• ABB 1SFL447101R1200 AF140-40-00-12 Contactor Product Image
  • Abb 1SFL447101R1200 Barcode

1SFL447101R1200

Product Summary:

  • Extended Product Type: AF140-40-00-12
  • Product ID: 1SFL447101R1200
  • EAN: 7320500505335
  • Minimum Order Quantity: 1 piece
  • Customs Tariff Number: 85364900
Let Us Find It
           or           
  • Description: AF140-40-00-12 Contactor
  • Rated Short-time Withstand Current (Icw): at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 1168 A at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 200 A at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 674 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1460 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 477 A
  • Maximum Breaking Capacity: cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 3000 A
  • Maximum Electrical Switching Frequency: AC-1 300 cycles per hour
  • Rated Insulation Voltage (Ui): acc. to UL/CSA 600 V acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V
  • Rated Impulse Withstand Voltage (Uimp): Main Circuit 8 kV
  • Mechanical Durability: 5 million
  • Maximum Mechanical Switching Frequency: 300 cycles per hour
  • Coil Operating Limits: (acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at ? ? 70 °C) °C
  • Rated Control Circuit Voltage (Uc): 60 Hz 48130 V 50 Hz 48130 V DC Operation 48130 V
  • Coil Consumption: Pull-in at Max. Rated Control Circuit Voltage 60 Hz 170 V·A Holding at Max. Rated Control Circuit Voltage DC 2.5 W Holding at Max. Rated Control Circuit Voltage 50 Hz 4 V·A Pull-in at Max. Rated Control Circuit Voltage DC 130 W Pull-in at Max. Rated Control Circuit Voltage 50 Hz 170 V·A Holding at Max. Rated Control Circuit Voltage 60 Hz 4 V·A
  • Operate Time: Between Coil Energization and NO Contact Closing 2055 ms Between Coil De-energization and NO Contact Opening 4070 ms
  • Connecting Capacity Main Circuit: Flexible 2x1070 mm² Rigid Cu-Cable 2x1095 mm²
  • Connecting Capacity Auxiliary Circuit: Solid 2x14 mm² Flexible with Insulated Ferrule 2x0.752.5 mm² Stranded 2x14 mm² Flexible 2x0.752.5 mm² Flexible with Ferrule 1x0.752.5 mm²
  • Degree of Protection: acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
  • Terminal Type: Double Clamp
  • Number of Main Contacts NO: 4
  • Maximum Operating Altitude Permissible: 3000 m
  • Ambient Air Temperature: Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25+50 °C Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40+70 °C Close to Contactor for Storage -40+70 °C
  • Maximum Operating Voltage UL/CSA: Main Circuit 600 V
  • ETIM 4: EC000066 - Magnet contactor, AC-switching
  • ETIM 5: EC000066 - Magnet contactor, AC-switching
  • Object Classification Code: Q
  • Extended Product Type: AF140-40-00-12
  • Product ID: 1SFL447101R1200
  • EAN: 7320500505335
  • Minimum Order Quantity: 1 piece
  • Customs Tariff Number: 85364900
  • EAN: 7320500505335
  • Product Net Depth: 128,1 mm
  • Product Net Height: 150 mm
  • Product Net Weight: 2.05 kg
  • Product Net Width: 120 mm
  • Package Level 1 Gross Weight: 2.25 kg
  • Package Level 1 Units: 1 piece
  • Number of Main Contacts NC: 0
  • Number of Auxiliary Contacts NO: 0
  • Number of Auxiliary Contacts NC: 0
  • Rated Operational Voltage: Main Circuit 690 V
  • Rated Frequency (f): Main Circuit 60 Hz
  • Conventional Free-air Thermal Current (Ith): acc. to IEC 60947-4-1, Open Contactors q = 40 °C 200 A
  • Rated Operational Current AC-1 (Ie): (690 V) 40 °C 200 A (690 V) 70 °C 160 A (690 V) 60 °C 175 A
  • Rated Operational Current AC-3 (Ie): (415 V) 55 °C 140 A (220 / 230 / 240 V) 55 °C 140 A (440 V) 55 °C 140 A (380 / 400 V) 55 °C 140 A
  • Rated Operational Power AC-3 (Pe): (220 / 230 / 240 V) 37 kW (380 / 400 V) 75 kW (440 V) 90 kW (415 V) 75 kW
  • Rated Breaking Capacity AC-3 acc. to IEC 60947-4-1: 8 x Ie AC-3
  • Rated Making Capacity AC-3 acc. to IEC 60947-4-1: 10 x Ie AC-3
  • Short-Circuit Protective Devices: gG Type Fuses 250 A
Santa Clara Systems specialises in hard-to-find parts. Choose from our overstock inventory and save on 1SFL447101R1200 . Santa Clara Systems carries 35,877 items from ABB.
  • 50/60 Hz And Dc
  • A 3-Phase Contactor Suitable For Various Applications Such As Motor Starting
  • Isolation
  • By-Pass And Distribution Application Up To Max 690 V. Operated With Wide Control Voltage Range 48-130 V
  • Alternates

    • AF140-40-00-12
    • AF140 40 00 12
    • AF140400012

    Common Types

    • 1SFL447101R120O
    • 1SFL447101R12O0
    • 1SFL447101R12OO
    • 1SFL447101R1Z00
    • 1SFL447101R1Z0O
    • 1SFL447101R1ZO0
    • 1SFL447101R1ZOO
    • 1SFL447101RI200
    • 1SFL447101RI20O
    • 1SFL447101RI2O0
    • 1SFL447101RI2OO
    • 1SFL447101RIZ00
    • 1SFL447101RIZ0O
    • 1SFL447101RIZO0
    • 1SFL447101RIZOO
    • 1SFL447101RL200
    • 1SFL447101RL20O
    • 1SFL447101RL2O0
    • 1SFL447101RL2OO
    • 1SFL447101RLZ00
    • 1SFL447101RLZ0O
    • 1SFL447101RLZO0
    • 1SFL447101RLZOO
    • 1SFL44710IR1200
    • 1SFL44710IR120O

    Appended Numbers

    • 1SFL447101R1200-A
    • 1SFL447101R1200-B
    • 1SFL447101R1200-C
    • 1SFL447101R1200-D
    • 1SFL447101R1200-E
    • 1SFL447101R1200-F
    • 1SFL447101R1200-G
    • 1SFL447101R1200-H
    • 1SFL447101R1200-I
    • 1SFL447101R1200-J
    • 1SFL447101R1200-K
    • 1SFL447101R1200-L
    • 1SFL447101R1200-M
    • 1SFL447101R1200-N
    • 1SFL447101R1200-O
    • 1SFL447101R1200-P
    • 1SFL447101R1200-Q
    • 1SFL447101R1200-R
    • 1SFL447101R1200-S
    • 1SFL447101R1200-T
    • 1SFL447101R1200-U
    • 1SFL447101R1200-V
    • 1SFL447101R1200-W
    • 1SFL447101R1200-X
    • 1SFL447101R1200-Y
    • 1SFL447101R1200-Z

    Customers Are Also Buying

    We Deliver!

    Late West Coast Shipping Hours
    Late West Coast Shipping (5PM PST)
    Drop-Ship and Blind-Ship Specialists
    Expertly Packed Static-Limited
    Same-Day Service
    In-House Courier Domestic and International
    visa credit card logo mastercard credit card logo discover credit card logo american express credit card logo