• ABB 1SBL241022R8910 UA26-30-10 110-115V 50Hz / 115-127V 60Hz Contactor Product Image
  • Abb 1SBL241022R8910 Barcode

1SBL241022R8910

Produktübersicht:

  • Extended Product Type: UA26-30-10 110-115V 50Hz / 115-127V 60Hz
  • Product ID: 1SBL241022R8910
  • EAN: 3471522069894
  • Minimum Order Quantity: 1 piece
  • Customs Tariff Number: 85369085
Lassen Sie es uns finden!
           oder           
rufen Sie an 1 (888) 450-0301
  • Beschreibung: UA26-30-10 110-115V 50Hz / 115-127V 60Hz Contactor
  • Maximum Mechanical Switching Frequency: 3600 cycles per hour
  • Coil Operating Limits: (acc. to IEC 60947-4-1) 0.85 ... 1.1 x Uc (at ? ? 55 °C) °C
  • Rated Control Circuit Voltage (Uc): 50 Hz 110 115 V 60 Hz 115 127 V
  • Coil Consumption: Pull-in at Max. Rated Control Circuit Voltage 50 Hz 120 V·A Pull-in at Max. Rated Control Circuit Voltage 60 Hz 140 V·A Holding at Max. Rated Control Circuit Voltage 60 Hz 12 V·A Holding at Max. Rated Control Circuit Voltage 60 Hz 3 W Holding at Max. Rated Control Circuit Voltage 50 Hz 12 V·A Holding at Max. Rated Control Circuit Voltage 50 Hz 3 W Average Holding Value 50 / 60 Hz 12 V·A Average Holding Value 50 / 60 Hz 3 W Average Pull-in Value 50 Hz 125 V·A Average Pull-in Value 60 Hz 120 V·A
  • Operate Time: Between Coil Energization and NO Contact Closing 8 ... 21 ms Between Coil De-energization and NO Contact Opening 4 ... 11 ms
  • Connecting Capacity Main Circuit: Flexible with Cable End 0.75 ... 4 mm² Rigid Cable 1.5 ... 6 mm²
  • Connecting Capacity Auxiliary Circuit: Flexible with Cable End 0.75 ... 2.5 mm² Rigid Cable 1 ... 4 mm²
  • Degree of Protection: acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
  • Connecting terminals (delivered in open position) Main poles: M 4 (+,-) pozidriv 2 screws with cable clamp
  • Terminal Type: Screw Terminals
  • Number of Main Contacts NO: 3
  • Climatic Withstand: acc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II
  • Maximum Operating Altitude Permissible: 3000 m
  • RoHS Status: No declaration needed
  • Ambient Air Temperature: Near Contactor for Operation in Free Air (0.85 ... 1.1 Uc) -40 ... +55 °C Near Contactor for Operation in Free Air (Uc) -40 ... +70 °C Close to Contactor for Storage -60 ... +80 °C
  • Instructions and Manuals: FPTC407722P0001
  • CB Certificate: CB_FR2880_60002378
  • CCC Certificate: CCC_2003010304060095
  • CSA Certificate: CSA_1033838_LR056745
  • cUL Certificate: UL_071301E39231
  • Data Sheet, Technical Information: 1SBC101140C0203
  • Declaration of Conformity - CE: 1SBD250805U1000
  • EAC Certificate: EAC_RU C-FR ME77 B01010
  • GOST Certificate: GOST_POCCFRME77B07175
  • RoHS Information: 1SBC101059D0201
  • UL Certificate: UL_071301E39231
  • ETIM 4: EC001079 - Capacitor magnet contactor
  • ETIM 5: EC001079 - Capacitor magnet contactor
  • ETIM 6: EC001079 - Capacitor contactor
  • UNSPSC: 39121529
  • Object Classification Code: Q
  • Extended Product Type: UA26-30-10 110-115V 50Hz / 115-127V 60Hz
  • Product ID: 1SBL241022R8910
  • EAN: 3471522069894
  • Minimum Order Quantity: 1 piece
  • Customs Tariff Number: 85369085
  • EAN: 3471522069894
  • Product Net Depth: 93.6 mm
  • Product Net Height: 90 mm
  • Product Net Weight: 0.600 kg
  • Product Net Width: 54 mm
  • Package Level 1 Width: 101 mm
  • Package Level 1 Length: 115 mm
  • Package Level 1 Height: 61 mm
  • Package Level 1 Gross Weight: 0.6 kg
  • Package Level 1 EAN: 3471522069894
  • Package Level 2 Units: 63 piece
  • Package Level 3 Units: 576 piece
  • Package Level 1 Units: 1 piece
  • Number of Main Contacts NC: 0
  • Number of Auxiliary Contacts NO: 1
  • Number of Auxiliary Contacts NC: 0
  • Rated Operational Voltage: Main Circuit 690 V
  • Rated Frequency (f): Supply Circuit 50 Hz Supply Circuit 60 Hz
  • Conventional Free-air Thermal Current (Ith): acc. to IEC 60947-5-1, q = 40 °C 16 A
  • Rated Operational Current AC-15 (Ie): (220 / 240 V) 4 A (24 / 127 V) 6 A (380 / 440 V) 3 A (500 V) 2 A (690 V) 2 A
  • Short-Circuit Protective Devices: Auxiliary Circuit - gG Type Fuses 10 A gG Type Fuses 1.5 ... 1.8 A
  • Rated Short-time Withstand Current (Icw): at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 210 A at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 45 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 90 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 400 A at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 110 A for 0.1 s 140 A for 1 s 100 A
  • Maximum Breaking Capacity: cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 420 A cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 170 A
  • Rated Operational Current DC-13 (Ie): (125 V) 1.1 / 138 A (24 V) 6 / 144 A (250 V) 0.55 / 138 A (48 V) 2.8 / 134 A (72 V) 2 / 144 A
  • Rated Insulation Voltage (Ui): acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V acc. to UL/CSA 600 V
  • Rated Impulse Withstand Voltage (Uimp): 8 kV
  • Mechanical Durability: 10 million
Santa Clara Systems ist spezialisiert auf schwierig auffindbare Artikel. Wählen Sie aus unseren Lagerüberschüssen und sparen Sie 1SBL241022R8910 . Santa Clara Systems führt 35,877 Artikel von ABB.
  • 1 Built-In Auxiliary Contact - Control Circuit: Ac Operated With Laminated Magnet Circuit - Accessories: A Wide Range Of Accessories Is Available.
  • Ua26 3-Pole Contactors For Capacitor Switching
  • Can Be Used For The Switching Of Capacitor Banks Whose Inrush Current Peaks Are Less Than Or Equal To 100 Times Nominal Rms Current. The Table Below Gives The Permissible Powers According To Operational Voltage And Temperature Close To The Contactor. It Also Specifies The Maximum Peak Current Î Values Accepted By The Contactor. The Capacitors Must Be Discharged (Maximum Residual Voltage At Terminals ? 50 V) Before Being Re-Energized When The Contactors Are Making. In These Conditions
  • Electrical Durability Of Contactors Is Equal To 100 000 Operating Cycles. The Ua.. Series 3-Pole Contactors Are Of The Block Type Design. - Main Poles And Auxiliary Contacts: 3 Main Poles
  • Alternativen

    • UA26-30-10-89
    • UA26 30 10 89
    • UA26301089

    Übliche Fehler

    • 1SBL241022R891O
    • 1SBL241022R89I0
    • 1SBL241022R89IO
    • 1SBL241022R89L0
    • 1SBL241022R89LO
    • 1SBL241022RB910
    • 1SBL241022RB91O
    • 1SBL241022RB9I0
    • 1SBL241022RB9IO
    • 1SBL241022RB9L0
    • 1SBL241022RB9LO
    • 1SBL24102ZR8910
    • 1SBL24102ZR891O
    • 1SBL24102ZR89I0
    • 1SBL24102ZR89IO
    • 1SBL24102ZR89L0
    • 1SBL24102ZR89LO
    • 1SBL24102ZRB910
    • 1SBL24102ZRB91O
    • 1SBL24102ZRB9I0
    • 1SBL24102ZRB9IO
    • 1SBL24102ZRB9L0
    • 1SBL24102ZRB9LO
    • 1SBL2410Z2R8910
    • 1SBL2410Z2R891O

    angehängte Zahlen

    • 1SBL241022R8910-A
    • 1SBL241022R8910-B
    • 1SBL241022R8910-C
    • 1SBL241022R8910-D
    • 1SBL241022R8910-E
    • 1SBL241022R8910-F
    • 1SBL241022R8910-G
    • 1SBL241022R8910-H
    • 1SBL241022R8910-I
    • 1SBL241022R8910-J
    • 1SBL241022R8910-K
    • 1SBL241022R8910-L
    • 1SBL241022R8910-M
    • 1SBL241022R8910-N
    • 1SBL241022R8910-O
    • 1SBL241022R8910-P
    • 1SBL241022R8910-Q
    • 1SBL241022R8910-R
    • 1SBL241022R8910-S
    • 1SBL241022R8910-T
    • 1SBL241022R8910-U
    • 1SBL241022R8910-V
    • 1SBL241022R8910-W
    • 1SBL241022R8910-X
    • 1SBL241022R8910-Y
    • 1SBL241022R8910-Z

    Customers Are Also Buying

    Lieferung die auf Ihre Bedürfnisse zugeschnitten sind.

    Late West Coast Shipping Hours
    Späte Westküstenlieferung (17 Uhr Pazifik)
    Spezialist für Direktlieferungen and anonyme Lieferungen
    Fachmännisch verpackt Statisch limitiert
    Same-Day Service
    Hausinterner Kurier Domestic and International
    visa credit card logo mastercard credit card logo discover credit card logo american express credit card logo