• ABB 1SFL457001R6900 AF110-30-00 48-130V 50/60Hz / DC Contactor Product Image
  • Abb 1SFL457001R6900 Barcode

1SFL457001R6900

Produktübersicht:

  • Extended Product Type: AF110-30-00 48-130V 50/60Hz / DC
  • Product ID: 1SFL457001R6900
  • EAN: 7320500239667
  • Minimum Order Quantity: 1 piece
  • Customs Tariff Number: 85364900
Lassen Sie es uns finden!
           oder           
rufen Sie an 1 (888) 450-0301
  • Beschreibung: AF110-30-00 48-130V 50/60Hz / DC Contactor
  • Maximum Mechanical Switching Frequency: 300 cycles per hour
  • Coil Operating Limits: (acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at ? ? 70 °C) °C
  • Rated Control Circuit Voltage (Uc): 60 Hz 48 130 V 50 Hz 48 130 V DC Operation 48 130 V
  • Coil Consumption: Pull-in at Max. Rated Control Circuit Voltage 60 Hz 350 V·A Holding at Max. Rated Control Circuit Voltage DC 2 W Holding at Max. Rated Control Circuit Voltage 50 Hz 7 V·A Pull-in at Max. Rated Control Circuit Voltage DC 400 W Pull-in at Max. Rated Control Circuit Voltage 50 Hz 350 V·A Holding at Max. Rated Control Circuit Voltage 60 Hz 7 V·A
  • Operate Time: Between Coil Energization and NO Contact Closing 3080 ms Between Coil De-energization and NO Contact Opening 55125 ms Between Coil De-energization and NC Contact Closing 60130 ms Between Coil Energization and NC Contact Opening 2777 ms
  • Connecting Capacity Main Circuit: Flexible with Cable End 1x1070 mm² Bar 30 mm² Rigid 2x665 mm²
  • Connecting Capacity Auxiliary Circuit: Solid 2x14 mm² Flexible with Insulated Ferrule 2x0.752.5 mm² Stranded 2x14 mm² Flexible 2x0.752.5 mm² Flexible with Ferrule 2x0.752.5 mm²
  • Degree of Protection: acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
  • Connecting terminals (delivered in open position) Main poles: M8 hexagon socket screw with single connector
  • Terminal Type: Cable Clamp
  • Number of Main Contacts NO: 3
  • Maximum Operating Altitude Permissible: 3000 m
  • Resistance to Shock acc. to IEC 60068-2-27: Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: A 20 g Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: C2 20 g Half-sine Pulse for 11 ms, No Change in Contact Position, Closed, Shock Direction: B1 15 g Half-sine Pulse for 11 ms, No Change in Contact Position, Closed, Shock Direction: A 20 g Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: C1 20 g Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: B2 15 g Half-sine Pulse for 11 ms, No Change in Contact Position, Closed, Shock Direction: C2 20 g Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: B1 5 g Half-sine Pulse for 11 ms, No Change in Contact Position, Closed, Shock Direction: C1 20 g
  • RoHS Status: Following EU Directive 2002/95/EC August 18, 2005 and amendment
  • Ambient Air Temperature: Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25+50 °C Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40+70 °C Close to Contactor for Storage -60+80 °C
  • General Use Rating UL/CSA: (600 V AC) 140 A
  • Horsepower Rating UL/CSA: (208 V AC) Three Phase 30 Hp (440 ... 480 V AC) Three Phase 75 Hp (550 ... 600 V AC) Three Phase 100 Hp (220 ... 240 V AC) Three Phase 40 Hp (200 V AC) Three Phase 30 Hp
  • Maximum Operating Voltage UL/CSA: Main Circuit 600 V
  • Instructions and Manuals: 5309660-60
  • BV Certificate: 13409/C0 BV
  • CB Certificate: SE-73663
  • CCC Certificate: CQC_2002010304007860
  • Data Sheet, Technical Information: 1SBC100122C0202
  • Declaration of Conformity - CE: 1SFA1-66
  • GL Certificate: GL_20260-04HH
  • LOVAG Certificate: SE-0145185
  • LR Certificate: LR_04-00015-E1
  • RINA Certificate: ELE060313XG/002
  • RMRS Certificate: RMRS_12-03683-315
  • RoHS Information: 1SFC101055D0202
  • E-nummer: 3228278
  • ETIM 4: EC000066 - Magnet contactor, AC-switching
  • ETIM 5: EC000066 - Magnet contactor, AC-switching
  • UNSPSC: 39121529
  • Object Classification Code: Q
  • Extended Product Type: AF110-30-00 48-130V 50/60Hz / DC
  • Product ID: 1SFL457001R6900
  • EAN: 7320500239667
  • Minimum Order Quantity: 1 piece
  • Customs Tariff Number: 85364900
  • EAN: 7320500239667
  • Product Net Depth: 123.5 mm
  • Product Net Height: 148.0 mm
  • Product Net Weight: 2.100 kg
  • Product Net Width: 90.0 mm
  • Package Level 1 Width: 140 mm
  • Package Level 1 Length: 140 mm
  • Package Level 1 Height: 170 mm
  • Package Level 1 Gross Weight: 2.1 kg
  • Package Level 1 EAN: 7320500239667
  • Package Level 1 Units: 1 piece
  • Number of Main Contacts NC: 0
  • Number of Auxiliary Contacts NO: 0
  • Number of Auxiliary Contacts NC: 0
  • Rated Operational Voltage: Main Circuit 1000 V
  • Rated Frequency (f): Main Circuit 50/60 Hz
  • Conventional Free-air Thermal Current (Ith): acc. to IEC 60947-4-1, Open Contactors q = 40 °C 160 A
  • Rated Operational Current AC-1 (Ie): (690 V) 55 °C 145 A (690 V) 40 °C 160 A (690 V) 70 °C 130 A
  • Rated Operational Current AC-3 (Ie): (1000 V) 55 °C 30 A (415 V) 55 °C 110 A (690 V) 55 °C 82 A (220 / 230 / 240 V) 55 °C 110 A (440 V) 55 °C 100 A (380 / 400 V) 55 °C 110 A (500 V) 55 °C 100 A
  • Rated Operational Power AC-3 (Pe): (500 V) 59 kW (1000 V) 40 kW (690 V) 75 kW (220 / 230 / 240 V) 30 kW (380 / 400 V) 55 kW (440 V) 59 kW (415 V) 59 kW
  • Rated Breaking Capacity AC-3 acc. to IEC 60947-4-1: 8 x Ie AC-3
  • Rated Making Capacity AC-3 acc. to IEC 60947-4-1: 10 x Ie AC-3
  • Short-Circuit Protective Devices: gG Type Fuses 160 A
  • Maximum Breaking Capacity: cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1160 A cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 800 A
  • Maximum Electrical Switching Frequency: AC-3 300 cycles per hour AC-1 300 cycles per hour AC-2 / AC-4 150 cycles per hour
  • Rated Operational Current DC-1 (Ie): (110 V) 2 Poles in Series, 40 °C 160 A (220 V) 3 Poles in Series, 40 °C 160 A
  • Rated Operational Current DC-3 (Ie): (110 V) 2 Poles in Series, 40 °C 160 A (220 V) 3 Poles in Series, 40 °C 160 A
  • Rated Operational Current DC-5 (Ie): (110 V) 2 Poles in Series, 40 °C 160 A (220 V) 3 Poles in Series, 40 °C 160 A
  • Rated Insulation Voltage (Ui): acc. to UL/CSA 600 V acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V
  • Rated Impulse Withstand Voltage (Uimp): Main Circuit 8 kV
  • Mechanical Durability: 10 million
Santa Clara Systems ist spezialisiert auf schwierig auffindbare Artikel. Wählen Sie aus unseren Lagerüberschüssen und sparen Sie 1SFL457001R6900 . Santa Clara Systems führt 35,866 Artikel von ABB.
  • Ac/Dc
  • A 3-Phase Contactor Suitable For Various Applications Such As Motor Starting
  • Isolation
  • By-Pass And Distribution Application Up To Max 1000 V. Operated With Wide Control Voltage Range 48-130 V
  • Alternativen

    • AF110-30-00-6900
    • AF110 30 00 6900
    • AF11030006900

    Übliche Fehler

    • 1SFL457001R690O
    • 1SFL457001R69O0
    • 1SFL457001R69OO
    • 1SFL457001RG900
    • 1SFL457001RG90O
    • 1SFL457001RG9O0
    • 1SFL457001RG9OO
    • 1SFL45700IR6900
    • 1SFL45700IR690O
    • 1SFL45700IR69O0
    • 1SFL45700IR69OO
    • 1SFL45700IRG900
    • 1SFL45700IRG90O
    • 1SFL45700IRG9O0
    • 1SFL45700IRG9OO
    • 1SFL45700LR6900
    • 1SFL45700LR690O
    • 1SFL45700LR69O0
    • 1SFL45700LR69OO
    • 1SFL45700LRG900
    • 1SFL45700LRG90O
    • 1SFL45700LRG9O0
    • 1SFL45700LRG9OO
    • 1SFL4570O1R6900
    • 1SFL4570O1R690O

    angehängte Zahlen

    • 1SFL457001R6900-A
    • 1SFL457001R6900-B
    • 1SFL457001R6900-C
    • 1SFL457001R6900-D
    • 1SFL457001R6900-E
    • 1SFL457001R6900-F
    • 1SFL457001R6900-G
    • 1SFL457001R6900-H
    • 1SFL457001R6900-I
    • 1SFL457001R6900-J
    • 1SFL457001R6900-K
    • 1SFL457001R6900-L
    • 1SFL457001R6900-M
    • 1SFL457001R6900-N
    • 1SFL457001R6900-O
    • 1SFL457001R6900-P
    • 1SFL457001R6900-Q
    • 1SFL457001R6900-R
    • 1SFL457001R6900-S
    • 1SFL457001R6900-T
    • 1SFL457001R6900-U
    • 1SFL457001R6900-V
    • 1SFL457001R6900-W
    • 1SFL457001R6900-X
    • 1SFL457001R6900-Y
    • 1SFL457001R6900-Z

    Customers Are Also Buying

    Lieferung die auf Ihre Bedürfnisse zugeschnitten sind.

    Late West Coast Shipping Hours
    Späte Westküstenlieferung (17 Uhr Pazifik)
    Spezialist für Direktlieferungen and anonyme Lieferungen
    Fachmännisch verpackt Statisch limitiert
    Same-Day Service
    Hausinterner Kurier Domestic and International
    visa credit card logo mastercard credit card logo discover credit card logo american express credit card logo