2CDS251001R0204
Produktübersicht:
- Extended Product Type: S201-C20
- Product ID: 2CDS251001R0204
- EAN: 4016779464505
- Minimum Order Quantity: 1 piece
- Customs Tariff Number: 85362010
Lassen Sie es uns finden!
oder
rufen Sie an 1 (888) 450-0301
- Beschreibung: Miniature Circuit Breaker - S200 - 1P - C - 20 A
- Rated Service Short-Circuit Breaking Capacity (Ics): 7.5 kA
- Energy Limiting Class: 3
- Overvoltage Category: III
- Pollution Degree: 3
- Rated Impulse Withstand Voltage (Uimp): 4 kV (6.2 kV @ sea level) (5.0 kV @ 2000 m)
- Dielectric Test Voltage: 50 / 60 Hz, 1 min: 2 kV
- Housing Material: Insulation Group II, RAL 7035
- Actuator Type: Insulation group II, black, sealable
- Contact Position Indication: Red ON / Green OFF
- Degree of Protection: IP20
- Remarks: IP40 in enclosure with cover
- Electrical Endurance: 20000 AC cycle
- Mechanical Endurance: 20000 cycle
- Terminal Type: Screw Terminals
- Screw Terminal Type: Failsafe Bi-directional Cylinder-lift Terminal
- Connecting Capacity: Busbar 10 / 10 mm² Flexible with Ferrule 0.75 ... 25 mm² Flexible 0.75 ... 25 mm² Rigid 0.75 ... 35 mm² Stranded 0.75 ... 35 mm²
- Tightening Torque: 2.8 N·m
- Recommended Screw Driver: Pozidriv 2
- Mounting on DIN Rail: TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
- Mounting Position: Any
- Standards: IEC/EN 60898-1 IEC/EN 60947-2 UL 1077
- Connecting Capacity UL/CSA: Busbar 18-8 AWG Conductor 18-4 AWG
- Tightening Torque UL/CSA: 25 in·lb
- Interrupting Rating acc. to UL1077: 6 kA (DC) 10 kA
- Maximum Operating Voltage UL/CSA: 277 V AC
- Instructions and Manuals: 2CSC400002D0208
- Data Sheet, Technical Information: 2CSC400002D0208
- Declaration of Conformity - CE: 2CDK403001D0604
- RoHS Information: 2CDK400003K0201
- E-nummer: 2100522
- ETIM 4: EC000042 - Miniature circuit breaker (MCB)
- ETIM 5: EC000042 - Miniature circuit breaker (MCB)
- ETIM 6: EC000042 - Miniature circuit breaker (MCB)
- eClass: 7.0 27141901
- UNSPSC: 39121614
- Object Classification Code: F
- Extended Product Type: S201-C20
- Product ID: 2CDS251001R0204
- EAN: 4016779464505
- Minimum Order Quantity: 1 piece
- Customs Tariff Number: 85362010
- EAN: 4016779464505
- Product Net Depth: 69 mm
- Product Net Height: 88 mm
- Product Net Weight: 0.125 kg
- Product Net Width: 17.5 mm
- Package Level 1 Width: 92 mm
- Package Level 1 Length: 183 mm
- Package Level 1 Height: 80 mm
- Package Level 1 Gross Weight: 1.295 kg
- Package Level 1 EAN: 4016779606905
- Package Level 2 Units: 120 piece
- Package Level 2 Width: 275 mm
- Package Level 2 Length: 395 mm
- Package Level 2 Height: 210 mm
- Package Level 2 Gross Weight: 14.8 kg
- Package Level 2 EAN: 4016779970754
- Package Level 1 Units: 10 piece
- Ambient Air Temperature: Operation -25 ... +55 °C Storage -40 ... +70 °C
- Resistance to Shock acc. to IEC 60068-2-27: 25g / 2 shocks / 13 ms
- Resistance to Vibrations acc. to IEC 60068-2-6: 5g, 20 cycles at 5 ... 150 ... 5 Hz with load 0.8 In
- Environmental Conditions: 28 cycles with 55 °C / 90-96 % and 25 °C / 95-100 %
- RoHS Status: Following EU Directive 2002/95/EC August 18, 2005 and amendment
- Number of Poles: 1
- Tripping Characteristic: C
- Rated Current (In): 20 A
- Rated Operational Voltage: acc. to IEC 60898-1 230 / 400 V AC acc. to IEC 60947-2 230 V AC
- Power Loss: 2.5 W at Rated Operating Conditions per Pole 2.5 W
- Rated Insulation Voltage (Ui): acc. to IEC/EN 60664-1 440 V
- Operational Voltage: Maximum (Incl. Tolerance) 253 V AC Maximum (Incl. Tolerance) 72 V DC Minimum 12 V AC / 12 V DC
- Rated Frequency (f): 50 Hz 60 Hz
- Rated Short-Circuit Capacity (Icn): (AC) 6 kA 6 kA (DC) kA
- Rated Ultimate Short-Circuit Breaking Capacity (Icu): 10 kA 10 kA (DC) kA
Santa Clara Systems ist spezialisiert auf schwierig auffindbare Artikel. Wählen Sie aus unseren Lagerüberschüssen und sparen Sie 2CDS251001R0204 . Santa Clara Systems führt 36,195 Artikel von ABB.
- 3P
- 3P+N
- 4P)
- Breaking Capacities (Up To 6 Ka At 230/400 V Ac) And Rated Currents (Up To 63A). All Mcbs Of The Product Range S200 Comply With Iec/En 60898-1
- Iec/En 60947-2
- Ul1077 And Csa 22.2 No. 235
- Allowing The Use For Residential
- Commercial And Industrial Applications. Bottom-Fitting Auxiliary Contact Can Be Mounted On S200 To Save 50% Space.
Alternativen
- S201-C20
- S201 C20
- S201C20
Übliche Fehler
- 2CDS251001R02O4
- 2CDS251001R0Z04
- 2CDS251001R0ZO4
- 2CDS251001RO204
- 2CDS251001RO2O4
- 2CDS251001ROZ04
- 2CDS251001ROZO4
- 2CDS25100IR0204
- 2CDS25100IR02O4
- 2CDS25100IR0Z04
- 2CDS25100IR0ZO4
- 2CDS25100IRO204
- 2CDS25100IRO2O4
- 2CDS25100IROZ04
- 2CDS25100IROZO4
- 2CDS25100LR0204
- 2CDS25100LR02O4
- 2CDS25100LR0Z04
- 2CDS25100LR0ZO4
- 2CDS25100LRO204
- 2CDS25100LRO2O4
- 2CDS25100LROZ04
- 2CDS25100LROZO4
- 2CDS2510O1R0204
- 2CDS2510O1R02O4
angehängte Zahlen
- 2CDS251001R0204-A
- 2CDS251001R0204-B
- 2CDS251001R0204-C
- 2CDS251001R0204-D
- 2CDS251001R0204-E
- 2CDS251001R0204-F
- 2CDS251001R0204-G
- 2CDS251001R0204-H
- 2CDS251001R0204-I
- 2CDS251001R0204-J
- 2CDS251001R0204-K
- 2CDS251001R0204-L
- 2CDS251001R0204-M
- 2CDS251001R0204-N
- 2CDS251001R0204-O
- 2CDS251001R0204-P
- 2CDS251001R0204-Q
- 2CDS251001R0204-R
- 2CDS251001R0204-S
- 2CDS251001R0204-T
- 2CDS251001R0204-U
- 2CDS251001R0204-V
- 2CDS251001R0204-W
- 2CDS251001R0204-X
- 2CDS251001R0204-Y
- 2CDS251001R0204-Z
Mehr Produkte wie dieses
-
2CDS251001R0205
ABB
-
2CDS251001R0217
ABB
-
2CDS251001R0218
ABB
-
2CDS251001R0254
ABB
Customers Are Also Buying
-
440R-B23020
Allen Bradley
-
440P-CRPS11B
Allen Bradley
-
Q6BAT (BATTERY)
Mitsubishi
-
440N-Z21SS2BN9
Allen Bradley
Lieferung die auf Ihre Bedürfnisse zugeschnitten sind.

- ✓ Späte Westküstenlieferung (17 Uhr Pazifik)
- ✓ Spezialist für Direktlieferungen and anonyme Lieferungen
- ✓ Fachmännisch verpackt Statisch limitiert
- ✓ Same-Day Service
- ✓ Hausinterner Kurier Domestic and International