1SBL121004M2601
Product Summary:
- Extended Product Type: AS16-30-01S-26M
- Product ID: 1SBL121004M2601
- EAN: 3471523055261
- Minimum Order Quantity: 40 piece
- Customs Tariff Number: 85369085
Let Us Find It
or
CALL 1 (888) 450-0301
- Description: AS16-30-01S-26M 230V50/60HZ Contactor
- Rated Impulse Withstand Voltage (Uimp): 6 kV
- Maximum Mechanical Switching Frequency: 3600 cycles per hour
- Rated Control Circuit Voltage (Uc): 50 Hz 230 V 60 Hz 230 V
- Operate Time: Between Coil De-energization and NC Contact Closing 7 ... 22 ms Between Coil De-energization and NO Contact Opening 5 ... 19 ms Between Coil Energization and NC Contact Opening 6 ... 18 ms Between Coil Energization and NO Contact Closing 9 ... 24 ms
- Connecting Capacity Main Circuit: Flexible with Insulated Ferrule 1/2x 0.75 ... 1.5 mm² Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² Rigid 1/2x 0.75 ... 2.5 mm²
- Connecting Capacity Auxiliary Circuit: Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² Flexible with Insulated Ferrule 1/2x 0.75 ... 1.5 mm² Rigid 1/2x 0.75 ... 2.5 mm²
- Connecting Capacity Control Circuit: Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² Flexible with Insulated Ferrule 1/2x 0.75 ... 1.5 mm² Rigid 1/2x 0.75 ... 2.5 mm²
- Wire Stripping Length: Auxiliary Circuit 10 mm Control Circuit 10 mm Main Circuit 10 mm
- Degree of Protection: acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20 acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20
- Terminal Type: Spring Terminals
- Number of Main Contacts NO: 3
- Climatic Withstand: Category B according to IEC 60947-1 Annex Q
- Maximum Operating Altitude Permissible: 3000 m
- Resistance to Vibrations acc. to IEC 60068-2-6: 5 ... 300 Hz 3 g Closed position / 2 g Open position
- Resistance to Shock acc. to IEC 60068-2-27: Closed, Shock Direction: B1 10 g Closed, Shock Direction: C1 20 g Closed, Shock Direction: C2 20 g Open, Shock Direction: B1 5 g Open, Shock Direction: C1 9 g Open, Shock Direction: C2 14 g Shock Direction: A 20 g Shock Direction: B2 15 g
- RoHS Status: Following EU Directive 2011/65/EC
- Ambient Air Temperature: Close to Contactor for Storage -60 ... +80 °C Close to Contactor Fitted with Thermal O/L Relay -25 ... +60 °C Close to Contactor without Thermal O/L Relay -40 ... +70 °C
- General Use Rating UL/CSA: (600 V AC) 15.2 A
- Horsepower Rating UL/CSA: (120 V AC) Single Phase 3/4 Hp (240 V AC) Single Phase 2 Hp (200 ... 208 V AC) Three Phase 3 Hp (220 ... 240 V AC) Three Phase 5 Hp (440 ... 480 V AC) Three Phase 10 Hp (550 ... 600 V AC) Three Phase 10 Hp
- Instructions and Manuals: 1SBC101020M9701
- CB Certificate: CB_CN13475-M1
- CCC Certificate: CCC_2007010309251577
- cUL Certificate: UL_20110325-E312527
- Data Sheet, Technical Information: 1SBC100173C0201
- Declaration of Conformity - CE: 1SBD250014U1000
- GOST Certificate: GOST_POCCCNME77B07822.pdf
- RoHS Information: 1SBD251005E1002
- ETIM 4: EC000066 - Magnet contactor, AC-switching
- ETIM 5: EC000066 - Magnet contactor, AC-switching
- ETIM 6: EC000066 - Power contactor, AC switching
- UNSPSC: 39121529
- Object Classification Code: Q
- Extended Product Type: AS16-30-01S-26M
- Product ID: 1SBL121004M2601
- EAN: 3471523055261
- Minimum Order Quantity: 40 piece
- Customs Tariff Number: 85369085
- EAN: 3471523055261
- Product Net Depth: 72.5 mm
- Product Net Height: 68 mm
- Product Net Weight: 0.220 kg
- Product Net Width: 45 mm
- Package Level 1 Width: 293 mm
- Package Level 1 Length: 167 mm
- Package Level 1 Height: 250 mm
- Package Level 1 Gross Weight: 8.8 kg
- Package Level 1 EAN: 3471523055261
- Package Level 3 Units: 960 piece
- Package Level 1 Units: 40 piece
- Number of Main Contacts NC: 0
- Number of Auxiliary Contacts NO: 0
- Number of Auxiliary Contacts NC: 1
- Standards: IEC 60947-1 / 60947-4-1 and EN 60947-1 / 60947-4-1, UL 508, CSA C22.2 N°14
- Rated Operational Voltage: Auxiliary Circuit 690 V Main Circuit 690 V
- Rated Frequency (f): Auxiliary Circuit 50 / 60 Hz Main Circuit 50 / 60 Hz
- Conventional Free-air Thermal Current (Ith): acc. to IEC 60947-4-1, Open Contactors q = 40 °C 22 A acc. to IEC 60947-5-1, q = 40 °C 10 A
- Rated Operational Current AC-1 (Ie): (690 V) 40 °C 22 A (690 V) 60 °C 17 A (690 V) 70 °C 14 A
- Rated Operational Current AC-3 (Ie): (220 / 230 / 240 V) 60 °C 15.7 A (380 / 400 V) 60 °C 15.5 A (415 V) 60 °C 15.5 A (440 V) 60 °C 13.6 A (500 V) 60 °C 12.5 A (690 V) 60 °C 9 A
- Rated Operational Power AC-3 (Pe): (220 / 230 / 240 V) 4 kW (400 V) 7.5 kW (415 V) 7.5 kW (440 V) 7.5 kW (500 V) 7.5 kW (690 V) 7.5 kW
- Rated Operational Current AC-15 (Ie): (220 / 240 V) 4 A (24 / 127 V) 6 A (400 / 440 V) 3 A (500 V) 2 A (690 V) 2 A
- Rated Short-time Withstand Current (Icw): at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 124 A at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 22 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 55 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 250 A at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 75 A for 0.1 s 140 A for 1 s 100 A
- Maximum Breaking Capacity: cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 155 A cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 90 A
- Maximum Electrical Switching Frequency: AC-1 600 cycles per hour AC-15 1200 cycles per hour AC-2 / AC-4 300 cycles per hour AC-3 1200 cycles per hour DC-13 900 cycles per hour
- Rated Operational Current DC-13 (Ie): (110 V) 0.55 A / 60 W (125 V) 0.55 A / 69 W (220 V) 0.27 A / 60 W (24 V) 6 A / 144 W (250 V) 0.27 A / 68 W (48 V) 2.8 A / 134 W (72 V) 1 A / 72 W
- Rated Insulation Voltage (Ui): acc. to UL/CSA 600 V acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V acc. to IEC 60947-5-1 and VDE 0110 (Gr. C) 690 V
Santa Clara Systems specialises in hard-to-find parts. Choose from our overstock inventory and save on 1SBL121004M2601 . Santa Clara Systems carries 36,195 items from ABB.
- Front-Mounted Add-On Auxiliary Contact Blocks (Mechanically-Linked Auxiliary Contacts Compliant With Annex L Of Iec 60947-5-1. N.C. Mirror Contacts Compliant With Annex F Of Iec 60947-4-1) - Control Circuit: Ac Operated With Laminated Magnet Circuit - Accessories: A Wide Range Of Accessories Is Available.
Alternates
- AS16-30-01S-26M
- AS16 30 01S 26M
- AS163001S26M
Common Types
- 1SBL121004M260I
- 1SBL121004M260L
- 1SBL121004M26O1
- 1SBL121004M26OI
- 1SBL121004M26OL
- 1SBL121004M2G01
- 1SBL121004M2G0I
- 1SBL121004M2G0L
- 1SBL121004M2GO1
- 1SBL121004M2GOI
- 1SBL121004M2GOL
- 1SBL121004MZ601
- 1SBL121004MZ60I
- 1SBL121004MZ60L
- 1SBL121004MZ6O1
- 1SBL121004MZ6OI
- 1SBL121004MZ6OL
- 1SBL121004MZG01
- 1SBL121004MZG0I
- 1SBL121004MZG0L
- 1SBL121004MZGO1
- 1SBL121004MZGOI
- 1SBL121004MZGOL
- 1SBL1210O4M2601
- 1SBL1210O4M260I
Appended Numbers
- 1SBL121004M2601-A
- 1SBL121004M2601-B
- 1SBL121004M2601-C
- 1SBL121004M2601-D
- 1SBL121004M2601-E
- 1SBL121004M2601-F
- 1SBL121004M2601-G
- 1SBL121004M2601-H
- 1SBL121004M2601-I
- 1SBL121004M2601-J
- 1SBL121004M2601-K
- 1SBL121004M2601-L
- 1SBL121004M2601-M
- 1SBL121004M2601-N
- 1SBL121004M2601-O
- 1SBL121004M2601-P
- 1SBL121004M2601-Q
- 1SBL121004M2601-R
- 1SBL121004M2601-S
- 1SBL121004M2601-T
- 1SBL121004M2601-U
- 1SBL121004M2601-V
- 1SBL121004M2601-W
- 1SBL121004M2601-X
- 1SBL121004M2601-Y
- 1SBL121004M2601-Z
More Products Like This
-
1SBL121004M2610
ABB
-
1SBL121004M2632
ABB
-
1SBL121004R2601
ABB
-
1SBL121004R2610
ABB
Customers Are Also Buying
-
872C-A5N18-A5
Allen Bradley
-
X-307923
Allen Bradley
-
990 XCP 980 00 (BATTERY)
Modicon
-
800F-PX01
Allen Bradley
We Deliver!

- ✓ Late West Coast Shipping (5PM PST)
- ✓ Drop-Ship and Blind-Ship Specialists
- ✓ Expertly Packed Static-Limited
- ✓ Same-Day Service
- ✓ In-House Courier Domestic and International