• ABB AF300-30-22-70 AF300-30-22 100-250V 50/60Hz / 100-250V DC Contactor Product Image
  • Abb AF300-30-22-70 Barcode

AF300-30-22-70

Let Us Find It

Current response time:

By 5AM PT on Tuesday
  • Description: AF300-30-22 100-250V 50/60Hz / 100-250V DC Contactor
  • Product ID: 1SFL557001R7022
  • Extended Product Type: 1SFL557001R7022
  • Product Net Weight: 5.800 kg
  • Product Net Width: 140.0 mm
  • Product Net Height: 227.0 mm
  • Product Net Depth: 180.5 mm
  • Degree of Protection: acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
  • Ambient Air Temperature: Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25+50 C Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40+70 C Close to Contactor for Storage -40+70 C
  • Rated Impulse Withstand Voltage (U<sub>imp</sub>): Main Circuit 8 kV
  • Rated Insulation Voltage (U<sub>i</sub>): acc. to UL/CSA 600 V acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V
  • Terminal Type: Main Circuit: Bars
  • Rated Frequency (f): Main Circuit 50/60 Hz
  • Number of Auxiliary Contacts NO: 2
  • Number of Auxiliary Contacts NC: 2
  • Mechanical Durability: 5 million
  • Connecting Capacity Main Circuit: Rigid Al-Cable 120240 mm Bar 32 mm Rigid Cu-Cable 16240 mm
  • Maximum Operating Voltage UL/CSA: Main Circuit 600 V
  • Maximum Operating Altitude Permissible: 3000 m
  • Rated Control Circuit Voltage (U<sub>c</sub>): 60 Hz 100 250 V 50 Hz 100 250 V DC Operation 100 250 V
  • Maximum Mechanical Switching Frequency: 300 cycles per hour
  • Connecting Capacity Auxiliary Circuit: Solid 1x14 mm Flexible with Insulated Ferrule 2x0.752.5 mm Stranded 2x14 mm Flexible 2x0.752.5 mm Flexible with Ferrule 2x0.752.5 mm
  • Operate Time: Between Coil Energization and NO Contact Closing 50 ... 90 ms Between Coil De-energization and NO Contact Opening 43 ... 53 ms Between Coil De-energization and NC Contact Closing 40 .... 50 ms Between Coil Energization and NC Contact Opening 45 ... 85 ms
  • Country of Origin: Sweden (SE)
  • Number of Main Contacts NO: 3
  • GL Certificate: GL_20262-04HH
  • Number of Main Contacts NC: 0
  • Short-Circuit Protective Devices: gG Type Fuses 500 A
  • Maximum Breaking Capacity: cos phi=0.45 (cos phi=0.35 for Ie &gt; 100 A) at 440 V 3000 A cos phi=0.45 (cos phi=0.35 for Ie &gt; 100 A) at 690 V 2500 A
  • Coil Consumption: Pull-in at Max. Rated Control Circuit Voltage 60 Hz 470 V&#183;A Holding at Max. Rated Control Circuit Voltage DC 2 W Holding at Max. Rated Control Circuit Voltage 50 Hz 10 V&#183;A Pull-in at Max. Rated Control Circuit Voltage DC 520 W Pull-in at Max. Rated Control Circuit Voltage 50 Hz 470 V&#183;A Holding at Max. Rated Control Circuit Voltage 60 Hz 10 V&#183;A
  • Coil Operating Limits: (acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at 70 C) C
  • Horsepower Rating UL/CSA: (208 V AC) Three Phase 100 Hp (440 ... 480 V AC) Three Phase 250 Hp (550 ... 600 V AC) Three Phase 300 Hp (220 ... 240 V AC) Three Phase 100 Hp (200 V AC) Three Phase 100 Hp
  • General Use Rating UL/CSA: (600 V AC) 400 A
  • Lead Time: 999 day(s)
  • EAN: 7320500222843
  • Criticality: No
  • Replacement Part ID: <a href='javascript:constructLinkToDetailPage("TEMP.FIDRI68604168", "", "ROOT","");'>68604168</a>
  • Minimum Order Quantity: 1 piece
  • Customs Tariff Number: 85364900
  • Package Level 1 Width: 200 mm
  • Package Level 1 Length: 220 mm
  • Package Level 1 Height: 280 mm
  • Package Level 1 Gross Weight: 5.8 kg
  • Package Level 1 EAN: 7320500222843
  • Package Level 1 Units: 1 piece
  • Rated Operational Voltage: Main Circuit 690 V
  • Conventional Free-air Thermal Current (I<sub>th</sub>): acc. to IEC 60947-4-1, Open Contactors q = 40 C 500 A
  • Rated Operational Current AC-1 (I<sub>e</sub>): (690 V) 55 C 400 A (690 V) 40 C 500 A (690 V) 70 C 325 A
  • Rated Operational Current AC-3 (I<sub>e</sub>): (220 / 230 / 240 V) 55 C 305 A (690 V) 55 C 280 A (415 V) 55 C 300 A (440 V) 55 C 280 A (380 / 400 V) 55 C 305 A (500 V) 55 C 280 A
  • Rated Operational Power AC-3 (P<sub>e</sub>): (500 V) 200 kW (220 / 230 / 240 V) 90 kW (690 V) 250 kW (380 / 400 V) 160 kW (440 V) 160 kW (415 V) 160 kW
  • Rated Breaking Capacity AC-3 acc. to IEC 60947-4-1: 8 x Ie AC-3
  • Rated Making Capacity AC-3 acc. to IEC 60947-4-1: 10 x Ie AC-3
  • Rated Short-time Withstand Current (I<sub>cw</sub>): at 40 C Ambient Temp, in Free Air, from a Cold State 15 min 500 A at 40 C Ambient Temp, in Free Air, from a Cold State 30 s 1500 A at 40 C Ambient Temp, in Free Air, from a Cold State 10 s 2400 A at 40 C Ambient Temp, in Free Air, from a Cold State 1 s 3500 A at 40 C Ambient Temp, in Free Air, from a Cold State 1 min 1100 A
  • Maximum Electrical Switching Frequency: AC-3 300 cycles per hour AC-1 300 cycles per hour AC-2 / AC-4 150 cycles per hour
  • Rated Operational Current DC-1 (I<sub>e</sub>): (110 V) 2 Poles in Series, 40 C 450 A (220 V) 3 Poles in Series, 40 C 450 A
  • Rated Operational Current DC-3 (I<sub>e</sub>): (110 V) 2 Poles in Series, 40 C 450 A (220 V) 3 Poles in Series, 40 C 450 A
  • Rated Operational Current DC-5 (I<sub>e</sub>): (110 V) 2 Poles in Series, 40 C 450 A (220 V) 3 Poles in Series, 40 C 450 A
  • Resistance to Shock acc. to IEC 60068-2-27: Shock Direction: A 5 g Shock Direction: C2 5 g Shock Direction: B2 5 g Shock Direction: C1 5 g Shock Direction: B1 5 g
  • RoHS Status: Following EU Directive 2002/95/EC August 18, 2005 and amendment
  • Instructions and Manuals: 1SFC380003-89
  • BV Certificate: 13409/C0 BV
  • CB Certificate: SE-69480
  • CCC Certificate: CQC_2007010304256681
  • Data Sheet, Technical Information: 1SBC100122C0202
  • Declaration of Conformity - CE: 1SFA1-62
  • LOVAG Certificate: SE-0115200
  • LR Certificate: LR_04-00015-E1
  • RINA Certificate: ELE060313XG/002
  • RMRS Certificate: RMRS_12-03683-315
  • RoHS Information: 1SFC101055D0202
  • ETIM 4: EC000066 - Magnet contactor, AC-switching
  • ETIM 5: EC000066 - Magnet contactor, AC-switching
  • UNSPSC: 39121529
  • Object Classification Code: Q
Santa Clara Systems specializes in hard-to-find parts. Choose from our overstock inventory and save on AF300-30-22-70 . Santa Clara Systems carries 36,673 items from ABB.
  • Ac/dc
  • A 3-Phase Contactor Suitable For Various Applications Such As Motor Starting
  • Isolation
  • By-Pass And Distribution Application Up To Max 690 V. Operated With Wide Control Voltage Range 100-250 V

Alternates

  • 1SFL557001R7022
  • AF300 30 22 70
  • AF300302270

Common Typos

  • AF300-30-22-7O
  • AF300-30-2Z-70
  • AF300-30-2Z-7O
  • AF300-30-Z2-70
  • AF300-30-Z2-7O
  • AF300-30-ZZ-70
  • AF300-30-ZZ-7O
  • AF300-3O-22-70
  • AF300-3O-22-7O
  • AF300-3O-2Z-70
  • AF300-3O-2Z-7O
  • AF300-3O-Z2-70
  • AF300-3O-Z2-7O
  • AF300-3O-ZZ-70
  • AF300-3O-ZZ-7O
  • AF30O-30-22-70
  • AF30O-30-22-7O
  • AF30O-30-2Z-70
  • AF30O-30-2Z-7O
  • AF30O-30-Z2-70
  • AF30O-30-Z2-7O
  • AF30O-30-ZZ-70
  • AF30O-30-ZZ-7O
  • AF30O-3O-22-70
  • AF30O-3O-22-7O
  • AF30O-3O-2Z-70

Appended Numbers

  • AF300-30-22-70-A
  • AF300-30-22-70-B
  • AF300-30-22-70-C
  • AF300-30-22-70-D
  • AF300-30-22-70-E
  • AF300-30-22-70-F
  • AF300-30-22-70-G
  • AF300-30-22-70-H
  • AF300-30-22-70-I
  • AF300-30-22-70-J
  • AF300-30-22-70-K
  • AF300-30-22-70-L
  • AF300-30-22-70-M
  • AF300-30-22-70-N
  • AF300-30-22-70-O
  • AF300-30-22-70-P
  • AF300-30-22-70-Q
  • AF300-30-22-70-R
  • AF300-30-22-70-S
  • AF300-30-22-70-T
  • AF300-30-22-70-U
  • AF300-30-22-70-V
  • AF300-30-22-70-W
  • AF300-30-22-70-X
  • AF300-30-22-70-Y
  • AF300-30-22-70-Z

More Products Like This

Customers Are Also Buying

We Deliver!

Late West Coast Shipping Hours
Late West Coast Shipping (5PM PST)
Drop-Ship and Blind-Ship Specialists
Expertly Packed Static-Limited
Same-Day Service
In-House Courier
visa credit card logo mastercard credit card logo discover credit card logo american express credit card logo

Customers we work with

3M logo
Kaiser Permanente logo
Safeway Logo
Georgia-Pacific logo
Coca Cola logo
duke energy logo
BART logo
Pepsi logo
LA DWP logo
US Navy logo
Dean Foods logo
ConAgra Brands logo