1SBL121004M2632
Produktübersicht:
- Extended Product Type: AS16-30-32S-26M
- Product ID: 1SBL121004M2632
- EAN: 3471523074262
- Minimum Order Quantity: 20 piece
- Customs Tariff Number: 85369085
Lassen Sie es uns finden!
oder
rufen Sie an 1 (888) 450-0301
- Beschreibung: AS16-30-32S-26M 230V50/60HZ Contactor
- Rated Impulse Withstand Voltage (Uimp): 6 kV
- Maximum Mechanical Switching Frequency: 3600 cycles per hour
- Rated Control Circuit Voltage (Uc): 50 Hz 230 V 60 Hz 230 V
- Operate Time: Between Coil De-energization and NC Contact Closing 7 ... 22 ms Between Coil De-energization and NO Contact Opening 5 ... 19 ms Between Coil Energization and NC Contact Opening 6 ... 18 ms Between Coil Energization and NO Contact Closing 9 ... 24 ms
- Connecting Capacity Main Circuit: Flexible with Insulated Ferrule 1/2x 0.75 ... 1.5 mm² Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² Rigid 1/2x 0.75 ... 2.5 mm²
- Connecting Capacity Auxiliary Circuit: Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² Flexible with Insulated Ferrule 1/2x 0.75 ... 1.5 mm² Rigid 1/2x 0.75 ... 2.5 mm²
- Connecting Capacity Control Circuit: Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² Flexible with Insulated Ferrule 1/2x 0.75 ... 1.5 mm² Rigid 1/2x 0.75 ... 2.5 mm²
- Wire Stripping Length: Auxiliary Circuit 10 mm Control Circuit 10 mm Main Circuit 10 mm
- Degree of Protection: acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20 acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20
- Terminal Type: Spring Terminals
- Number of Main Contacts NO: 3
- Climatic Withstand: Category B according to IEC 60947-1 Annex Q
- Maximum Operating Altitude Permissible: 3000 m
- Resistance to Vibrations acc. to IEC 60068-2-6: 5 ... 300 Hz 3 g Closed position / 2 g Open position
- Resistance to Shock acc. to IEC 60068-2-27: Closed, Shock Direction: B1 10 g Closed, Shock Direction: C1 20 g Closed, Shock Direction: C2 20 g Open, Shock Direction: B1 5 g Open, Shock Direction: C1 9 g Open, Shock Direction: C2 14 g Shock Direction: A 20 g Shock Direction: B2 15 g
- RoHS Status: Following EU Directive 2011/65/EC
- Ambient Air Temperature: Close to Contactor for Storage -60 ... +80 °C Close to Contactor Fitted with Thermal O/L Relay -25 ... +60 °C Close to Contactor without Thermal O/L Relay -40 ... +70 °C
- General Use Rating UL/CSA: (600 V AC) 15.2 A
- Horsepower Rating UL/CSA: (120 V AC) Single Phase 3/4 Hp (240 V AC) Single Phase 2 Hp (200 ... 208 V AC) Three Phase 3 Hp (220 ... 240 V AC) Three Phase 5 Hp (440 ... 480 V AC) Three Phase 10 Hp (550 ... 600 V AC) Three Phase 10 Hp
- Instructions and Manuals: 1SBC101020M9701
- CB Certificate: CB_CN13475-M1
- CCC Certificate: CCC_2007010309251577
- cUL Certificate: UL_20110325-E312527
- Data Sheet, Technical Information: 1SBC100173C0201
- Declaration of Conformity - CE: 1SBD250014U1000
- GOST Certificate: GOST_POCCCNME77B07822.pdf
- RoHS Information: 1SBD251005E1002
- ETIM 4: EC000066 - Magnet contactor, AC-switching
- ETIM 5: EC000066 - Magnet contactor, AC-switching
- ETIM 6: EC000066 - Power contactor, AC switching
- UNSPSC: 39121529
- Object Classification Code: Q
- Extended Product Type: AS16-30-32S-26M
- Product ID: 1SBL121004M2632
- EAN: 3471523074262
- Minimum Order Quantity: 20 piece
- Customs Tariff Number: 85369085
- EAN: 3471523074262
- Product Net Depth: 110.7 mm
- Product Net Height: 68 mm
- Product Net Weight: 0.260 kg
- Product Net Width: 45 mm
- Package Level 1 Width: 293 mm
- Package Level 1 Length: 128 mm
- Package Level 1 Height: 247 mm
- Package Level 1 Gross Weight: 5.2 kg
- Package Level 1 EAN: 3471523074262
- Package Level 3 Units: 640 piece
- Package Level 1 Units: 20 piece
- Number of Main Contacts NC: 0
- Number of Auxiliary Contacts NO: 3
- Number of Auxiliary Contacts NC: 2
- Standards: IEC 60947-1 / 60947-4-1 and EN 60947-1 / 60947-4-1, UL 508, CSA C22.2 N°14
- Rated Operational Voltage: Auxiliary Circuit 690 V Main Circuit 690 V
- Rated Frequency (f): Auxiliary Circuit 50 / 60 Hz Main Circuit 50 / 60 Hz
- Conventional Free-air Thermal Current (Ith): acc. to IEC 60947-4-1, Open Contactors q = 40 °C 22 A acc. to IEC 60947-5-1, q = 40 °C 10 A
- Rated Operational Current AC-1 (Ie): (690 V) 40 °C 22 A (690 V) 60 °C 17 A (690 V) 70 °C 14 A
- Rated Operational Current AC-3 (Ie): (220 / 230 / 240 V) 60 °C 15.7 A (380 / 400 V) 60 °C 15.5 A (415 V) 60 °C 15.5 A (440 V) 60 °C 13.6 A (500 V) 60 °C 12.5 A (690 V) 60 °C 9 A
- Rated Operational Power AC-3 (Pe): (220 / 230 / 240 V) 4 kW (400 V) 7.5 kW (415 V) 7.5 kW (440 V) 7.5 kW (500 V) 7.5 kW (690 V) 7.5 kW
- Rated Operational Current AC-15 (Ie): (220 / 240 V) 4 A (24 / 127 V) 6 A (400 / 440 V) 3 A (500 V) 2 A (690 V) 2 A
- Rated Short-time Withstand Current (Icw): at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 124 A at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 22 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 55 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 250 A at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 75 A for 0.1 s 140 A for 1 s 100 A
- Maximum Breaking Capacity: cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 155 A cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 90 A
- Maximum Electrical Switching Frequency: AC-1 600 cycles per hour AC-15 1200 cycles per hour AC-2 / AC-4 300 cycles per hour AC-3 1200 cycles per hour DC-13 900 cycles per hour
- Rated Operational Current DC-13 (Ie): (110 V) 0.55 A / 60 W (125 V) 0.55 A / 69 W (220 V) 0.27 A / 60 W (24 V) 6 A / 144 W (250 V) 0.27 A / 68 W (48 V) 2.8 A / 134 W (72 V) 1 A / 72 W
- Rated Insulation Voltage (Ui): acc. to UL/CSA 600 V acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V acc. to IEC 60947-5-1 and VDE 0110 (Gr. C) 690 V
Santa Clara Systems ist spezialisiert auf schwierig auffindbare Artikel. Wählen Sie aus unseren Lagerüberschüssen und sparen Sie 1SBL121004M2632 . Santa Clara Systems führt 36,195 Artikel von ABB.
- With A Non-Removable Front-Mounted 2 N.O. + 2 N.C. Auxiliary Contact Block (Mechanically-Linked Auxiliary Contacts Compliant With Annex L Of Iec 60947-5-1 Including The &Quot;Mechanically Linked&Quot; Symbol On The Contactor Side. N.C. Mirror Contacts Compliant With Annex F Of Iec 60947-4-1) - Control Circuit: Ac Operated With Laminated Magnet Circuit - Accessories: A Wide Range Of Accessories Is Available.
Alternativen
- AS16-30-32S-26M
- AS16 30 32S 26M
- AS163032S26M
Übliche Fehler
- 1SBL121004M263Z
- 1SBL121004M2G32
- 1SBL121004M2G3Z
- 1SBL121004MZ632
- 1SBL121004MZ63Z
- 1SBL121004MZG32
- 1SBL121004MZG3Z
- 1SBL1210O4M2632
- 1SBL1210O4M263Z
- 1SBL1210O4M2G32
- 1SBL1210O4M2G3Z
- 1SBL1210O4MZ632
- 1SBL1210O4MZ63Z
- 1SBL1210O4MZG32
- 1SBL1210O4MZG3Z
- 1SBL121O04M2632
- 1SBL121O04M263Z
- 1SBL121O04M2G32
- 1SBL121O04M2G3Z
- 1SBL121O04MZ632
- 1SBL121O04MZ63Z
- 1SBL121O04MZG32
- 1SBL121O04MZG3Z
- 1SBL121OO4M2632
- 1SBL121OO4M263Z
angehängte Zahlen
- 1SBL121004M2632-A
- 1SBL121004M2632-B
- 1SBL121004M2632-C
- 1SBL121004M2632-D
- 1SBL121004M2632-E
- 1SBL121004M2632-F
- 1SBL121004M2632-G
- 1SBL121004M2632-H
- 1SBL121004M2632-I
- 1SBL121004M2632-J
- 1SBL121004M2632-K
- 1SBL121004M2632-L
- 1SBL121004M2632-M
- 1SBL121004M2632-N
- 1SBL121004M2632-O
- 1SBL121004M2632-P
- 1SBL121004M2632-Q
- 1SBL121004M2632-R
- 1SBL121004M2632-S
- 1SBL121004M2632-T
- 1SBL121004M2632-U
- 1SBL121004M2632-V
- 1SBL121004M2632-W
- 1SBL121004M2632-X
- 1SBL121004M2632-Y
- 1SBL121004M2632-Z
Mehr Produkte wie dieses
-
1SBL121004M2601
ABB
-
1SBL121004M2610
ABB
-
1SBL121004R2601
ABB
-
1SBL121004R2610
ABB
Customers Are Also Buying
-
ZBV G1
Telemecanique
-
3RV1 021-1JA10
Siemens
-
1769-BA (BATTERY)
Allen Bradley
-
440N-G02112
Allen Bradley
Lieferung die auf Ihre Bedürfnisse zugeschnitten sind.

- ✓ Späte Westküstenlieferung (17 Uhr Pazifik)
- ✓ Spezialist für Direktlieferungen and anonyme Lieferungen
- ✓ Fachmännisch verpackt Statisch limitiert
- ✓ Same-Day Service
- ✓ Hausinterner Kurier Domestic and International