• ABB 1SBL411001R5500 A75-30-00 500V 50Hz / 600V 60Hz Contactor Product Image
  • Abb 1SBL411001R5500 Barcode

1SBL411001R5500

Product Summary:

  • Extended Product Type: A75-30-00 500V 50Hz / 600V 60Hz
  • Product ID: 1SBL411001R5500
  • EAN: 3471522092557
  • Minimum Order Quantity: 1 piece
  • Customs Tariff Number: 85369085
Let Us Find It
           or           
  • Description: A75-30-00 500V 50Hz / 600V 60Hz Contactor
  • Rated Control Circuit Voltage (Uc): 50 Hz 500 V 60 Hz 600 V
  • Coil Consumption: Average Holding Value 50 Hz 18 V·A Average Holding Value 50 Hz 5.5 W Average Holding Value 60 Hz 18 V·A Average Holding Value 60 Hz 5.5 W Average Pull-in Value 50 Hz 180 V·A Average Pull-in Value 60 Hz 210 V·A
  • Operate Time: Between Coil Energization and NO Contact Closing 8 ... 27 ms Between Coil De-energization and NO Contact Opening 4 ... 11 ms
  • Connecting Capacity Main Circuit: Flexible with Cable End 6 ... 16 mm² Rigid Cable 6 ... 25 mm²
  • Connecting Capacity Auxiliary Circuit: Flexible with Cable End 0.75 ... 2.5 mm² Rigid Cable 1 ... 4 mm²
  • Degree of Protection: acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
  • Connecting terminals (delivered in open position) Main poles: M 6 (+,-) pozidriv 2 screws with 1x (13 x 10 mm) connector
  • Terminal Type: Screw Terminals
  • Number of Main Contacts NO: 3
  • Climatic Withstand: acc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II
  • Maximum Operating Altitude Permissible: 3000 m
  • Resistance to Shock acc. to IEC 60068-2-27: Shock Direction: A 20 g Closed, Shock Direction: B1 10 g Open, Shock Direction: B1 5 g Shock Direction: B2 15 g Shock Direction: C1 20 g Shock Direction: C2 20 g
  • RoHS Status: Following EU Directive 2002/95/EC August 18, 2005 and amendment
  • Ambient Air Temperature: Close to Contactor Fitted with Thermal O/L Relay -25 ... +55 °C Close to Contactor for Storage -60 ... +80 °C Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... +55 °C Close to Contactor without Thermal O/L Relay (Uc) -40 ... +70 °C
  • Instructions and Manuals: FPTC407700P0003
  • BV Certificate: BV_2634H07559D0
  • CB Certificate: CB_FR_602227A
  • CCC Certificate: CCC_2002010304016447
  • CSA Certificate: CSA_1033838_LR056745
  • cUL Certificate: UL_071301E39231
  • Data Sheet, Technical Information: 1SBC100122C0202_Ch02
  • Declaration of Conformity - CE: 1SBD250801U1000
  • DNV Certificate: DNV-GL_TAE00000TX
  • EAC Certificate: EAC_RU C-FR ME77 B01010
  • GL Certificate: DNV-GL_TAE00000TX
  • GOST Certificate: GOST_POCCFRME77B07175
  • LR Certificate: LRS_9830011E4
  • RINA Certificate: RINA_ELE128713XG001
  • RMRS Certificate: RMRS_0507015250
  • RoHS Information: 1SBD350054R1000
  • UL Certificate: UL_071301E39231
  • E-nummer: 3227828
  • ETIM 4: EC000066 - Magnet contactor, AC-switching
  • ETIM 5: EC000066 - Magnet contactor, AC-switching
  • ETIM 6: EC000066 - Power contactor, AC switching
  • UNSPSC: 39121529
  • Object Classification Code: Q
  • Extended Product Type: A75-30-00 500V 50Hz / 600V 60Hz
  • Product ID: 1SBL411001R5500
  • EAN: 3471522092557
  • Minimum Order Quantity: 1 piece
  • Customs Tariff Number: 85369085
  • EAN: 3471522092557
  • Product Net Depth: 108 mm
  • Product Net Height: 110 mm
  • Product Net Weight: 1.160 kg
  • Product Net Width: 70 mm
  • Package Level 1 Width: 140 mm
  • Package Level 1 Length: 146 mm
  • Package Level 1 Height: 96 mm
  • Package Level 1 Gross Weight: 1.16 kg
  • Package Level 1 EAN: 3471522092557
  • Package Level 2 Units: 20 piece
  • Package Level 3 Units: 160 piece
  • Package Level 1 Units: 1 piece
  • Number of Main Contacts NC: 0
  • Number of Auxiliary Contacts NO: 0
  • Number of Auxiliary Contacts NC: 0
  • Standards: Devices complying with international standards IEC 947-1 / 947-4-1, and European standards EN 60 947-1 / 60 947-4-1. Electromagnetic compatibility (EMC) acc. to amendment A11 to IEC 947-1; EN 60 947-1 and amendment 2 to IEC 947-4-1
  • Rated Operational Voltage: Main Circuit 1000 V
  • Conventional Free-air Thermal Current (Ith): acc. to IEC 60947-4-1, Open Contactors q = 40 °C 125 A
  • Rated Operational Current AC-1 (Ie): (690 V) 40 °C 125 A (690 V) 55 °C 105 A (690 V) 70 °C 85 A
  • Rated Operational Current AC-3 (Ie): (1000 V) 55 °C 28 A (220 / 230 / 240 V) 55 °C 75 A (380 / 400 V) 55 °C 75 A (415 V) 55 °C 72 A (440 V) 55 °C 70 A (500 V) 55 °C 65 A (690 V) 55 °C 46 A
  • Rated Operational Power AC-3 (Pe): (220 / 230 / 240 V) 22 kW (380 / 400 V) 37 kW (415 V) 40 kW (440 V) 40 kW (500 V) 45 kW (690 V) 40 kW
  • Rated Breaking Capacity AC-3 acc. to IEC 60947-4-1: 8 x Ie AC-3
  • Rated Making Capacity AC-3 acc. to IEC 60947-4-1: 10 x Ie AC-3
  • Short-Circuit Protective Devices: gG Type Fuses 160 A
  • Rated Short-time Withstand Current (Icw): at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 650 A at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 135 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 250 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1000 A at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 370 A
  • Maximum Breaking Capacity: cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1300 A cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 630 A
  • Maximum Electrical Switching Frequency: AC-1 600 cycles per hour AC-2 / AC-4 150 cycles per hour AC-3 600 cycles per hour
  • Rated Insulation Voltage (Ui): acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V acc. to UL/CSA 600 V
  • Rated Impulse Withstand Voltage (Uimp): 8 kV
  • Mechanical Durability: 10 million
  • Maximum Mechanical Switching Frequency: 3600 cycles per hour
  • Coil Operating Limits: (acc. to IEC 60947-4-1) 0.85 ... 1.1 x Uc (at ? ? 55 °C) °C
Santa Clara Systems specialises in hard-to-find parts. Choose from our overstock inventory and save on 1SBL411001R5500 . Santa Clara Systems carries 35,877 items from ABB.
  • Front And Side-Mounted Add-On Auxiliary Contact Blocks - Control Circuit: Ac Operated With Laminated Magnet Circuit - Accessories: A Wide Range Of Accessories Is Available.
  • A75 Contactors Are Mainly Used For Controlling 3-Phase Motors And Generally For Controlling Power Circuits Up To 690 V Ac / 1000 V Ac Or 220 V Dc. The Contactors Can Also Be Used For Many Other Applications Such As Isolation
  • Capacitor Switching
  • Lighting. The A... Series 1-Stack 3-Pole Contactors Are Of The Block Type Design. - Main Poles And Auxiliary Contact Blocks: 3 Main Poles
  • Alternates

    • A75-30-00-55
    • A75 30 00 55
    • A75300055

    Common Types

    • 1SBL411001R550O
    • 1SBL411001R55O0
    • 1SBL411001R55OO
    • 1SBL411001R5S00
    • 1SBL411001R5S0O
    • 1SBL411001R5SO0
    • 1SBL411001R5SOO
    • 1SBL411001RS500
    • 1SBL411001RS50O
    • 1SBL411001RS5O0
    • 1SBL411001RS5OO
    • 1SBL411001RSS00
    • 1SBL411001RSS0O
    • 1SBL411001RSSO0
    • 1SBL411001RSSOO
    • 1SBL41100IR5500
    • 1SBL41100IR550O
    • 1SBL41100IR55O0
    • 1SBL41100IR55OO
    • 1SBL41100IR5S00
    • 1SBL41100IR5S0O
    • 1SBL41100IR5SO0
    • 1SBL41100IR5SOO
    • 1SBL41100IRS500
    • 1SBL41100IRS50O

    Appended Numbers

    • 1SBL411001R5500-A
    • 1SBL411001R5500-B
    • 1SBL411001R5500-C
    • 1SBL411001R5500-D
    • 1SBL411001R5500-E
    • 1SBL411001R5500-F
    • 1SBL411001R5500-G
    • 1SBL411001R5500-H
    • 1SBL411001R5500-I
    • 1SBL411001R5500-J
    • 1SBL411001R5500-K
    • 1SBL411001R5500-L
    • 1SBL411001R5500-M
    • 1SBL411001R5500-N
    • 1SBL411001R5500-O
    • 1SBL411001R5500-P
    • 1SBL411001R5500-Q
    • 1SBL411001R5500-R
    • 1SBL411001R5500-S
    • 1SBL411001R5500-T
    • 1SBL411001R5500-U
    • 1SBL411001R5500-V
    • 1SBL411001R5500-W
    • 1SBL411001R5500-X
    • 1SBL411001R5500-Y
    • 1SBL411001R5500-Z

    Customers Are Also Buying

    We Deliver!

    Late West Coast Shipping Hours
    Late West Coast Shipping (5PM PST)
    Drop-Ship and Blind-Ship Specialists
    Expertly Packed Static-Limited
    Same-Day Service
    In-House Courier Domestic and International
    visa credit card logo mastercard credit card logo discover credit card logo american express credit card logo