• ABB CM-PAS.41P CM-PAS.41P Three-phase monitoring relay 2c/o, 0,0.1-30s, L1-L2-L3=3x300-500VAC Product Image
  • Abb CM-PAS.41P Barcode

CM-PAS.41P

Let Us Find It

Current response time:

19 Minutes 53 Seconds
  • Description: CM-PAS.41P Three-phase monitoring relay 2c/o, 0,0.1-30s, L1-L2-L3=3x300-500VAC
  • Product ID: 1SVR740774R3300
  • Extended Product Type: 1SVR740774R3300
  • Product Net Weight: 0.123 kg
  • Product Net Width: 22.5 mm
  • Product Net Height: 85.6 mm
  • Product Net Depth: 103.7 mm
  • Degree of Protection: Housing IP50 Terminals IP20
  • Ambient Air Temperature: Operation -25 ... +60 C Storage -40 ... +85 C
  • Standards: EN 50178 IEC/EN 61000-6-2 IEC/EN 61000-6-3 UL 508 CAN/CSA C22.2 No.14
  • Rated Impulse Withstand Voltage (U<sub>imp</sub>): Input Circuit 6 kV Output Circuit 4 kV
  • Rated Insulation Voltage (U<sub>i</sub>): Input Circuit / Output Circuit 600 V Output Circuit 1 / Output Circuit 2 300 V
  • Terminal Type: Screwless Terminals
  • Function: Phase failure detection Phase sequence monitoring Phase unbalance detection
  • Rated Frequency (f): Supply Circuit 50/60 Hz
  • Mounting on DIN Rail: TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
  • eClass: 7.0 27371803
  • Mounting Position: Any
  • Mechanical Durability: 30000000 cycle
  • Connecting Capacity: Flexible with Ferrule 2x 0.5 ... 1.5 mm Flexible with Insulated Ferrule 2x 0.5 ... 1.5 mm Flexible 2x 0.5 ... 1.5 mm Rigid 2x 0.5 ... 1.5 mm
  • Maximum Operating Voltage UL/CSA: Output Circuit 300 V AC
  • Overvoltage Category: III
  • Connecting Capacity UL/CSA: Flexible 2x 18-16 AWG Rigid 2x 20-16 AWG
  • Wire Stripping Length: 8 mm
  • GL Certificate: GL_37695-12HH
  • Short-Circuit Protective Devices: Output Circuit NC - F Type Fuses 6 A Output Circuit NO - F Type Fuses 10 A
  • Rated Control Supply Voltage (U<sub>s</sub>): (L-L) 300 ... 500 V AC
  • Output: 2 c/o (SPDT) contacts
  • Electrical Durability: AC-12 100000 cycle
  • EAN: 4016779851985
  • Minimum Order Quantity: 1 piece
  • Customs Tariff Number: 85364900
  • Package Level 1 Width: 97 mm
  • Package Level 1 Height: 109 mm
  • Package Level 1 Length: 30 mm
  • Package Level 1 Gross Weight: 0.148 kg
  • Package Level 1 Units: 1 piece
  • Measuring Range: (L-L) 300 ... 500 V AC
  • Time Range: 200 ms start-up delay 0 s or 0.1-30 s tripping delay (ON)
  • Rated Operational Current AC-12 (I<sub>e</sub>): (230 V) 4 A
  • Rated Operational Current AC-15 (I<sub>e</sub>): (230 V) 3 A
  • Rated Operational Current DC-12 (I<sub>e</sub>): (24 V) 4 A
  • Rated Operational Current DC-13 (I<sub>e</sub>): (24 V) 2 A
  • Minimum Switching Capacity: 24 V 10 mA
  • Pollution Degree: 3
  • RoHS Status: Following EU Directive 2011/65/EC
  • Contact Rating UL/CSA: B300
  • Instructions and Manuals: 1SVC730510M0000
  • CCC Certificate: CCC_2009010303326655
  • cULus Certificate: cULus508_20120829-E140448
  • Data Sheet, Technical Information: 2CDC112206D0201
  • Declaration of Conformity - CE: 1SVD981014-0000
  • EAC Certificate: EAC_RU_C-DE.ME77.B.01012
  • RMRS Certificate: RMRS_12.04009.250
  • RoHS Information: 1SAA981057-4402
  • E-nummer: 3860599
  • ETIM 4: EC001441 - Phase monitoring relay
  • ETIM 5: EC001441 - Phase monitoring relay
  • ETIM 6: EC001441 - Phase monitoring relay
  • Object Classification Code: B
Santa Clara Systems specializes in hard-to-find parts. Choose from our overstock inventory and save on CM-PAS.41P . Santa Clara Systems carries 36,673 items from ABB.
  • 0.1-30 S). A Sealable Transparent Cover For Protection Against Unauthorized Changes Is Available As Accessory. The Device Offers Maintenance Free Easy Connect Technology With Push-In Terminals. The Device Offers Screw Connection Technology With Double-Chamber Cage Connection Terminals.
  • The Cm-Pas.41p Relay Is From The Cm Three-Phase Monitors Range. This Relay Operates With A Rated Control Supply Voltage / Three-Phase Measuring Voltage Of 300-500 V Ac And Has A 2 C/o Output With Contacts Rated At 250 V / 4 A. The Cm-Pas.41p Monitors The Phase Parameters Phase Failure
  • Phase Sequence And Phase Unbalance. An On-Delay Is Adjustable Over A Range Of Instantaneous To 30 S (0

Alternates

  • 1SVR740774R3300
  • CM PAS.41P
  • CMPAS.41P
  • CMPAS41P

Common Typos

  • CM-PA5.41P
  • CM-PA5.4IP
  • CM-PA5.4LP
  • CM-PAS.4IP
  • CM-PAS.4LP

Appended Numbers

  • CM-PAS.41P-A
  • CM-PAS.41P-B
  • CM-PAS.41P-C
  • CM-PAS.41P-D
  • CM-PAS.41P-E
  • CM-PAS.41P-F
  • CM-PAS.41P-G
  • CM-PAS.41P-H
  • CM-PAS.41P-I
  • CM-PAS.41P-J
  • CM-PAS.41P-K
  • CM-PAS.41P-L
  • CM-PAS.41P-M
  • CM-PAS.41P-N
  • CM-PAS.41P-O
  • CM-PAS.41P-P
  • CM-PAS.41P-Q
  • CM-PAS.41P-R
  • CM-PAS.41P-S
  • CM-PAS.41P-T
  • CM-PAS.41P-U
  • CM-PAS.41P-V
  • CM-PAS.41P-W
  • CM-PAS.41P-X
  • CM-PAS.41P-Y
  • CM-PAS.41P-Z

More Products Like This

Customers Are Also Buying

We Deliver!

Late West Coast Shipping Hours
Late West Coast Shipping (5PM PST)
Drop-Ship and Blind-Ship Specialists
Expertly Packed Static-Limited
Same-Day Service
In-House Courier
visa credit card logo mastercard credit card logo discover credit card logo american express credit card logo

Customers we work with

3M logo
Kaiser Permanente logo
Safeway Logo
Georgia-Pacific logo
Coca Cola logo
duke energy logo
BART logo
Pepsi logo
LA DWP logo
US Navy logo
Dean Foods logo
ConAgra Brands logo