C
  • Rated Impulse Withstand Voltage (U<sub>imp</sub>): Main Circuit 8 kV
  • Rated Insulation Voltage (U<sub>i</sub>): acc. to UL/CSA 600 V acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V
  • Terminal Type: Main Circuit: Bars
  • Rated Frequency (f): Main Circuit 50/60 Hz
  • Number of Auxiliary Contacts NO: 0
  • Number of Auxiliary Contacts NC: 0
  • Mechanical Durability: 5 million
  • Connecting Capacity Main Circuit: Rigid Al-Cable 1x95185 mm Flexible 2x5095 mm Rigid Cu-Cable 1x6150 mm
  • Maximum Operating Voltage UL/CSA: Main Circuit 600 V
  • Maximum Operating Altitude Permissible: 3000 m
  • Rated Control Circuit Voltage (U<sub>c</sub>): 60 Hz 2460 V 50 Hz 2460 V DC Operation 2060 V
  • Maximum Mechanical Switching Frequency: 300 cycles per hour
  • Connecting Capacity Auxiliary Circuit: Solid 2x14 mm Flexible with Insulated Ferrule 1x0.752.5 mm Stranded 2x14 mm Flexible 2x0.752.5 mm Flexible with Ferrule 1x0.752.5 mm
  • Operate Time: Between Coil Energization and NO Contact Closing 2555 ms Between Coil De-energization and NO Contact Opening 3747 ms
  • Number of Main Contacts NO: 3
  • Number of Main Contacts NC: 0
  • Short-Circuit Protective Devices: gG Type Fuses 355 A
  • Maximum Breaking Capacity: cos phi=0.45 (cos phi=0.35 for Ie &gt; 100 A) at 440 V 3300 A cos phi=0.45 (cos phi=0.35 for Ie &gt; 100 A) at 690 V 2200 A
  • Coil Consumption: Pull-in at Max. Rated Control Circuit Voltage 60 Hz 165 V&#183;A Holding at Max. Rated Control Circuit Voltage DC 2.5 W Holding at Max. Rated Control Circuit Voltage 50 Hz 6 V&#183;A Pull-in at Max. Rated Control Circuit Voltage DC 205 W Pull-in at Max. Rated Control Circuit Voltage 50 Hz 165 V&#183;A Holding at Max. Rated Control Circuit Voltage 60 Hz 6 V&#183;A
  • Coil Operating Limits: (acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at 70 C) C
  • Horsepower Rating UL/CSA: (208 V AC) Three Phase 50 Hp (440 ... 480 V AC) Three Phase 125 Hp (550 ... 600 V AC) Three Phase 150 Hp (220 ... 240 V AC) Three Phase 60 Hp (200 V AC) Three Phase 50 Hp
  • General Use Rating UL/CSA: (600 V AC) 250 A
  • EAN: 7320500480373
  • Minimum Order Quantity: 1 piece
  • Customs Tariff Number: 85364900
  • Package Level 1 Width: 223 mm
  • Package Level 1 Length: 133 mm
  • Package Level 1 Height: 186 mm
  • Package Level 1 Gross Weight: 3.19 kg
  • Package Level 1 EAN: 7320500480373
  • Package Level 1 Units: 1 piece
  • Rated Operational Voltage: Main Circuit 1000 V
  • Conventional Free-air Thermal Current (I<sub>th</sub>): acc. to IEC 60947-4-1, Open Contactors q = 40 C 275 A
  • Rated Operational Current AC-1 (I<sub>e</sub>): (690 V) 55 C 250 A (690 V) 40 C 275 A (1000 V) 40 C 250 A (1000 V) 55 C 225 A (690 V) 70 C 200 A (1000 V) 70 C 185 A
  • Rated Operational Current AC-3 (I<sub>e</sub>): (1000 V) 55 C 85 A (415 V) 55 C 190 A (220 / 230 / 240 V) 55 C 190 A (690 V) 55 C 135 A (440 V) 55 C 190 A (380 / 400 V) 55 C 190 A (500 V) 55 C 135 A
  • Rated Operational Power AC-3 (P<sub>e</sub>): (500 V) 90 kW (1000 V) 110 kW (690 V) 132 kW (220 / 230 / 240 V) 55 kW (380 / 400 V) 90 kW (440 V) 110 kW (415 V) 90 kW
  • Rated Breaking Capacity AC-3 acc. to IEC 60947-4-1: 8 x Ie AC-3
  • Rated Making Capacity AC-3 acc. to IEC 60947-4-1: 10 x Ie AC-3
  • Rated Short-time Withstand Current (I<sub>cw</sub>): at 40 C Ambient Temp, in Free Air, from a Cold State 15 min 275 A at 40 C Ambient Temp, in Free Air, from a Cold State 10 s 1520 A at 40 C Ambient Temp, in Free Air, from a Cold State 30 s 878 A at 40 C Ambient Temp, in Free Air, from a Cold State 1 s 1900 A at 40 C Ambient Temp, in Free Air, from a Cold State 1 min 621 A
  • Maximum Electrical Switching Frequency: AC-3 300 cycles per hour AC-1 300 cycles per hour AC-2 / AC-4 150 cycles per hour
  • Rated Operational Current DC-1 (I<sub>e</sub>): (110 V) 2 Poles in Series, 40 C 250 A (220 V) 3 Poles in Series, 40 C 250 A
  • Rated Operational Current DC-3 (I<sub>e</sub>): (110 V) 2 Poles in Series, 40 C 250 A (220 V) 3 Poles in Series, 40 C 250 A
  • Rated Operational Current DC-5 (I<sub>e</sub>): (110 V) 2 Poles in Series, 40 C 250 A (220 V) 3 Poles in Series, 40 C 250 A
  • RoHS Status: Following EU Directive 2002/95/EC August 18, 2005 and amendment
  • Instructions and Manuals: 1SFC100008M0201
  • CB Certificate: SE-71797M1
  • Data Sheet, Technical Information: 1SFC101070D0201
  • Declaration of Conformity - CE: 2CMT004613
  • RINA Certificate: ELE060313XG/002
  • RoHS Information: 1SFC101055D0202
  • E-nummer: 3210128
  • ETIM 4: EC000066 - Magnet contactor, AC-switching
  • ETIM 5: EC000066 - Magnet contactor, AC-switching
  • UNSPSC: 39121529
  • Object Classification Code: Q
Santa Clara Systems specializes in hard-to-find parts. Choose from our overstock inventory and save on AF190-30-00-11 . Santa Clara Systems carries 36,673 items from ABB.
  • 50 And 60 Hz
  • 20-60 V Dc
  • A 3-Phase Contactor Suitable For Various Applications Such As Motor Starting
  • Isolation
  • By-Pass And Distribution Application Up To Max 1000 V. Operated With Wide Control Voltage Range 24-60 V

Alternates

  • 1SFL487002R1100
  • AF190 30 00 11
  • AF190300011

Common Typos

  • AF190-30-00-1I
  • AF190-30-00-1L
  • AF190-30-00-I1
  • AF190-30-00-II
  • AF190-30-00-IL
  • AF190-30-00-L1
  • AF190-30-00-LI
  • AF190-30-00-LL
  • AF190-30-0O-11
  • AF190-30-0O-1I
  • AF190-30-0O-1L
  • AF190-30-0O-I1
  • AF190-30-0O-II
  • AF190-30-0O-IL
  • AF190-30-0O-L1
  • AF190-30-0O-LI
  • AF190-30-0O-LL
  • AF190-30-O0-11
  • AF190-30-O0-1I
  • AF190-30-O0-1L
  • AF190-30-O0-I1
  • AF190-30-O0-II
  • AF190-30-O0-IL
  • AF190-30-O0-L1
  • AF190-30-O0-LI
  • AF190-30-O0-LL

Appended Numbers

  • AF190-30-00-11-A
  • AF190-30-00-11-B
  • AF190-30-00-11-C
  • AF190-30-00-11-D
  • AF190-30-00-11-E
  • AF190-30-00-11-F
  • AF190-30-00-11-G
  • AF190-30-00-11-H
  • AF190-30-00-11-I
  • AF190-30-00-11-J
  • AF190-30-00-11-K
  • AF190-30-00-11-L
  • AF190-30-00-11-M
  • AF190-30-00-11-N
  • AF190-30-00-11-O
  • AF190-30-00-11-P
  • AF190-30-00-11-Q
  • AF190-30-00-11-R
  • AF190-30-00-11-S
  • AF190-30-00-11-T
  • AF190-30-00-11-U
  • AF190-30-00-11-V
  • AF190-30-00-11-W
  • AF190-30-00-11-X
  • AF190-30-00-11-Y
  • AF190-30-00-11-Z

Customers Are Also Buying

We Deliver!

Late West Coast Shipping Hours
Late West Coast Shipping (5PM PST)
Drop-Ship and Blind-Ship Specialists
Expertly Packed Static-Limited
Same-Day Service
In-House Courier
visa credit card logo mastercard credit card logo discover credit card logo american express credit card logo

Customers we work with

3M logo
Kaiser Permanente logo
Safeway Logo
Georgia-Pacific logo
Coca Cola logo
duke energy logo
BART logo
Pepsi logo
LA DWP logo
US Navy logo
Dean Foods logo
ConAgra Brands logo