- Description: AF265-40-00-13 Contactor
- Product ID: 1SFL547102R1300
- Extended Product Type: 1SFL547102R1300
- Product Net Weight: 5.53 kg
- Product Net Width: 184,4 mm
- Product Net Height: 225,4 mm
- Product Net Depth: 180 mm
- Degree of Protection: acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
- Ambient Air Temperature: Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25+50 C Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40+70 C Close to Contactor for Storage -40+70 C
- Rated Impulse Withstand Voltage (U<sub>imp</sub>): Main Circuit 8 kV
- Rated Insulation Voltage (U<sub>i</sub>): acc. to UL/CSA 600 V acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V
- Terminal Type: Main Circuit: Bars
- Rated Frequency (f): Main Circuit 50 Hz
- Number of Auxiliary Contacts NO: 0
- Number of Auxiliary Contacts NC: 0
- Mechanical Durability: 5 million
- Connecting Capacity Main Circuit: Rigid Al-Cable 1x185240 mm Flexible 2x70185 mm Rigid Cu-Cable 1x6300 mm
- Maximum Operating Voltage UL/CSA: Main Circuit 600 V
- Maximum Operating Altitude Permissible: 3000 m
- Rated Control Circuit Voltage (U<sub>c</sub>): 60 Hz 100250 V 50 Hz 100250 V DC Operation 100250 V
- Maximum Mechanical Switching Frequency: 300 cycles per hour
- Connecting Capacity Auxiliary Circuit: Solid 2x14 mm Flexible with Insulated Ferrule 2x0.752.5 mm Stranded 2x14 mm Flexible 2x0.752.5 mm Flexible with Ferrule 2x0.752.5 mm
- Operate Time: Between Coil Energization and NO Contact Closing 3060 ms Between Coil De-energization and NO Contact Opening 4580 ms
- Number of Main Contacts NO: 4
- Number of Main Contacts NC: 0
- Short-Circuit Protective Devices: gG Type Fuses 630 A
- Maximum Breaking Capacity: cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 3800 A
- Coil Consumption: Pull-in at Max. Rated Control Circuit Voltage 60 Hz 385 V·A Holding at Max. Rated Control Circuit Voltage DC 4.5 W Holding at Max. Rated Control Circuit Voltage 50 Hz 17.5 V·A Pull-in at Max. Rated Control Circuit Voltage DC 410 W Pull-in at Max. Rated Control Circuit Voltage 50 Hz 385 V·A Holding at Max. Rated Control Circuit Voltage 60 Hz 17.5 V·A
- Coil Operating Limits: (acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at 70 C) C
- EAN: 7320500505137
- Minimum Order Quantity: 1 piece
- Customs Tariff Number: 85364900
- Package Level 1 Gross Weight: 6.36 kg
- Package Level 1 Units: 1 piece
- Rated Operational Voltage: Main Circuit 1000 V
- Conventional Free-air Thermal Current (I<sub>th</sub>): acc. to IEC 60947-4-1, Open Contactors q = 40 C 400 A
- Rated Operational Current AC-1 (I<sub>e</sub>): (690 V) 40 C 400 A (1000 V) 40 C 350 A (690 V) 70 C 290 A (690 V) 60 C 350 A (1000 V) 60 C 300 A (1000 V) 70 C 240 A
- Rated Operational Current AC-3 (I<sub>e</sub>): (220 / 230 / 240 V) 55 C 265 A (415 V) 55 C 265 A (440 V) 55 C 265 A (380 / 400 V) 55 C 265 A
- Rated Operational Power AC-3 (P<sub>e</sub>): (220 / 230 / 240 V) 75 kW (380 / 400 V) 132 kW (440 V) 160 kW (415 V) 132 kW
- Rated Breaking Capacity AC-3 acc. to IEC 60947-4-1: 8 x Ie AC-3
- Rated Making Capacity AC-3 acc. to IEC 60947-4-1: 10 x Ie AC-3
- Rated Short-time Withstand Current (I<sub>cw</sub>): at 40 C Ambient Temp, in Free Air, from a Cold State 10 s 2120 A at 40 C Ambient Temp, in Free Air, from a Cold State 15 min 400 A at 40 C Ambient Temp, in Free Air, from a Cold State 30 s 1224 A at 40 C Ambient Temp, in Free Air, from a Cold State 1 s 2650 A at 40 C Ambient Temp, in Free Air, from a Cold State 1 min 865 A
- Maximum Electrical Switching Frequency: AC-1 300 cycles per hour
- ETIM 4: EC000066 - Magnet contactor, AC-switching
- ETIM 5: EC000066 - Magnet contactor, AC-switching
- Object Classification Code: Q
Santa Clara Systems specializes in hard-to-find parts. Choose from our overstock inventory and save on AF265-40-00-13 . Santa Clara Systems carries 36,683 items from ABB.
- 50/60 Hz And Dc
- A 3-Phase Contactor Suitable For Various Applications Such As Motor Starting
- Isolation
- By-Pass And Distribution Application Up To Max 1000 V. Operated With Wide Control Voltage Range 100-250 V
Alternates
- 1SFL547102R1300
- AF265 40 00 13
- AF265400013
Common Typos
- AF265-40-00-I3
- AF265-40-00-L3
- AF265-40-0O-13
- AF265-40-0O-I3
- AF265-40-0O-L3
- AF265-40-O0-13
- AF265-40-O0-I3
- AF265-40-O0-L3
- AF265-40-OO-13
- AF265-40-OO-I3
- AF265-40-OO-L3
- AF265-4O-00-13
- AF265-4O-00-I3
- AF265-4O-00-L3
- AF265-4O-0O-13
- AF265-4O-0O-I3
- AF265-4O-0O-L3
- AF265-4O-O0-13
- AF265-4O-O0-I3
- AF265-4O-O0-L3
- AF265-4O-OO-13
- AF265-4O-OO-I3
- AF265-4O-OO-L3
- AF26S-40-00-13
- AF26S-40-00-I3
- AF26S-40-00-L3
Appended Numbers
- AF265-40-00-13-A
- AF265-40-00-13-B
- AF265-40-00-13-C
- AF265-40-00-13-D
- AF265-40-00-13-E
- AF265-40-00-13-F
- AF265-40-00-13-G
- AF265-40-00-13-H
- AF265-40-00-13-I
- AF265-40-00-13-J
- AF265-40-00-13-K
- AF265-40-00-13-L
- AF265-40-00-13-M
- AF265-40-00-13-N
- AF265-40-00-13-O
- AF265-40-00-13-P
- AF265-40-00-13-Q
- AF265-40-00-13-R
- AF265-40-00-13-S
- AF265-40-00-13-T
- AF265-40-00-13-U
- AF265-40-00-13-V
- AF265-40-00-13-W
- AF265-40-00-13-X
- AF265-40-00-13-Y
- AF265-40-00-13-Z
We Deliver!
- ✓ Late West Coast Shipping (5PM PST)
- ✓ Drop-Ship and Blind-Ship Specialists
- ✓ Expertly Packed Static-Limited
- ✓ Same-Day Service
- ✓ In-House Courier