• ABB A50-40-00-42 A50-40-00 230-240V 50Hz / 277V 60Hz Contactor Product Image
  • Abb A50-40-00-42 Barcode

A50-40-00-42

Let Us Find It

Current response time:

By 5AM PT on Tuesday
  • Description: A50-40-00 230-240V 50Hz / 277V 60Hz Contactor
  • Product ID: 1SBL351201R4200
  • Extended Product Type: 1SBL351201R4200
  • Product Net Weight: 1.390 kg
  • Product Net Width: 92 mm
  • Product Net Height: 110 mm
  • Product Net Depth: 119.5 mm
  • Degree of Protection: acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
  • Ambient Air Temperature: Near Contactor for Operation in Free Air (0.85 ... 1.1 Uc) -40 ... +55 C Near Contactor for Operation in Free Air (Uc) -40 ... +70 C Close to Contactor for Storage -60 ... +80 C
  • Standards: Devices complying with international standards IEC 947-1 / 947-4-1, and European standards EN 60 947-1 / 60 947-4-1. Electromagnetic compatibility (EMC) acc. to amendment A11 to IEC 947-1; EN 60 947-1 and amendment 2 to IEC 947-4-1
  • Rated Impulse Withstand Voltage (U<sub>imp</sub>): 8 kV
  • Rated Insulation Voltage (U<sub>i</sub>): acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V acc. to UL/CSA 600 V
  • Terminal Type: Screw Terminals
  • Number of Auxiliary Contacts NO: 0
  • Number of Auxiliary Contacts NC: 0
  • Connecting Capacity Main Circuit: Flexible with Cable End 6 ... 16 mm Rigid Cable 6 ... 25 mm
  • GOST Certificate: GOST_POCCFRME77B07175
  • Maximum Operating Altitude Permissible: 3000 m
  • Rated Control Circuit Voltage (U<sub>c</sub>): 50 Hz 230 240 V 60 Hz 277 V
  • Climatic Withstand: acc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II
  • Maximum Mechanical Switching Frequency: 3600 cycles per hour
  • Connecting Capacity Auxiliary Circuit: Flexible with Cable End 0.75 ... 2.5 mm Rigid Cable 1 ... 4 mm
  • Operate Time: Between Coil Energization and NO Contact Closing 8 ... 27 ms Between Coil De-energization and NO Contact Opening 4 ... 11 ms
  • Number of Main Contacts NO: 4
  • GL Certificate: DNV-GL_TAE00000TX
  • Number of Main Contacts NC: 0
  • Short-Circuit Protective Devices: gG Type Fuses 100 A
  • Maximum Breaking Capacity: cos phi=0.45 (cos phi=0.35 for Ie &gt; 100 A) at 440 V 1300 A cos phi=0.45 (cos phi=0.35 for Ie &gt; 100 A) at 690 V 630 A
  • Coil Consumption: Pull-in at Max. Rated Control Circuit Voltage 50 Hz 180 V&#183;A Pull-in at Max. Rated Control Circuit Voltage 60 Hz 210 V&#183;A Holding at Max. Rated Control Circuit Voltage 60 Hz 18 V&#183;A Holding at Max. Rated Control Circuit Voltage 60 Hz 5.5 W Holding at Max. Rated Control Circuit Voltage 50 Hz 18 V&#183;A Holding at Max. Rated Control Circuit Voltage 50 Hz 5.5 W Average Holding Value 50 / 60 Hz 18 V&#183;A Average Holding Value 50 / 60 Hz 5.5 W Average Pull-in Value 50 Hz 180 V&#183;A Average Pull-in Value 60 Hz 210 V&#183;A
  • Coil Operating Limits: (acc. to IEC 60947-4-1) 0.85 ... 1.1 x Uc (at 55 C) C
  • Connecting terminals (delivered in open position) Main poles: M 6 (+,-) pozidriv 2 screws with 1x (13 x 10 mm) connector
  • EAN: 3471522086426
  • Minimum Order Quantity: 1 piece
  • Customs Tariff Number: 85369085
  • Package Level 1 Width: 142 mm
  • Package Level 1 Length: 190 mm
  • Package Level 1 Height: 136 mm
  • Package Level 1 Gross Weight: 1.39 kg
  • Package Level 1 EAN: 3471522086426
  • Package Level 2 Units: 63 piece
  • Package Level 1 Units: 1 piece
  • Rated Operational Voltage: Main Circuit 1000 V
  • Conventional Free-air Thermal Current (I<sub>th</sub>): acc. to IEC 60947-4-1, Open Contactors q = 40 C 100 A
  • Rated Operational Current AC-1 (I<sub>e</sub>): (690 V) 40 C 100 A (690 V) 55 C 85 A (690 V) 70 C 70 A
  • Rated Operational Current AC-3 (I<sub>e</sub>): (1000 V) 55 C 23 A (220 / 230 / 240 V) 55 C 53 A (380 / 400 V) 55 C 50 A (415 V) 55 C 50 A (440 V) 55 C 45 A (500 V) 55 C 45 A (690 V) 55 C 35 A
  • Rated Breaking Capacity AC-3 acc. to IEC 60947-4-1: 8 x Ie AC-3
  • Rated Making Capacity AC-3 acc. to IEC 60947-4-1: 10 x Ie AC-3
  • Rated Short-time Withstand Current (I<sub>cw</sub>): at 40 C Ambient Temp, in Free Air, from a Cold State 10 s 650 A at 40 C Ambient Temp, in Free Air, from a Cold State 15 min 110 A at 40 C Ambient Temp, in Free Air, from a Cold State 1 min 250 A at 40 C Ambient Temp, in Free Air, from a Cold State 1 s 1000 A at 40 C Ambient Temp, in Free Air, from a Cold State 30 s 370 A
  • Maximum Electrical Switching Frequency: AC-1 600 cycles per hour AC-2 / AC-4 150 cycles per hour AC-3 600 cycles per hour
  • Resistance to Shock acc. to IEC 60068-2-27: Shock Direction: A 20 g Closed, Shock Direction: B1 10 g Open, Shock Direction: B1 5 g Shock Direction: B2 15 g Shock Direction: C1 20 g Shock Direction: C2 20 g
  • RoHS Status: Following EU Directive 2002/95/EC August 18, 2005 and amendment
  • Instructions and Manuals: FPTC407701P0003
  • BV Certificate: BV_2634H07559D0
  • CCC Certificate: CCC_2002010304016447
  • CSA Certificate: CSA_1033838_LR056745
  • cUL Certificate: UL_071301E39231
  • Data Sheet, Technical Information: 1SBC100122C0202_Ch02
  • Declaration of Conformity - CE: 1SBD250802U1000
  • DNV Certificate: DNV-GL_TAE00000TX
  • EAC Certificate: EAC_RU C-FR ME77 B01010
  • LR Certificate: LRS_9830011E4
  • RINA Certificate: RINA_ELE400503CS1
  • RMRS Certificate: RMRS_0507015250
  • RoHS Information: 1SBD350054R1000
  • UL Certificate: UL_071301E39231
  • ETIM 4: EC000066 - Magnet contactor, AC-switching
  • ETIM 5: EC000066 - Magnet contactor, AC-switching
  • ETIM 6: EC000066 - Power contactor, AC switching
  • UNSPSC: 39121529
  • Object Classification Code: Q
Santa Clara Systems specializes in hard-to-find parts. Choose from our overstock inventory and save on A50-40-00-42 . Santa Clara Systems carries 36,673 items from ABB.
  • A50 4-Pole Contactors Are Mainly Used For Controlling Non-Inductive Or Slightly Inductive Loads (I.e. Resistance Furnaces...) And Generally For Controlling Power Circuits Up To 690 V Ac And 440 V Dc. The Contactors Can Also Be Used For Many Other Applications Such Lighting... The A... Series 4-Pole Contactors Are Of The Block Type Design. - Main Poles And Auxiliary Contact Blocks: 4 N.o. Main Poles
  • A50 4-Pole Contactors Are Mainly Used For Controlling Non-Inductive Or Slightly Inductive Loads (I.e. Resistance Furnaces...) And Generally For Controlling Power Circuits Up To 690 V Ac And 440 V Dc. The Contactors Can Also Be Used For Many Other Applications Such Lighting... The A... Series 4-Pole Contactors Are Of The Block Type Design. - Main Poles And Auxiliary Contact Blocks: 4 N.o. Main Poles
  • Front And Side-Mounted Add-On Auxiliary Contact Blocks - Control Circuit: Ac Operated With Laminated Magnet Circuit - Accessories: A Wide Range Of Accessories Is Available.

Alternates

  • 1SBL351201R4200
  • A50 40 00 42
  • A50400042

Common Typos

  • A50-40-00-4Z
  • A50-40-0O-42
  • A50-40-0O-4Z
  • A50-40-O0-42
  • A50-40-O0-4Z
  • A50-40-OO-42
  • A50-40-OO-4Z
  • A50-4O-00-42
  • A50-4O-00-4Z
  • A50-4O-0O-42
  • A50-4O-0O-4Z
  • A50-4O-O0-42
  • A50-4O-O0-4Z
  • A50-4O-OO-42
  • A50-4O-OO-4Z
  • A5O-40-00-42
  • A5O-40-00-4Z
  • A5O-40-0O-42
  • A5O-40-0O-4Z
  • A5O-40-O0-42
  • A5O-40-O0-4Z
  • A5O-40-OO-42
  • A5O-40-OO-4Z
  • A5O-4O-00-42
  • A5O-4O-00-4Z
  • A5O-4O-0O-42

Appended Numbers

  • A50-40-00-42-A
  • A50-40-00-42-B
  • A50-40-00-42-C
  • A50-40-00-42-D
  • A50-40-00-42-E
  • A50-40-00-42-F
  • A50-40-00-42-G
  • A50-40-00-42-H
  • A50-40-00-42-I
  • A50-40-00-42-J
  • A50-40-00-42-K
  • A50-40-00-42-L
  • A50-40-00-42-M
  • A50-40-00-42-N
  • A50-40-00-42-O
  • A50-40-00-42-P
  • A50-40-00-42-Q
  • A50-40-00-42-R
  • A50-40-00-42-S
  • A50-40-00-42-T
  • A50-40-00-42-U
  • A50-40-00-42-V
  • A50-40-00-42-W
  • A50-40-00-42-X
  • A50-40-00-42-Y
  • A50-40-00-42-Z

More Products Like This

Customers Are Also Buying

We Deliver!

Late West Coast Shipping Hours
Late West Coast Shipping (5PM PST)
Drop-Ship and Blind-Ship Specialists
Expertly Packed Static-Limited
Same-Day Service
In-House Courier
visa credit card logo mastercard credit card logo discover credit card logo american express credit card logo

Customers we work with

3M logo
Kaiser Permanente logo
Safeway Logo
Georgia-Pacific logo
Coca Cola logo
duke energy logo
BART logo
Pepsi logo
LA DWP logo
US Navy logo
Dean Foods logo
ConAgra Brands logo