Current response time:

5 Minutes 49 Seconds
  • Description: Digital Flow Sensor
  • Weight: Approx. 340 g (including mounting bracket)
  • Footnotes: *1 Liquid must allow for the passage of an ultrasonic pulse, as well as not contain large air pockets or excessive bubbles. Detection may be unstable on certain non-standard pipes (i.e. lined pipes) *2 Contact KEYENCE when the temperature of the pipe is greater than 85C 185F *3 The zero cut flow rate can be changed in the settings. When using the unit with a low flow rate range, perform an origin adjustment when the fluid is not moving if you change the zero cut flow rate. *4 This specification is valid when the flow velocity distribution is stable. This value does not take into account the effects of pulsation or fluctuations in flow velocity distribution due to facility factors. Convert the F.S. (full scale) listed in the table according to the rated flow range. *5 IO-Link: Compatible with Specification v1.1 / COM2 (38.4 kbps) The setting file can be downloaded from the KEYENCE website. If using the unit in the environment where downloading the file is not possible via internet, contact your nearest KEYENCE office. IO-Link is either registered trademarks or trademarks of PROFIBUS Nutzerorganisation e.V. (PNO) *6 When including the loads, please add 200 mA to this value.
  • Response time: 0.5 s / 1.0 s / 2.5 s / 5 s / 10 s / 30 s / 60 s
  • Supported pipe diameter: 1/4" (8 A), 13 to 16 (mm) 3/8" (10 A), 16 to 18 (mm)
  • Supported pipe materials: Metal pipe/Resin pipe*1
  • Supported fluids: Various liquid [i.e. water (including DI), oils, chemicals, etc.]*1
  • Supported fluid temperature: 0 to 85C 32 to 185F (No freezing on the pipe surface)*2
  • Maximum rated flow: 1/4" (8 A): 20 L/min, 5.2 G/min 3/8" (10 A): 30 L/min, 7.9 G/min
  • Zero cut flow rate: 1.0 L/min (Default)*3
  • Display method: Status indicator, output indicator, dual row display with 4-digit, 7 segment LED, stability level indicator
  • Display update cycle: Approx. 3 Hz
  • Display resolution: 0.01/0.1/1 (Default : 0.1) (L/min)
  • Repeatability: 0.5 s : 2.0%, 1 s:1.5%, 2.5 s : 1.0%, 5 s : 0.5%, 10 s : 0.35%, 30 s : 0.2%, 60 s : 0.15% (/F.S.*4(Specific to selected response time))
  • Hysteresis: Variable
  • Integrated flow unit display: 0.1/ 1/ 10/ 100/ 1000 (Default : 1) (L)
  • Integrated flow data storage cycle: Save to memory every 10 seconds
  • Memory backup: EEPROM (Data storage length: 10 years or longer, Data read/write frequency: 1 million times or more)
  • Power I/O connector: M12 4-pin connector
  • Input/Output (Selectable) - Output (ch.1/ch.2): Control output/ Pulse output/ Error output (Selectable, Default : ch.1 control output/ ch.2 not used), NPN/PNP setting switchable,open collector output 30 V or less, max. 100 mA/ch., residual voltage 2.5 V or less*5
  • Input/Output (Selectable) - Analog output (ch.2): 4 to 20 mA / 0 to 20 mA (Selectable, Default: not used), load resistance 500 - or less*5
  • Input/Output (Selectable) - External input (ch.2): Integrated flow reset input/ Flow rate zero input/ Origin adjustment input (Selectable, Default: not used), short-circuit current 1.5 mA or less, input time 20 ms or more*5
  • Power source - Power supply voltage: 20 to 30 VDC , ripple (P-P) 10% max, Class2/LPS
  • Power source - Current consumption: 100 mA or less (Load current excluded)*6
  • Protection circuit: Power supply reverse connection protection, power supply surge protection, each output short-circuit protection, each output surge protection
  • Environmental resistance - Enclosure rating: IP65/IP67 (IEC60529)
  • Environmental resistance - Ambient temperature: -10 to 60C 14 to 140F (No freezing)
  • Environmental resistance - Ambient humidity: 35 to 85%RH (No condensation)
  • Environmental resistance - Vibration resistance: 10 to 55 Hz, compound amplitude 1.5 mm 0.06", XYZ axes 2 hours for each axis
  • Environmental resistance - Shock resistance: 100 m/s2 16 ms pulse X, Y, Z 1000 times for each axis
  • Material - Sensor main unit: PPS/PES/PBT/SUS303/SUS304/SUSXM7
  • Material - Sensor surface: Rubber
  • Material - Mounting bracket: SUS304/PA/SUSXM7
Santa Clara Systems specializes in hard-to-find parts. Choose from our overstock inventory and save on FD-Q10C . Santa Clara Systems carries 2,096 items from Keyence.
We are in the process of adding data and downloadable material for this item. Please search similar items for more information related to this product.

Alternates

    Common Typos

    • FD-Q1OC
    • FD-QI0C
    • FD-QIOC
    • FD-QL0C
    • FD-QLOC

    Appended Numbers

    • FD-Q10C-A
    • FD-Q10C-B
    • FD-Q10C-C
    • FD-Q10C-D
    • FD-Q10C-E
    • FD-Q10C-F
    • FD-Q10C-G
    • FD-Q10C-H
    • FD-Q10C-I
    • FD-Q10C-J
    • FD-Q10C-K
    • FD-Q10C-L
    • FD-Q10C-M
    • FD-Q10C-N
    • FD-Q10C-O
    • FD-Q10C-P
    • FD-Q10C-Q
    • FD-Q10C-R
    • FD-Q10C-S
    • FD-Q10C-T
    • FD-Q10C-U
    • FD-Q10C-V
    • FD-Q10C-W
    • FD-Q10C-X
    • FD-Q10C-Y
    • FD-Q10C-Z

    Customers Are Also Buying

    We Deliver!

    Late West Coast Shipping Hours
    Late West Coast Shipping (5PM PST)
    Drop-Ship and Blind-Ship Specialists
    Expertly Packed Static-Limited
    Same-Day Service
    In-House Courier
    visa credit card logo mastercard credit card logo discover credit card logo american express credit card logo

    Customers we work with

    3M logo
    Kaiser Permanente logo
    Safeway Logo
    Georgia-Pacific logo
    Coca Cola logo
    duke energy logo
    BART logo
    Pepsi logo
    LA DWP logo
    US Navy logo
    Dean Foods logo
    ConAgra Brands logo