• ABB GAE75-10-11-89 GAE75-10-11 240V DC Contactor Product Image
  • Abb GAE75-10-11-89 Barcode

GAE75-10-11-89

Let Us Find It

Current response time:

6 Minutes 17 Seconds
  • Description: GAE75-10-11 240V DC Contactor
  • Product ID: 1SBL419025R8911
  • Extended Product Type: 1SBL419025R8911
  • Product Net Weight: 1.300 kg
  • Product Net Width: 94 mm
  • Product Net Height: 132 mm
  • Product Net Depth: 108 mm
  • Degree of Protection: acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20
  • Ambient Air Temperature: Near Contactor for Operation in Free Air (0.85 ... 1.1 Uc) -40 ... +55 C Near Contactor for Operation in Free Air (Uc) -40 ... +70 C Close to Contactor for Storage -60 ... +80 C
  • Rated Impulse Withstand Voltage (U<sub>imp</sub>): 8 kV
  • Rated Insulation Voltage (U<sub>i</sub>): acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V acc. to IEC 60947-5-1 and VDE 0110 (Gr. C) 690 V acc. to UL/CSA 600 V
  • Terminal Type: Screw Terminals
  • Rated Frequency (f): Supply Circuit 50 Hz Supply Circuit 60 Hz
  • Number of Auxiliary Contacts NO: 1
  • Number of Auxiliary Contacts NC: 1
  • Mechanical Durability: 5 million
  • Connecting Capacity Main Circuit: Flexible with Cable End 6 ... 16 mm Rigid Cable 6 ... 25 mm
  • GOST Certificate: GOST_POCCFRME77B07175
  • Maximum Operating Altitude Permissible: 3000 m
  • Rated Control Circuit Voltage (U<sub>c</sub>): DC Operation 240 V
  • Climatic Withstand: acc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II
  • Maximum Mechanical Switching Frequency: 3600 cycles per hour
  • Connecting Capacity Auxiliary Circuit: Flexible with Cable End 0.75 ... 2.5 mm Rigid Cable 1 ... 4 mm
  • Operate Time: Between Coil Energization and NO Contact Closing 30 ... 30 ms Between Coil De-energization and NO Contact Opening 5 ... 15 ms Between Coil De-energization and NC Contact Closing 8 ... 18 ms Between Coil Energization and NC Contact Opening 10 ... 27 ms
  • Number of Main Contacts NO: 1
  • Number of Main Contacts NC: 0
  • Short-Circuit Protective Devices: Auxiliary Circuit - gG Type Fuses 10 A gG Type Fuses 160 A
  • Coil Consumption: Average Holding Value, from Warm State 4 W Average Pull-in Value, from Cold State 200 W Holding at Max. Rated Control Circuit Voltage DC 4 W Pull-in at Max. Rated Control Circuit Voltage DC 200 W
  • Coil Operating Limits: (acc. to IEC 60947-4-1) 0.85 ... 1.1 x Uc (at 55 C) C
  • Connecting terminals (delivered in open position) Main poles: M 6 (+,-) pozidriv 2 screws with 1x (13 x 10 mm) connector
  • EAN: 3471522113894
  • Minimum Order Quantity: 1 piece
  • Customs Tariff Number: 85369085
  • Package Level 1 Width: 140 mm
  • Package Level 1 Length: 146 mm
  • Package Level 1 Height: 96 mm
  • Package Level 1 Gross Weight: 1.3 kg
  • Package Level 1 EAN: 3471522113894
  • Package Level 2 Units: 63 piece
  • Package Level 1 Units: 1 piece
  • Rated Operational Voltage: Main Circuit 600 V
  • Conventional Free-air Thermal Current (I<sub>th</sub>): acc. to IEC 60947-4-1, Open Contactors q = 40 C 125 A acc. to IEC 60947-5-1, q = 40 C 16 A
  • Rated Operational Current AC-15 (I<sub>e</sub>): (220 / 240 V) 4 A (24 / 127 V) 6 A (380 / 440 V) 3 A (500 V) 2 A (690 V) 2 A
  • Rated Short-time Withstand Current (I<sub>cw</sub>): at 40 C Ambient Temp, in Free Air, from a Cold State 10 s 650 A at 40 C Ambient Temp, in Free Air, from a Cold State 15 min 135 A at 40 C Ambient Temp, in Free Air, from a Cold State 1 min 250 A at 40 C Ambient Temp, in Free Air, from a Cold State 1 s 1000 A at 40 C Ambient Temp, in Free Air, from a Cold State 30 s 370 A for 0.1 s 140 A for 1 s 100 A
  • Maximum Electrical Switching Frequency: 300 cycles per hour
  • Rated Operational Current DC-1 (I<sub>e</sub>): (440 V) 55 C 100 A
  • Rated Operational Current DC-3 (I<sub>e</sub>): (440 V) 85 A
  • Rated Operational Current DC-5 (I<sub>e</sub>): (220 V) 85 A (440 V) 35 A
  • Rated Operational Current DC-13 (I<sub>e</sub>): (125 V) 0.55 / 69 A (24 V) 6 / 144 A (250 V) 0.3 / 75 A (48 V) 2.8 / 134 A (72 V) 1 / 72 A
  • RoHS Status: No declaration needed
  • Instructions and Manuals: FPTC407691P0003
  • CCC Certificate: CCC_2011010304454200
  • CSA Certificate: CSA_1033838_LR056745
  • Data Sheet, Technical Information: 1SBC100122C0202_Ch02
  • Declaration of Conformity - CE: 1SBD250807U1000
  • RoHS Information: 1SBC101059D0201
  • ETIM 4: EC002552 - Power contactor, DC switching
  • ETIM 5: EC002552 - Power contactor, DC switching
  • ETIM 6: EC002552 - Power contactor, DC switching
  • UNSPSC: 39121529
  • Object Classification Code: Q
Santa Clara Systems specializes in hard-to-find parts. Choose from our overstock inventory and save on GAE75-10-11-89 . Santa Clara Systems carries 36,673 items from ABB.
  • They Are Marked 1l1 For The Positive Terminal And 2t1 For The Negative Terminal. - Auxiliary Contact: 1 Cal 5-11 Side-Mounted Add-On Auxiliary Contact Block (Gae75-10-11 Types) - Control Circuit: Dc Operated With Standard Double-Winding Dc Coils (With Add-On Factory-Mounted Lagging Contact For Insertion Of The&quot;holding&quot; Winding) - Accessories: A Wide Range Of Accessories Is Available
  • Gae75 Contactors Are Designed For Dc Circuit Switching. Arc Suppression Is More Difficult In Dc Than In Ac. To Choose A Contactor
  • It Is Necessary To Know The Current And Voltage To Be Broken As Well As The L/r Time Constant Of The Power Circuit To Be Controlled. Gae 75 Contactors Are Of The Block Type Design. - Main Poles: The Contactors Are Fitted With Arc Chutes With Permanent Magnets Specially Designed For Dc Breaking. The Three Contactor Paths Are Arranged In Series Via Two Supplied And Fitted Insulated Connections (25 Mm&#178;). The Gae75 Are &quot;single-Pole&quot; Devices For Which The Connection Polarities Indicated Next To The Connection Terminals Must Be Respected. Furthermore

Alternates

  • 1SBL419025R8911
  • GAE75 10 11 89
  • GAE75101189

Common Typos

  • GAE75-10-11-B9
  • GAE75-10-1I-89
  • GAE75-10-1I-B9
  • GAE75-10-1L-89
  • GAE75-10-1L-B9
  • GAE75-10-I1-89
  • GAE75-10-I1-B9
  • GAE75-10-II-89
  • GAE75-10-II-B9
  • GAE75-10-IL-89
  • GAE75-10-IL-B9
  • GAE75-10-L1-89
  • GAE75-10-L1-B9
  • GAE75-10-LI-89
  • GAE75-10-LI-B9
  • GAE75-10-LL-89
  • GAE75-10-LL-B9
  • GAE75-1O-11-89
  • GAE75-1O-11-B9
  • GAE75-1O-1I-89
  • GAE75-1O-1I-B9
  • GAE75-1O-1L-89
  • GAE75-1O-1L-B9
  • GAE75-1O-I1-89
  • GAE75-1O-I1-B9
  • GAE75-1O-II-89

Appended Numbers

  • GAE75-10-11-89-A
  • GAE75-10-11-89-B
  • GAE75-10-11-89-C
  • GAE75-10-11-89-D
  • GAE75-10-11-89-E
  • GAE75-10-11-89-F
  • GAE75-10-11-89-G
  • GAE75-10-11-89-H
  • GAE75-10-11-89-I
  • GAE75-10-11-89-J
  • GAE75-10-11-89-K
  • GAE75-10-11-89-L
  • GAE75-10-11-89-M
  • GAE75-10-11-89-N
  • GAE75-10-11-89-O
  • GAE75-10-11-89-P
  • GAE75-10-11-89-Q
  • GAE75-10-11-89-R
  • GAE75-10-11-89-S
  • GAE75-10-11-89-T
  • GAE75-10-11-89-U
  • GAE75-10-11-89-V
  • GAE75-10-11-89-W
  • GAE75-10-11-89-X
  • GAE75-10-11-89-Y
  • GAE75-10-11-89-Z

More Products Like This

Customers Are Also Buying

We Deliver!

Late West Coast Shipping Hours
Late West Coast Shipping (5PM PST)
Drop-Ship and Blind-Ship Specialists
Expertly Packed Static-Limited
Same-Day Service
In-House Courier
visa credit card logo mastercard credit card logo discover credit card logo american express credit card logo

Customers we work with

3M logo
Kaiser Permanente logo
Safeway Logo
Georgia-Pacific logo
Coca Cola logo
duke energy logo
BART logo
Pepsi logo
LA DWP logo
US Navy logo
Dean Foods logo
ConAgra Brands logo