A9-30-10-80

Product Summary:

  • Extended Product Type: A9-30-10 220-230V 50Hz / 230-240V 60Hz
  • Product ID: 1SBL141001T8010
  • EAN: 3471522037800
  • Minimum Order Quantity: 10 piece
  • Customs Tariff Number: 85369085
Let Us Find It
           or           
  • Description: Contactor
  • Rated Control Circuit Voltage (Uc): 50 Hz 220 230 V 60 Hz 230 240 V
  • Coil Consumption: Average Holding Value 50 / 60 Hz 8 V·A Average Holding Value 50 / 60 Hz 2 W Average Pull-in Value 50 Hz 74 V·A Average Pull-in Value 60 Hz 70 V·A
  • Operate Time: Between Coil Energization and NO Contact Closing 10 ... 26 ms Between Coil De-energization and NO Contact Opening 4 ... 11 ms
  • Connecting Capacity Main Circuit: Rigid Cable 1 ... 4 mm² Flexible with Cable End 0.75 ... 2.5 mm²
  • Connecting Capacity Auxiliary Circuit: Rigid Cable 1 ... 4 mm² Flexible with Cable End 0.75 ... 2.5 mm²
  • Degree of Protection: acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20
  • Connecting terminals (delivered in open position) Main poles: M 3.5 (+,-) pozidriv 2 screws with cable clamp
  • Terminal Type: Screw Terminals
  • Number of Main Contacts NO: 3
  • Climatic Withstand: acc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II
  • Maximum Operating Altitude Permissible: 3000 m
  • Resistance to Shock acc. to IEC 60068-2-27: Shock Direction: A 20 g Closed, Shock Direction: B1 10 g Open, Shock Direction: B1 5 g Shock Direction: B2 15 g Shock Direction: C1 20 g Shock Direction: C2 20 g
  • RoHS Status: Following EU Directive 2002/95/EC August 18, 2005 and amendment
  • Ambient Air Temperature: Close to Contactor Fitted with Thermal O/L Relay -25 ... +55 °C Close to Contactor for Storage -60 ... +80 °C Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... +55 °C Close to Contactor without Thermal O/L Relay (Uc) -40 ... +70 °C
  • Instructions and Manuals: FPTC407721P0001
  • BV Certificate: BV_2634H07559D0
  • CB Certificate: CB_FR_602227A
  • CCC Certificate: CCC_2013010304615753 CCC_2004010309130463
  • CSA Certificate: CSA_1041746
  • cUL Certificate: UL_20160205-E312527-10-2
  • Data Sheet, Technical Information: 1SBC100122C0202_Ch02
  • Declaration of Conformity - CE: 1SBD250801U1000
  • DNV Certificate: DNV-GL_TAE00000TX
  • EAC Certificate: EAC_RU C-FR ME77 B01010
  • GL Certificate: DNV-GL_TAE00000TX
  • GOST Certificate: GOST_POCCFRME77B07175
  • LOVAG Certificate: LOVAG_FR97037
  • LR Certificate: LRS_9830011E4
  • RINA Certificate: RINA_ELE128713XG001
  • RMRS Certificate: RMRS_0507015250
  • RoHS Information: 1SBD350050R1000
  • UL Certificate: UL_071301E39231
  • UL Listing Card: UL_E312527
  • ETIM 4: EC000066 - Magnet contactor, AC-switching
  • ETIM 5: EC000066 - Magnet contactor, AC-switching
  • ETIM 6: EC000066 - Power contactor, AC switching
  • UNSPSC: 39121529
  • Object Classification Code: Q
  • Extended Product Type: A9-30-10 220-230V 50Hz / 230-240V 60Hz
  • Product ID: 1SBL141001T8010
  • EAN: 3471522037800
  • Minimum Order Quantity: 10 piece
  • Customs Tariff Number: 85369085
  • EAN: 3471522037800
  • Product Net Depth: 74 mm
  • Product Net Height: 74 mm
  • Product Net Weight: 0.340 kg
  • Product Net Width: 44 mm
  • Package Level 1 Width: 159 mm
  • Package Level 1 Length: 250 mm
  • Package Level 1 Height: 85 mm
  • Package Level 1 Gross Weight: 3.4 kg
  • Package Level 1 EAN: 3471522037800
  • Package Level 2 Units: 10 piece
  • Package Level 3 Units: 1050 piece
  • Package Level 1 Units: 10 piece
  • Number of Main Contacts NC: 0
  • Number of Auxiliary Contacts NO: 1
  • Number of Auxiliary Contacts NC: 0
  • Standards: Devices complying with international standards IEC 947-1 / 947-4-1, and European standards EN 60 947-1 / 60 947-4-1. Electromagnetic compatibility (EMC) acc. to amendment A11 to IEC 947-1; EN 60 947-1 and amendment 2 to IEC 947-4-1
  • Rated Operational Voltage: Main Circuit 690 V
  • Rated Frequency (f): Supply Circuit 50 Hz Supply Circuit 60 Hz
  • Conventional Free-air Thermal Current (Ith): acc. to IEC 60947-4-1, Open Contactors q = 40 °C 26 A acc. to IEC 60947-5-1, q = 40 °C 16 A
  • Rated Operational Current AC-1 (Ie): (690 V) 40 °C 25 A (690 V) 55 °C 22 A (690 V) 70 °C 18 A
  • Rated Operational Power AC-3 (Pe): (220 / 230 / 240 V) 2.2 kW (380 / 400 V) 4 kW (415 V) 4 kW (440 V) 4 kW (500 V) 5.5 kW (690 V) 5.5 kW
  • Rated Breaking Capacity AC-3 acc. to IEC 60947-4-1: 8 x Ie AC-3
  • Rated Making Capacity AC-3 acc. to IEC 60947-4-1: 10 x Ie AC-3
  • Rated Operational Current AC-15 (Ie): (220 / 240 V) 4 A (24 / 127 V) 6 A (380 / 440 V) 3 A (500 V) 2 A (690 V) 2 A
  • Short-Circuit Protective Devices: Auxiliary Circuit - gG Type Fuses 10 A gG Type Fuses 25 A
  • Rated Short-time Withstand Current (Icw): at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 100 A at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 26 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 50 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 250 A at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 60 A for 0.1 s 140 A for 1 s 100 A
  • Maximum Breaking Capacity: cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 250 A cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 90 A
  • Maximum Electrical Switching Frequency: AC-1 600 cycles per hour AC-2 / AC-4 300 cycles per hour AC-3 1200 cycles per hour
  • Rated Operational Current DC-13 (Ie): (125 V) 1.1 / 138 A (24 V) 6 / 144 A (250 V) 0.55 / 138 A (48 V) 2.8 / 134 A (72 V) 2 / 144 A
  • Rated Insulation Voltage (Ui): acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V acc. to UL/CSA 600 V
  • Rated Impulse Withstand Voltage (Uimp): 8 kV
  • Mechanical Durability: 10 million
  • Maximum Mechanical Switching Frequency: 3600 cycles per hour
  • Coil Operating Limits: (acc. to IEC 60947-4-1) 0.85 ... 1.1 x Uc (at ? ? 55 °C) °C
Santa Clara Systems specializes in hard-to-find parts. Choose from our overstock inventory and save on A9-30-10-80 . Santa Clara Systems carries 35,866 items from ABB.
We are in the process of adding data and downloadable material for this item. Please search similar items for more information related to this product.

Alternates

  • A9-30-10-80

Common Typos

  • A9-30-10-8O
  • A9-30-10-B0
  • A9-30-10-BO
  • A9-30-1O-80
  • A9-30-1O-8O
  • A9-30-1O-B0
  • A9-30-1O-BO
  • A9-30-I0-80
  • A9-30-I0-8O
  • A9-30-I0-B0
  • A9-30-I0-BO
  • A9-30-IO-80
  • A9-30-IO-8O
  • A9-30-IO-B0
  • A9-30-IO-BO
  • A9-30-L0-80
  • A9-30-L0-8O
  • A9-30-L0-B0
  • A9-30-L0-BO
  • A9-30-LO-80
  • A9-30-LO-8O
  • A9-30-LO-B0
  • A9-30-LO-BO
  • A9-3O-10-80
  • A9-3O-10-8O

Appended Numbers

  • A9-30-10-80-A
  • A9-30-10-80-B
  • A9-30-10-80-C
  • A9-30-10-80-D
  • A9-30-10-80-E
  • A9-30-10-80-F
  • A9-30-10-80-G
  • A9-30-10-80-H
  • A9-30-10-80-I
  • A9-30-10-80-J
  • A9-30-10-80-K
  • A9-30-10-80-L
  • A9-30-10-80-M
  • A9-30-10-80-N
  • A9-30-10-80-O
  • A9-30-10-80-P
  • A9-30-10-80-Q
  • A9-30-10-80-R
  • A9-30-10-80-S
  • A9-30-10-80-T
  • A9-30-10-80-U
  • A9-30-10-80-V
  • A9-30-10-80-W
  • A9-30-10-80-X
  • A9-30-10-80-Y
  • A9-30-10-80-Z

More Products Like This

Customers Are Also Buying

We Deliver!

Late West Coast Shipping Hours
Late West Coast Shipping (5PM PST)
Drop-Ship and Blind-Ship Specialists
Expertly Packed Static-Limited
Same-Day Service
In-House Courier Domestic and International
visa credit card logo mastercard credit card logo discover credit card logo american express credit card logo