• ABB S201PR-K1 Miniature Circuit Breaker - S200PR - 1P - K - 1 A Product Image
  • Abb S201PR-K1 Barcode

S201PR-K1

Let Us Find It

Current response time:

By 5AM PT on Tuesday
  • Description: Miniature Circuit Breaker - S200PR - 1P - K - 1 A
  • Product ID: 2CDS271427R0217
  • Extended Product Type: 2CDS271427R0217
  • Product Net Weight: 0.14 kg
  • Product Net Width: 17.5 mm
  • Product Net Height: 100 mm
  • Product Net Depth: 71 mm
  • Degree of Protection: IP20
  • Ambient Air Temperature: Operation -25 ... +55 C Storage -40 ... +70 C
  • Standards: IEC/EN 60947-2 UL 1077 CSA 22.2 No. 235
  • Rated Impulse Withstand Voltage (U<sub>imp</sub>): 4 kV (6.2 kV @ sea level) (5.0 kV @ 2000 m)
  • Rated Insulation Voltage (U<sub>i</sub>): acc. to IEC/EN 60664-1 500 V
  • Number of Poles: 1
  • Terminal Type: Ring-Tongue Terminals
  • Rated Current (I<sub>n</sub>): 1 A
  • Rated Frequency (f): 50 Hz 60 Hz
  • Power Loss: 1.27 W at Rated Operating Conditions per Pole 1.27 W
  • Mounting on DIN Rail: TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715 TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
  • eClass: 7.0 27141901
  • Tightening Torque: 2.8 N&#183;m
  • Actuator Type: Insulation group II, black, sealable
  • Mounting Position: Any
  • Tripping Characteristic: K
  • Maximum Operating Voltage UL/CSA: 277 V AC
  • Contact Position Indication: Red ON / Green OFF
  • Tightening Torque UL/CSA: 25 in&#183;lb
  • Overvoltage Category: III
  • Environmental Conditions: 28 cycles with 55 C / 90-96 % and 25 C / 95-100 %
  • Housing Material: Insulation Group I, RAL 7035
  • Electrical Endurance: 20000 AC cycle
  • Mechanical Endurance: 20000 cycle
  • Connecting Capacity UL/CSA: Conductor 14-4 AWG
  • Operational Voltage: Minimum 12 V AC
  • Dielectric Test Voltage: 50 / 60 Hz, 1 min: 2 kV
  • Energy Limiting Class: 3
  • Screw Terminal Type: Ring-Tongue Terminal with Captive Screw
  • Interrupting Rating acc. to UL1077: 10 kA
  • EAN: 4016779846905
  • Minimum Order Quantity: 1 piece
  • Customs Tariff Number: 85362010
  • Package Level 1 Width: 121 mm
  • Package Level 1 Length: 191 mm
  • Package Level 1 Height: 82 mm
  • Package Level 1 Gross Weight: 1.45 kg
  • Package Level 1 EAN: 4016779848909
  • Package Level 2 EAN: 4016779982412
  • Package Level 1 Units: 10 piece
  • Resistance to Shock acc. to IEC 60068-2-27: 25g / 2 shocks / 13 ms
  • Resistance to Vibrations acc. to IEC 60068-2-6: 5g, 20 cycles at 5 ... 150 ... 5 Hz with load 0.8 In
  • Rated Operational Voltage: acc. to IEC 60947-2 230 V AC
  • Rated Ultimate Short-Circuit Breaking Capacity (I<sub>cu</sub>): 15 kA 15 kA (DC) kA
  • Rated Service Short-Circuit Breaking Capacity (I<sub>cs</sub>): 11.2 kA 15 kA
  • Pollution Degree: 2
  • Remarks: IP40 in enclosure with cover
  • Recommended Screw Driver: Pozidriv 2
  • Instructions and Manuals: 2CDC002138D0201
  • Data Sheet, Technical Information: 2CDC002138D0201
  • Declaration of Conformity - CE: 2CDK400586D2702
  • ETIM 4: EC000042 - Miniature circuit breaker (MCB)
  • ETIM 5: EC000042 - Miniature circuit breaker (MCB)
  • ETIM 6: EC000042 - Miniature circuit breaker (MCB)
  • UNSPSC: 39121614
  • Object Classification Code: F
Santa Clara Systems specializes in hard-to-find parts. Choose from our overstock inventory and save on S201PR-K1 . Santa Clara Systems carries 36,673 items from ABB.
  • Rtt Ul 1077
  • Ring Cable Lug
  • S201pr-K1 Mcb K-Char.
  • 10ka
  • 1a
  • 1p

Alternates

  • 2CDS271427R0217
  • S201PR K1
  • S201PRK1

Common Typos

  • S201PR-KI
  • S201PR-KL
  • S20IPR-K1
  • S20IPR-KI
  • S20IPR-KL
  • S20LPR-K1
  • S20LPR-KI
  • S20LPR-KL
  • S2O1PR-K1
  • S2O1PR-KI
  • S2O1PR-KL
  • S2OIPR-K1
  • S2OIPR-KI
  • S2OIPR-KL
  • S2OLPR-K1
  • S2OLPR-KI
  • S2OLPR-KL
  • SZ01PR-K1
  • SZ01PR-KI
  • SZ01PR-KL
  • SZ0IPR-K1
  • SZ0IPR-KI
  • SZ0IPR-KL
  • SZ0LPR-K1
  • SZ0LPR-KI
  • SZ0LPR-KL

Appended Numbers

  • S201PR-K1-A
  • S201PR-K1-B
  • S201PR-K1-C
  • S201PR-K1-D
  • S201PR-K1-E
  • S201PR-K1-F
  • S201PR-K1-G
  • S201PR-K1-H
  • S201PR-K1-I
  • S201PR-K1-J
  • S201PR-K1-K
  • S201PR-K1-L
  • S201PR-K1-M
  • S201PR-K1-N
  • S201PR-K1-O
  • S201PR-K1-P
  • S201PR-K1-Q
  • S201PR-K1-R
  • S201PR-K1-S
  • S201PR-K1-T
  • S201PR-K1-U
  • S201PR-K1-V
  • S201PR-K1-W
  • S201PR-K1-X
  • S201PR-K1-Y
  • S201PR-K1-Z

Customers Are Also Buying

We Deliver!

Late West Coast Shipping Hours
Late West Coast Shipping (5PM PST)
Drop-Ship and Blind-Ship Specialists
Expertly Packed Static-Limited
Same-Day Service
In-House Courier
visa credit card logo mastercard credit card logo discover credit card logo american express credit card logo

Customers we work with

3M logo
Kaiser Permanente logo
Safeway Logo
Georgia-Pacific logo
Coca Cola logo
duke energy logo
BART logo
Pepsi logo
LA DWP logo
US Navy logo
Dean Foods logo
ConAgra Brands logo