1SBL143001R8722

Produktübersicht:

  • Extended Product Type: AL9-30-22 125 V DC
  • Product ID: 1SBL143001R8722
  • EAN: 3471522272874
  • Minimum Order Quantity: 1 piece
  • Customs Tariff Number: 85369085
Lassen Sie es uns finden!
           oder           
rufen Sie an 1 (888) 450-0301
  • Beschreibung: AL9-30-22 125 V DC Contactor
  • Rated Insulation Voltage (Ui): acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V acc. to UL/CSA 600 V
  • Rated Impulse Withstand Voltage (Uimp): 8 kV
  • Mechanical Durability: 10 million
  • Maximum Mechanical Switching Frequency: 3600 cycles per hour
  • Coil Operating Limits: (acc. to IEC 60947-4-1) 0.85 ... 1.1 x Uc (at ? ? 55 °C) °C
  • Rated Control Circuit Voltage (Uc): DC Operation 125 V
  • Coil Consumption: Average Holding Value, from Warm State 3 W Average Pull-in Value, from Cold State 3 W
  • Operate Time: Between Coil Energization and NO Contact Closing 50 ... 100 ms Between Coil De-energization and NO Contact Opening 10 ... 17 ms Between Coil De-energization and NC Contact Closing 16 ... 27 ms Between Coil Energization and NC Contact Opening 20 ... 70 ms
  • Connecting Capacity Main Circuit: Flexible with Cable End 0.75 ... 2.5 mm² Rigid Cable 1 ... 4 mm²
  • Connecting Capacity Auxiliary Circuit: Flexible with Cable End 0.75 ... 2.5 mm² Rigid Cable 1 ... 4 mm²
  • Degree of Protection: acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
  • Connecting terminals (delivered in open position) Main poles: M 3.5 (+,-) pozidriv 2 screw with cable clamp
  • Terminal Type: Screw Terminals
  • Number of Main Contacts NO: 3
  • Climatic Withstand: acc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II
  • Maximum Operating Altitude Permissible: 3000 m
  • RoHS Status: Following EU Directive 2002/95/EC August 18, 2005 and amendment
  • Ambient Air Temperature: Close to Contactor Fitted with Thermal O/L Relay -25 ... +55 °C Close to Contactor for Storage -60 ... +80 °C Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... +55 °C Close to Contactor without Thermal O/L Relay (Uc) -40 ... +70 °C
  • Instructions and Manuals: 1SBC101003M5501
  • CB Certificate: CB_FR_617239A
  • CCC Certificate: CCC_2004010304112227
  • CSA Certificate: CSA_1041746
  • cUL Certificate: UL_20160205-E312527-10-2
  • Data Sheet, Technical Information: 1SBC100122C0202_Ch02
  • Declaration of Conformity - CE: 1SBD250804U1000
  • GL Certificate: GL_26144_05HH
  • GOST Certificate: GOST_POCCFRME77B07175
  • RoHS Information: 1SBD350062R1000
  • UL Listing Card: UL_E312527
  • ETIM 4: EC000066 - Magnet contactor, AC-switching
  • ETIM 5: EC000066 - Magnet contactor, AC-switching
  • ETIM 6: EC000066 - Power contactor, AC switching
  • UNSPSC: 39121529
  • Object Classification Code: Q
  • Extended Product Type: AL9-30-22 125 V DC
  • Product ID: 1SBL143001R8722
  • EAN: 3471522272874
  • Minimum Order Quantity: 1 piece
  • Customs Tariff Number: 85369085
  • EAN: 3471522272874
  • Product Net Depth: 130 mm
  • Product Net Height: 78 mm
  • Product Net Weight: 0.580 kg
  • Product Net Width: 44 mm
  • Package Level 1 Width: 86 mm
  • Package Level 1 Length: 141 mm
  • Package Level 1 Height: 51 mm
  • Package Level 1 Gross Weight: 0.58 kg
  • Package Level 1 EAN: 3471522272874
  • Package Level 2 Units: 28 piece
  • Package Level 3 Units: 336 piece
  • Package Level 1 Units: 1 piece
  • Number of Main Contacts NC: 0
  • Number of Auxiliary Contacts NO: 2
  • Number of Auxiliary Contacts NC: 2
  • Rated Operational Voltage: Main Circuit 690 V Auxiliary Circuit 690 V
  • Rated Frequency (f): Supply Circuit 50 Hz Supply Circuit 60 Hz
  • Conventional Free-air Thermal Current (Ith): acc. to IEC 60947-4-1, Open Contactors q = 40 °C 26 A acc. to IEC 60947-5-1, q = 40 °C 16 A
  • Rated Operational Current AC-1 (Ie): (690 V) 40 °C 25 A (690 V) 55 °C 22 A (690 V) 70 °C 18 A
  • Rated Operational Current AC-3 (Ie): (220 / 230 / 240 V) 55 °C 9 A (380 / 400 V) 55 °C 9 A (415 V) 55 °C 9 A (440 V) 55 °C 9 A (500 V) 55 °C 9 A (690 V) 55 °C 7 A
  • Rated Operational Power AC-3 (Pe): (220 / 230 / 240 V) 2.2 kW (380 / 400 V) 4 kW (415 V) 4 kW (440 V) 4 kW (500 V) 5.5 kW (690 V) 5.5 kW
  • Rated Breaking Capacity AC-3 acc. to IEC 60947-4-1: 8 x Ie AC-3
  • Rated Making Capacity AC-3 acc. to IEC 60947-4-1: 10 x Ie AC-3
  • Rated Operational Current AC-15 (Ie): (220 / 240 V) 4 A (24 / 127 V) 6 A (380 / 440 V) 3 A (500 V) 2 A (690 V) 2 A
  • Short-Circuit Protective Devices: Auxiliary Circuit - gG Type Fuses 10 A gG Type Fuses 25 A
  • Rated Short-time Withstand Current (Icw): at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 100 A at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 26 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 50 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 250 A at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 60 A for 0.1 s 140 A for 1 s 100 A
  • Maximum Breaking Capacity: cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 250 A cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 100 A
  • Maximum Electrical Switching Frequency: AC-1 600 cycles per hour AC-2 / AC-4 300 cycles per hour AC-3 1200 cycles per hour
  • Rated Operational Current DC-13 (Ie): (125 V) 0.55 / 69 A (24 V) 6 / 144 A (250 V) 0.3 / 75 A (48 V) 2.8 / 134 A (72 V) 1 / 72 A
Santa Clara Systems ist spezialisiert auf schwierig auffindbare Artikel. Wählen Sie aus unseren Lagerüberschüssen und sparen Sie 1SBL143001R8722 . Santa Clara Systems führt 35,881 Artikel von ABB.
  • 2Nd Stack With 4 Built-In Auxiliary Contacts
  • Side-Mounted Add-On Auxiliary Contact Blocks (The Built-In Auxiliary Contact Elements Are Mechanically Linked) - Control Circuit: Dc Operated With Solid Core Magnet Circuit. The Polarity On The Coil Terminals (A1+ And A2-) Must Be Respected - Accessories: A Wide Range Of Accessories Is Available. Al... Contactors Are Fitted With Low Consumption Dc Coils And Are Suitable For A Direct Control By Plc Outputs.
  • Al 9 Contactors Are Mainly Used For Controlling 3-Phase Motors And Generally For Controlling Power Circuits Up To 690 V Ac Or 220 V Dc. The Contactors Can Also Be Used For Many Other Applications Such As Isolation
  • Capacitor Switching
  • Lighting. The Al... Series 2-Stack 3-Pole Contactors Are Of The Block Type Design. - Main Poles And Auxiliary Contact Blocks: 1St Stack With 3 Main Poles
  • Alternativen

    • AL9-30-22-87
    • AL9 30 22 87
    • AL9302287

    Übliche Fehler

    • 1SBL143001R872Z
    • 1SBL143001R87Z2
    • 1SBL143001R87ZZ
    • 1SBL143001RB722
    • 1SBL143001RB72Z
    • 1SBL143001RB7Z2
    • 1SBL143001RB7ZZ
    • 1SBL14300IR8722
    • 1SBL14300IR872Z
    • 1SBL14300IR87Z2
    • 1SBL14300IR87ZZ
    • 1SBL14300IRB722
    • 1SBL14300IRB72Z
    • 1SBL14300IRB7Z2
    • 1SBL14300IRB7ZZ
    • 1SBL14300LR8722
    • 1SBL14300LR872Z
    • 1SBL14300LR87Z2
    • 1SBL14300LR87ZZ
    • 1SBL14300LRB722
    • 1SBL14300LRB72Z
    • 1SBL14300LRB7Z2
    • 1SBL14300LRB7ZZ
    • 1SBL1430O1R8722
    • 1SBL1430O1R872Z

    angehängte Zahlen

    • 1SBL143001R8722-A
    • 1SBL143001R8722-B
    • 1SBL143001R8722-C
    • 1SBL143001R8722-D
    • 1SBL143001R8722-E
    • 1SBL143001R8722-F
    • 1SBL143001R8722-G
    • 1SBL143001R8722-H
    • 1SBL143001R8722-I
    • 1SBL143001R8722-J
    • 1SBL143001R8722-K
    • 1SBL143001R8722-L
    • 1SBL143001R8722-M
    • 1SBL143001R8722-N
    • 1SBL143001R8722-O
    • 1SBL143001R8722-P
    • 1SBL143001R8722-Q
    • 1SBL143001R8722-R
    • 1SBL143001R8722-S
    • 1SBL143001R8722-T
    • 1SBL143001R8722-U
    • 1SBL143001R8722-V
    • 1SBL143001R8722-W
    • 1SBL143001R8722-X
    • 1SBL143001R8722-Y
    • 1SBL143001R8722-Z

    Customers Are Also Buying

    Lieferung die auf Ihre Bedürfnisse zugeschnitten sind.

    Late West Coast Shipping Hours
    Späte Westküstenlieferung (17 Uhr Pazifik)
    Spezialist für Direktlieferungen and anonyme Lieferungen
    Fachmännisch verpackt Statisch limitiert
    Same-Day Service
    Hausinterner Kurier Domestic and International
    visa credit card logo mastercard credit card logo discover credit card logo american express credit card logo