• ABB AF12-30-22-13 AF12-30-22-13 100-250V50/60HZ-DC Contactor Product Image
  • Abb AF12-30-22-13 Barcode

AF12-30-22-13

Let Us Find It

Current response time:

By 5AM PT on Tuesday
  • Description: AF12-30-22-13 100-250V50/60HZ-DC Contactor
  • Product ID: 1SBL157001R1322
  • Extended Product Type: 1SBL157001R1322
  • Product Net Weight: 0.320 kg
  • Product Net Width: 45 mm
  • Product Net Height: 86 mm
  • Product Net Depth: 110.5 mm
  • Degree of Protection: acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20 acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20
  • Ambient Air Temperature: Close to Contactor for Storage -60...+80 C Close to Contactor Fitted with Thermal O/L Relay -25 ... +60 C Close to Contactor without Thermal O/L Relay -40 ... +70 C
  • Standards: IEC 60947-1 / 60947-4-1 and EN 60947-1 / 60947-4-1, UL 508, CSA C22.2 N14
  • Rated Impulse Withstand Voltage (U<sub>imp</sub>): 6 kV
  • Rated Insulation Voltage (U<sub>i</sub>): acc. to UL/CSA 600 V acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V
  • Terminal Type: Screw Terminals
  • Rated Frequency (f): Auxiliary Circuit 50 / 60 Hz Main Circuit 50 / 60 Hz
  • Number of Auxiliary Contacts NO: 2
  • Number of Auxiliary Contacts NC: 2
  • Connecting Capacity Main Circuit: Flexible with Insulated Ferrule 1x 0.75...4 mm Flexible with Insulated Ferrule 2x 0.75...2.5 mm Flexible with Ferrule 1/2x 0.75...6 mm Rigid 1/2x 1...6 mm
  • GOST Certificate: GOST_POCCFR.ME77.B07175.pdf
  • Maximum Operating Altitude Permissible: 3000 m
  • Rated Control Circuit Voltage (U<sub>c</sub>): 50 Hz 100 ... 250 V 60 Hz 100 ... 250 V DC Operation 100 ... 250 V
  • Climatic Withstand: Category B according to IEC 60947-1 Annex Q
  • Tightening Torque UL/CSA: Auxiliary Circuit 11 in&#183;lb Control Circuit 11 in&#183;lb Main Circuit 13 in&#183;lb
  • Maximum Mechanical Switching Frequency: 3600 cycles per hour
  • Connecting Capacity Auxiliary Circuit: Flexible with Ferrule 1/2x 0.75 ... 2.5 mm Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm Rigid 1/2x 1...2.5 mm
  • Operate Time: Between Coil De-energization and NC Contact Closing 13...98 ms Between Coil De-energization and NO Contact Opening 11...95 ms Between Coil Energization and NC Contact Opening 38...90 ms Between Coil Energization and NO Contact Closing 40...95 ms
  • Wire Stripping Length: Auxiliary Circuit 10 mm Control Circuit 10 mm Main Circuit 10 mm
  • Number of Main Contacts NO: 3
  • GL Certificate: DNV-GL_E13871
  • Number of Main Contacts NC: 0
  • Maximum Breaking Capacity: cos phi=0.45 (cos phi=0.35 for Ie &gt; 100 A) at 440 V 250 A cos phi=0.45 (cos phi=0.35 for Ie &gt; 100 A) at 690 V 106 A
  • Connecting Capacity Control Circuit: Flexible with Ferrule 1/2x 0.75 ... 2.5 mm Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm Rigid 1/2x 1 ... 2.5 mm
  • Horsepower Rating UL/CSA: (120 V AC) Single Phase 1 Hp (240 V AC) Single Phase 2 Hp (200 ... 208 V AC) Three Phase 3 Hp (220 ... 240 V AC) Three Phase 3 Hp (440 ... 480 V AC) Three Phase 7-1/2 Hp (550 ... 600 V AC) Three Phase 10 Hp
  • General Use Rating UL/CSA: (600 V AC) 28 A
  • EAN: 3471523110533
  • Minimum Order Quantity: 1 piece
  • Customs Tariff Number: 85369085
  • Package Level 1 Width: 87 mm
  • Package Level 1 Length: 113 mm
  • Package Level 1 Height: 47 mm
  • Package Level 1 Gross Weight: 0.32 kg
  • Package Level 1 EAN: 3471523110533
  • Package Level 2 Units: 36 piece
  • Package Level 2 Width: 250 mm
  • Package Level 2 Length: 300 mm
  • Package Level 2 Height: 315 mm
  • Package Level 3 Units: 864 piece
  • Package Level 1 Units: 1 piece
  • Rated Operational Voltage: Auxiliary Circuit 690 V Main Circuit 690 V
  • Conventional Free-air Thermal Current (I<sub>th</sub>): acc. to IEC 60947-4-1, Open Contactors q = 40 C 35 A acc. to IEC 60947-5-1, q = 40 C 16 A
  • Rated Operational Current AC-1 (I<sub>e</sub>): (690 V) 40 C 28 A (690 V) 60 C 28 A (690 V) 70 C 24 A
  • Rated Operational Current AC-3 (I<sub>e</sub>): (220 / 230 / 240 V) 60 C 12 A (380 / 400 V) 60 C 12 A (415 V) 60 C 12 A (440 V) 60 C 12 A (500 V) 60 C 12.5 A (690 V) 60 C 9 A
  • Rated Operational Power AC-3 (P<sub>e</sub>): (220 / 230 / 240 V) 3 kW (380 / 400 V) 5.5 kW (400 V) 5.5 kW (415 V) 5.5 kW (440 V) 5.5 kW (500 V) 7.5 kW (690 V) 7.5 kW
  • Rated Operational Current AC-15 (I<sub>e</sub>): (220 / 240 V) 4 A (24 / 127 V) 6 A (400 / 440 V) 3 A (500 V) 2 A (690 V) 2 A
  • Rated Short-time Withstand Current (I<sub>cw</sub>): at 40 C Ambient Temp, in Free Air, from a Cold State 10 s 150 A at 40 C Ambient Temp, in Free Air, from a Cold State 15 min 35 A at 40 C Ambient Temp, in Free Air, from a Cold State 1 min 60 A at 40 C Ambient Temp, in Free Air, from a Cold State 1 s 300 A at 40 C Ambient Temp, in Free Air, from a Cold State 30 s 80 A for 0.1 s 140 A for 1 s 100 A
  • Maximum Electrical Switching Frequency: AC-1 600 cycles per hour AC-15 1200 cycles per hour AC-2 / AC-4 300 cycles per hour AC-3 1200 cycles per hour DC-13 900 cycles per hour
  • Rated Operational Current DC-13 (I<sub>e</sub>): (110 V) 0.55 A / 60 W (125 V) 0.55 A / 69 W (220 V) 0.27 A / 60 W (24 V) 6 A / 144 W (250 V) 0.27 A / 68 W (400 V) 0.15 A / 60 W (48 V) 2.8 A / 134 W (500 V) 0.13 A / 65 W (600 V) 0.1 A / 60 W (72 V) 1 A / 72 W
  • Resistance to Vibrations acc. to IEC 60068-2-6: 5 ... 300 Hz 4 g closed position / 2 g open position
  • Resistance to Shock acc. to IEC 60068-2-27: Closed, Shock Direction: B1 25 g Open, Shock Direction: B1 5 g Shock Direction: A 30 g Shock Direction: B2 15 g Shock Direction: C1 25 g Shock Direction: C2 25 g
  • RoHS Status: Planned to follow EU Directive 2002/95/EC August 18, 2005 and amendment after 2008 Q1
  • Instructions and Manuals: 1SBC101027M6801
  • ABS Certificate: ABS_15-GE1349500-PDA_90682247
  • CB Certificate: CB_SE_70855M1
  • CCC Certificate: CCC_2010010304445624
  • cUL Certificate: UL_20091124-E312527-7-1
  • Data Sheet, Technical Information: 1SBC101406D0201
  • Declaration of Conformity - CE: 1SBD250000U1000
  • DNV Certificate: DNV-GL_E13871
  • EAC Certificate: EAC_RU C-FR ME77 B01010
  • LR Certificate: LRS_1300087E1
  • RINA Certificate: RINA_ELE084013XG
  • RMRS Certificate: RMRS_1400682124
  • RoHS Information: 1SBD251013E1000
  • ETIM 4: EC000066 - Magnet contactor, AC-switching
  • ETIM 5: EC000066 - Magnet contactor, AC-switching
  • ETIM 6: EC000066 - Power contactor, AC switching
  • UNSPSC: 39121529
  • Object Classification Code: Q
Santa Clara Systems specializes in hard-to-find parts. Choose from our overstock inventory and save on AF12-30-22-13 . Santa Clara Systems carries 36,673 items from ABB.
  • Side-Mounted Add-On Auxiliary Contact Blocks (Mechanically-Linked Auxiliary Contacts Compliant With Annex L Of Iec 60947-5-1 Including The &quot;mechanically Linked&quot; Symbol On The Contactor Side. N.c. Mirror Contacts Compliant With Annex F Of Iec 60947-4-1) - Control Circuit: Ac Or Dc Operated - Accessories: A Wide Range Of Accessories Is Available. Note: 2-Stack Contactors Available In Some Countries: Please Consult Your Abb Representative.
  • Af12 Contactors Are Used For Controlling Power Circuits Up To 690 V Ac And 220 V Dc. They Are Mainly Used For Controlling 3-Phase Motors
  • Non-Inductive Or Slightly Inductive Loads. Af... Contactors Include An Electronic Coil Interface Accepting A Wide Control Voltage Uc Min. ... Uc Max. Only Four Coils Cover Control Voltages Between 24...500 V 50/60 Hz Or 20...500 V Dc. Af Contactors Can Manage Large Control Voltage Variations. One Coil Can Be Used For Different Control Voltages Used Worldwide Without Any Coil Change. Af Contactors Have Built-In Surge Protection And Do Not Require Additional Surge Suppressors. The Af... Series 2-Stack 3-Pole Contactors Are Of The Block Type Design. - Main Poles And Auxiliary Contact Blocks: 3 Main Poles With A Non-Removable Front-Mounted 2 N.o. + 2 N.c. Auxiliary Contact Block

Alternates

  • 1SBL157001R1322
  • AF12 30 22 13
  • AF12302213

Common Typos

  • AF12-30-22-I3
  • AF12-30-22-L3
  • AF12-30-2Z-13
  • AF12-30-2Z-I3
  • AF12-30-2Z-L3
  • AF12-30-Z2-13
  • AF12-30-Z2-I3
  • AF12-30-Z2-L3
  • AF12-30-ZZ-13
  • AF12-30-ZZ-I3
  • AF12-30-ZZ-L3
  • AF12-3O-22-13
  • AF12-3O-22-I3
  • AF12-3O-22-L3
  • AF12-3O-2Z-13
  • AF12-3O-2Z-I3
  • AF12-3O-2Z-L3
  • AF12-3O-Z2-13
  • AF12-3O-Z2-I3
  • AF12-3O-Z2-L3
  • AF12-3O-ZZ-13
  • AF12-3O-ZZ-I3
  • AF12-3O-ZZ-L3
  • AF1Z-30-22-13
  • AF1Z-30-22-I3
  • AF1Z-30-22-L3

Appended Numbers

  • AF12-30-22-13-A
  • AF12-30-22-13-B
  • AF12-30-22-13-C
  • AF12-30-22-13-D
  • AF12-30-22-13-E
  • AF12-30-22-13-F
  • AF12-30-22-13-G
  • AF12-30-22-13-H
  • AF12-30-22-13-I
  • AF12-30-22-13-J
  • AF12-30-22-13-K
  • AF12-30-22-13-L
  • AF12-30-22-13-M
  • AF12-30-22-13-N
  • AF12-30-22-13-O
  • AF12-30-22-13-P
  • AF12-30-22-13-Q
  • AF12-30-22-13-R
  • AF12-30-22-13-S
  • AF12-30-22-13-T
  • AF12-30-22-13-U
  • AF12-30-22-13-V
  • AF12-30-22-13-W
  • AF12-30-22-13-X
  • AF12-30-22-13-Y
  • AF12-30-22-13-Z

More Products Like This

Customers Are Also Buying

We Deliver!

Late West Coast Shipping Hours
Late West Coast Shipping (5PM PST)
Drop-Ship and Blind-Ship Specialists
Expertly Packed Static-Limited
Same-Day Service
In-House Courier
visa credit card logo mastercard credit card logo discover credit card logo american express credit card logo

Customers we work with

3M logo
Kaiser Permanente logo
Safeway Logo
Georgia-Pacific logo
Coca Cola logo
duke energy logo
BART logo
Pepsi logo
LA DWP logo
US Navy logo
Dean Foods logo
ConAgra Brands logo