Product Summary:
- Extended Product Type: AF460-30-22 24-60V DC
- Product ID: 1SFL597001R6822
- EAN: 7320500217917
- Minimum Order Quantity: 1 piece
- Customs Tariff Number: 85364900
Let Us Find It
or
CALL 1 (888) 450-0301
- Description: AF460-30-22 24-60V DC Contactor
- Mechanical Durability: 5 million
- Maximum Mechanical Switching Frequency: 300 cycles per hour
- Coil Operating Limits: (acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at ? ? 70 °C) °C
- Rated Control Circuit Voltage (Uc): DC Operation 24 60 V
- Coil Consumption: Pull-in at Max. Rated Control Circuit Voltage 60 Hz 900 V·A Holding at Max. Rated Control Circuit Voltage DC 5 V·A Holding at Max. Rated Control Circuit Voltage 50 Hz 12 V·A Pull-in at Max. Rated Control Circuit Voltage DC 900 V·A Pull-in at Max. Rated Control Circuit Voltage 50 Hz 900 V·A Holding at Max. Rated Control Circuit Voltage 60 Hz 12 V·A
- Operate Time: Between Coil Energization and NO Contact Closing 50 ... 120 ms Between Coil De-energization and NO Contact Opening 48 ... 58 ms Between Coil De-energization and NC Contact Closing 45 ... 55 ms Between Coil Energization and NC Contact Opening 45 ... 115 ms
- Connecting Capacity Main Circuit: Rigid Al-Cable 2x240 mm² Bar 47 mm Rigid Cu-Cable 240 mm²
- Connecting Capacity Auxiliary Circuit: Solid 2x14 mm² Flexible with Insulated Ferrule 2x0.752.5 mm² Stranded 2x14 mm² Flexible 2x0.752.5 mm² Flexible with Ferrule 2x0.752.5 mm²
- Degree of Protection: acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
- Terminal Type: Main Circuit: Bars
- Number of Main Contacts NO: 3
- Maximum Operating Altitude Permissible: 3000 m
- Resistance to Shock acc. to IEC 60068-2-27: Shock Direction: A 5 g Shock Direction: C2 5 g Shock Direction: B2 5 g Shock Direction: C1 5 g Shock Direction: B1 5 g
- RoHS Status: Following EU Directive 2002/95/EC August 18, 2005 and amendment
- Ambient Air Temperature: Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25+50 °C Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40+70 °C Close to Contactor for Storage -40+70 °C
- General Use Rating UL/CSA: (600 V AC) 650 A
- Horsepower Rating UL/CSA: (208 V AC) Three Phase 150 Hp (440 ... 480 V AC) Three Phase 400 Hp (550 ... 600 V AC) Three Phase 500 Hp (220 ... 240 V AC) Three Phase 200 Hp (200 V AC) Three Phase 150 Hp
- Maximum Operating Voltage UL/CSA: Main Circuit 600 V
- Instructions and Manuals: 1SFC380023-en
- BV Certificate: 11727/C0 BV
- CB Certificate: SE-69485
- CCC Certificate: CQC_2007010304256683
- CSA Certificate: 306711
- Data Sheet, Technical Information: 1SBC100122C0202
- Declaration of Conformity - CE: 1SFA1-65
- DNV Certificate: DNV_E-10966
- GL Certificate: GL_42988-02HH
- LOVAG Certificate: SE-200438
- LR Certificate: LR_13_20009
- RINA Certificate: ELE060313XG/002
- RoHS Information: 1SFC101055D0202
- ETIM 4: EC000066 - Magnet contactor, AC-switching
- ETIM 5: EC000066 - Magnet contactor, AC-switching
- UNSPSC: 39121529
- Object Classification Code: Q
- Extended Product Type: AF460-30-22 24-60V DC
- Product ID: 1SFL597001R6822
- EAN: 7320500217917
- Minimum Order Quantity: 1 piece
- Customs Tariff Number: 85364900
- EAN: 7320500217917
- Product Net Depth: 216.0 mm
- Product Net Height: 278.0 mm
- Product Net Weight: 12.000 kg
- Product Net Width: 186.0 mm
- Package Level 1 Width: 260 mm
- Package Level 1 Length: 250 mm
- Package Level 1 Height: 350 mm
- Package Level 1 Gross Weight: 12 kg
- Package Level 1 EAN: 7320500217917
- Package Level 1 Units: 1 piece
- Number of Main Contacts NC: 0
- Number of Auxiliary Contacts NO: 2
- Number of Auxiliary Contacts NC: 2
- Rated Operational Voltage: Main Circuit 1000 V
- Rated Frequency (f): Main Circuit 50 Hz Main Circuit 60 Hz
- Conventional Free-air Thermal Current (Ith): acc. to IEC 60947-4-1, Open Contactors q = 40 °C 700 A
- Rated Operational Current AC-1 (Ie): (690 V) 55 °C 600 A (690 V) 40 °C 700 A (1000 V) 40 °C 700 A (1000 V) 55 °C 600 A (690 V) 70 °C 480 A (1000 V) 70 °C 480 A
- Rated Operational Current AC-3 (Ie): (1000 V) 55 °C 200 A (415 V) 55 °C 460 A (220 / 230 / 240 V) 55 °C 460 A (690 V) 55 °C 400 A (440 V) 55 °C 460 A (380 / 400 V) 55 °C 460 A (500 V) 55 °C 460 A
- Rated Operational Power AC-3 (Pe): (500 V) 315 kW (690 V) 355 kW (220 / 230 / 240 V) 132 kW (380 / 400 V) 250 kW (440 V) 250 kW (415 V) 250 kW
- Rated Breaking Capacity AC-3 acc. to IEC 60947-4-1: 8 x Ie AC-3
- Rated Making Capacity AC-3 acc. to IEC 60947-4-1: 10 x Ie AC-3
- Short-Circuit Protective Devices: gG Type Fuses 800 A
- Rated Short-time Withstand Current (Icw): at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 4400 A at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 3100 A at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 840 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 4600 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 2500 A
- Maximum Breaking Capacity: cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 5000 A cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 4500 A
- Maximum Electrical Switching Frequency: AC-3 300 cycles per hour AC-1 300 cycles per hour AC-2 / AC-4 60 cycles per hour
- Rated Operational Current DC-1 (Ie): (600 V) 3 Poles in Series, 40 °C 700 A (110 V) 1-Pole, 40 °C 700 A (110 V) 2 Poles in Series, 40 °C 700 A (220 V) 3 Poles in Series, 40 °C 700 A
- Rated Operational Current DC-3 (Ie): (600 V) 3 Poles in Series, 40 °C 700 A (110 V) 1-Pole, 40 °C 700 A (110 V) 2 Poles in Series, 40 °C 700 A (220 V) 3 Poles in Series, 40 °C 700 A
- Rated Operational Current DC-5 (Ie): (600 V) 3 Poles in Series, 40 °C 700 A (110 V) 1-Pole, 40 °C 700 A (110 V) 2 Poles in Series, 40 °C 700 A (220 V) 3 Poles in Series, 40 °C 700 A
- Rated Insulation Voltage (Ui): acc. to UL/CSA 600 V acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V
- Rated Impulse Withstand Voltage (Uimp): Main Circuit 8 kV
Santa Clara Systems specializes in hard-to-find parts. Choose from our overstock inventory and save on 1SFL597001R6822 . Santa Clara Systems carries 36,195 items from ABB.
- Dc
Alternates
- AF460-30-22-68
- AF460 30 22 68
- AF460302268
Common Typos
- 1SFL597001R682Z
- 1SFL597001R68Z2
- 1SFL597001R68ZZ
- 1SFL597001R6B22
- 1SFL597001R6B2Z
- 1SFL597001R6BZ2
- 1SFL597001R6BZZ
- 1SFL597001RG822
- 1SFL597001RG82Z
- 1SFL597001RG8Z2
- 1SFL597001RG8ZZ
- 1SFL597001RGB22
- 1SFL597001RGB2Z
- 1SFL597001RGBZ2
- 1SFL597001RGBZZ
- 1SFL59700IR6822
- 1SFL59700IR682Z
- 1SFL59700IR68Z2
- 1SFL59700IR68ZZ
- 1SFL59700IR6B22
- 1SFL59700IR6B2Z
- 1SFL59700IR6BZ2
- 1SFL59700IR6BZZ
- 1SFL59700IRG822
- 1SFL59700IRG82Z
Appended Numbers
- 1SFL597001R6822-A
- 1SFL597001R6822-B
- 1SFL597001R6822-C
- 1SFL597001R6822-D
- 1SFL597001R6822-E
- 1SFL597001R6822-F
- 1SFL597001R6822-G
- 1SFL597001R6822-H
- 1SFL597001R6822-I
- 1SFL597001R6822-J
- 1SFL597001R6822-K
- 1SFL597001R6822-L
- 1SFL597001R6822-M
- 1SFL597001R6822-N
- 1SFL597001R6822-O
- 1SFL597001R6822-P
- 1SFL597001R6822-Q
- 1SFL597001R6822-R
- 1SFL597001R6822-S
- 1SFL597001R6822-T
- 1SFL597001R6822-U
- 1SFL597001R6822-V
- 1SFL597001R6822-W
- 1SFL597001R6822-X
- 1SFL597001R6822-Y
- 1SFL597001R6822-Z
More Products Like This
-
1SFL597001R6922
ABB
-
1SFL597001R6811
ABB
-
1SFL597001R7022
ABB
-
1SFL597001R7122
ABB
Customers Are Also Buying
-
Q6BAT (BATTERY)
Mitsubishi
-
872C-A5N18-A5
Allen Bradley
-
800FP-POT6
Allen Bradley
-
3RH1 921-1CA01
Siemens
We Deliver!

- ✓ Late West Coast Shipping (5PM PST)
- ✓ Drop-Ship and Blind-Ship Specialists
- ✓ Expertly Packed Static-Limited
- ✓ Same-Day Service
- ✓ In-House Courier Domestic and International