1SBL163001R8610
Product Summary:
- Extended Product Type: AL12-30-10 110V DC
- Product ID: 1SBL163001R8610
- EAN: 3471522273864
- Minimum Order Quantity: 1 piece
- Customs Tariff Number: 85369085
Let Us Find It
or
CALL 1 (888) 450-0301
- Description: AL12-30-10 110V DC Contactor
- Mechanical Durability: 10 million
- Maximum Mechanical Switching Frequency: 3600 cycles per hour
- Coil Operating Limits: (acc. to IEC 60947-4-1) 0.85 ... 1.1 x Uc (at ? ? 55 °C) °C
- Rated Control Circuit Voltage (Uc): DC Operation 110 V
- Coil Consumption: Average Holding Value, from Warm State 3 W Average Pull-in Value, from Cold State 3 W
- Operate Time: Between Coil Energization and NO Contact Closing 50 ... 100 ms Between Coil De-energization and NO Contact Opening 10 ... 17 ms Between Coil De-energization and NC Contact Closing 16 ... 27 ms Between Coil Energization and NC Contact Opening 20 ... 70 ms
- Connecting Capacity Main Circuit: Flexible with Cable End 0.75 ... 2.5 mm² Rigid Cable 1 ... 4 mm²
- Connecting Capacity Auxiliary Circuit: Flexible with Cable End 0.75 ... 2.5 mm² Rigid Cable 1 ... 4 mm²
- Degree of Protection: acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
- Connecting terminals (delivered in open position) Main poles: M 3.5 (+,-) pozidriv 2 screw with cable clamp
- Terminal Type: Screw Terminals
- Number of Main Contacts NO: 3
- Climatic Withstand: acc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II
- Maximum Operating Altitude Permissible: 3000 m
- Resistance to Shock acc. to IEC 60068-2-27: Closed, Shock Direction: A 20 g Open, Shock Direction: A 10 g Closed, Shock Direction: B1 15 g Open, Shock Direction: B1 5 g Shock Direction: B2 10 g Closed, Shock Direction: C1 20 g Open, Shock Direction: C1 8 g Closed, Shock Direction: C2 14 g Open, Shock Direction: C2 8 g
- RoHS Status: Following EU Directive 2002/95/EC August 18, 2005 and amendment
- Ambient Air Temperature: Close to Contactor Fitted with Thermal O/L Relay -25 ... +55 °C Close to Contactor for Storage -60 ... +80 °C Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... +55 °C Close to Contactor without Thermal O/L Relay (Uc) -40 ... +70 °C
- Instructions and Manuals: 1SBC101003M5501
- ASEFA Certificate: ASEFA_05103BT
- CB Certificate: CB_FR_617239A
- CCC Certificate: CCC_2004010304112227
- CSA Certificate: CSA_1041746
- cUL Certificate: UL_20160205-E312527-10-2
- Data Sheet, Technical Information: 1SBC100122C0202_Ch02
- Declaration of Conformity - CE: 1SBD250804U1000
- GL Certificate: GL_26144_05HH
- GOST Certificate: GOST_POCCFRME77B07175
- LOVAG Certificate: LOVAG_FR03022-FR03028
- RoHS Information: 1SBD350051R1000
- UL Listing Card: UL_E312527
- E-nummer: 3228423
- ETIM 4: EC000066 - Magnet contactor, AC-switching
- ETIM 5: EC000066 - Magnet contactor, AC-switching
- ETIM 6: EC000066 - Power contactor, AC switching
- UNSPSC: 39121529
- Object Classification Code: Q
- Extended Product Type: AL12-30-10 110V DC
- Product ID: 1SBL163001R8610
- EAN: 3471522273864
- Minimum Order Quantity: 1 piece
- Customs Tariff Number: 85369085
- EAN: 3471522273864
- Product Net Depth: 97 mm
- Product Net Height: 78 mm
- Product Net Weight: 0.520 kg
- Product Net Width: 44 mm
- Package Level 1 Width: 86 mm
- Package Level 1 Length: 141 mm
- Package Level 1 Height: 51 mm
- Package Level 1 Gross Weight: 0.52 kg
- Package Level 1 EAN: 3471522273864
- Package Level 2 Units: 28 piece
- Package Level 3 Units: 336 piece
- Package Level 1 Units: 1 piece
- Number of Main Contacts NC: 0
- Number of Auxiliary Contacts NO: 1
- Number of Auxiliary Contacts NC: 0
- Rated Operational Voltage: Main Circuit 690 V Auxiliary Circuit 690 V
- Rated Frequency (f): Supply Circuit 50 Hz Supply Circuit 60 Hz
- Conventional Free-air Thermal Current (Ith): acc. to IEC 60947-4-1, Open Contactors q = 40 °C 28 A acc. to IEC 60947-5-1, q = 40 °C 16 A
- Rated Operational Current AC-1 (Ie): (690 V) 40 °C 27 A (690 V) 55 °C 25 A (690 V) 70 °C 20 A
- Rated Operational Current AC-3 (Ie): (220 / 230 / 240 V) 55 °C 12 A (380 / 400 V) 55 °C 12 A (415 V) 55 °C 12 A (440 V) 55 °C 12 A (500 V) 55 °C 12 A (690 V) 55 °C 9 A
- Rated Operational Power AC-3 (Pe): (220 / 230 / 240 V) 3 kW (380 / 400 V) 5.5 kW (415 V) 5.5 kW (440 V) 5.5 kW (500 V) 7.5 kW (690 V) 7.5 kW
- Rated Breaking Capacity AC-3 acc. to IEC 60947-4-1: 8 x Ie AC-3
- Rated Making Capacity AC-3 acc. to IEC 60947-4-1: 10 x Ie AC-3
- Rated Operational Current AC-15 (Ie): (220 / 240 V) 4 A (24 / 127 V) 6 A (380 / 440 V) 3 A (500 V) 2 A (690 V) 2 A
- Short-Circuit Protective Devices: Auxiliary Circuit - gG Type Fuses 10 A gG Type Fuses 32 A
- Rated Short-time Withstand Current (Icw): at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 120 A at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 28 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 55 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 280 A at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 70 A for 0.1 s 140 A for 1 s 100 A
- Maximum Breaking Capacity: cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 250 A cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 100 A
- Maximum Electrical Switching Frequency: AC-1 600 cycles per hour AC-2 / AC-4 300 cycles per hour AC-3 1200 cycles per hour
- Rated Operational Current DC-13 (Ie): (125 V) 1.1 / 138 A (24 V) 6 / 144 A (250 V) 0.55 / 138 A (48 V) 2.8 / 134 A (72 V) 2 / 144 A
- Rated Insulation Voltage (Ui): acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V acc. to UL/CSA 600 V
- Rated Impulse Withstand Voltage (Uimp): 8 kV
Santa Clara Systems specialises in hard-to-find parts. Choose from our overstock inventory and save on 1SBL163001R8610 . Santa Clara Systems carries 36,195 items from ABB.
- 1 Built-In Auxiliary Contact
- Front And Side-Mounted Add-On Auxiliary Contact Blocks - Control Circuit: Dc Operated With Solid Core Magnet Circuit. The Polarity On The Coil Terminals (A1+ And A2-) Must Be Respected - Accessories: A Wide Range Of Accessories Is Available. Al... Contactors Are Fitted With Low Consumption Dc Coils And Are Suitable For A Direct Control By Plc Outputs.
Alternates
- AL12-30-10-86
- AL12 30 10 86
- AL12301086
Common Types
- 1SBL163001R861O
- 1SBL163001R86I0
- 1SBL163001R86IO
- 1SBL163001R86L0
- 1SBL163001R86LO
- 1SBL163001R8G10
- 1SBL163001R8G1O
- 1SBL163001R8GI0
- 1SBL163001R8GIO
- 1SBL163001R8GL0
- 1SBL163001R8GLO
- 1SBL163001RB610
- 1SBL163001RB61O
- 1SBL163001RB6I0
- 1SBL163001RB6IO
- 1SBL163001RB6L0
- 1SBL163001RB6LO
- 1SBL163001RBG10
- 1SBL163001RBG1O
- 1SBL163001RBGI0
- 1SBL163001RBGIO
- 1SBL163001RBGL0
- 1SBL163001RBGLO
- 1SBL16300IR8610
- 1SBL16300IR861O
Appended Numbers
- 1SBL163001R8610-A
- 1SBL163001R8610-B
- 1SBL163001R8610-C
- 1SBL163001R8610-D
- 1SBL163001R8610-E
- 1SBL163001R8610-F
- 1SBL163001R8610-G
- 1SBL163001R8610-H
- 1SBL163001R8610-I
- 1SBL163001R8610-J
- 1SBL163001R8610-K
- 1SBL163001R8610-L
- 1SBL163001R8610-M
- 1SBL163001R8610-N
- 1SBL163001R8610-O
- 1SBL163001R8610-P
- 1SBL163001R8610-Q
- 1SBL163001R8610-R
- 1SBL163001R8610-S
- 1SBL163001R8610-T
- 1SBL163001R8610-U
- 1SBL163001R8610-V
- 1SBL163001R8610-W
- 1SBL163001R8610-X
- 1SBL163001R8610-Y
- 1SBL163001R8610-Z
More Products Like This
-
1SBL163001R8601
ABB
-
1SBL163001R8622
ABB
-
1SBL163001R8101
ABB
-
1SBL163001R8122
ABB
Customers Are Also Buying
-
872C-N20NP18-D4
Allen Bradley
-
1756-BA2 (BATTERY)
Allen Bradley
-
855T-G24DN3
Allen Bradley
-
140M-C2E-C10
Allen Bradley
We Deliver!

- ✓ Late West Coast Shipping (5PM PST)
- ✓ Drop-Ship and Blind-Ship Specialists
- ✓ Expertly Packed Static-Limited
- ✓ Same-Day Service
- ✓ In-House Courier Domestic and International