  • Description: module XPSAK - Emergency stop - 24 V AC DC
  • Product weight: 0.66 lb(US) (0.3 kg)
  • Range of product: Preventa Safety automation
  • IP degree of protection: IP20 (terminals) conforming to EN/IEC 60529, IP40 (enclosure) conforming to EN/IEC 60529
  • Standards: EN 1088/ISO 14119, EN/IEC 60204-1, EN/IEC 60947-5-1, EN/ISO 13850
  • [Ui] rated insulation voltage: 300 V (degree of pollution: 2) conforming to DIN VDE 0110 part 1, 300 V (degree of pollution: 2) conforming to IEC 60947-5-1
  • [Uimp] rated impulse withstand voltage: 4 kV overvoltage category III conforming to IEC 60947-5-1, 4 kV overvoltage category III conforming to DIN VDE 0110 part 1
  • Connections - terminals: Captive screw clamp terminals, clamping capacity: 2 x 0.5...2 x 1.5 mm flexible cable with cable end, with double bezel, Captive screw clamp terminals, clamping capacity: 1 x 0.14...1 x 2.5 mm flexible cable with cable end, with double bezel, Captive screw clamp terminals, clamping capacity: 1 x 0.14...1 x 2.5 mm solid cable with cable end, with double bezel, Captive screw clamp terminals, clamping capacity: 1 x 0.25...1 x 1.5 mm flexible cable with cable end, with double bezel, Captive screw clamp terminals, clamping capacity: 1 x 0.25...1 x 2.5 mm flexible cable with cable end, with double bezel, Captive screw clamp terminals, clamping capacity: 2 x 0.14...2 x 0.75 mm flexible cable with cable end, with double bezel, Captive screw clamp terminals, clamping capacity: 2 x 0.14...2 x 0.75 mm solid cable with cable end, with double bezel, Captive screw clamp terminals, clamping capacity: 2 x 0.25...2 x 1 mm flexible cable with cable end, with double bezel
  • Mounting support: 35 mm symmetrical DIN rail
  • [Ith] conventional free air thermal current: 18 A
  • [Uc] control circuit voltage: 24 V DC
  • [Us] rated supply voltage: 24 V AC (- 15...10 %), 24 V DC (- 15...10 %)
  • Associated fuse rating: 4 A fuse type gG or gL for relay output conforming to EN/IEC 60947-5-1, DIN VDE 0660 part 200, 6 A fuse type fast blow for relay output conforming to EN/IEC 60947-5-1, DIN VDE 0660 part 200
  • Breaking capacity: 1.5 A at 24 V (DC-13) time constant: 50 ms for relay output
  • Output type: Relay instantaneous opening 3 NO, volt-free
  • Synchronisation time between inputs: 2 or 4 s depending of wiring (automatic start), Unlimited (manual start)
  • Product or component type: Preventa safety module
  • Supply frequency: 50/60 Hz
  • Product certifications: CSA, TV, UL
  • Safety module name: XPSAK
  • power consumption in VA: <= 5 VA AC
  • Safety module application: For emergency stop, switch, sensing mat/edges or safety light curtain monitoring
  • Input protection type: Internal, electronic
  • Ambient air temperature for operation: 14...131 F (-10...55 C)
  • Function of module: Monitoring of electro-sensitive protection equipment (ESPE), Monitoring of a movable guard associated with 2 switches and automatic start, Monitoring of a movable guard, Emergency stop monitoring 1-channel wiring, Emergency stop with 2 NC contacts monitoring 2-channel wiring, Multiple emergency stop monitoring 2-channel wiring, Proximity sensor monitoring, Sensing mat and edges monitoring
  • Ambient air temperature for storage: -13...185 F (-25...85 C)
  • Safety level: Can reach PL e/category 4 conforming to EN/ISO 13849-1, Can reach SILCL 3 conforming to EN/IEC 62061
  • Line resistance: 28 Ohm
  • Safety reliability data: DC > 99 % conforming to EN/ISO 13849-1, MTTFd = 154.5 years conforming to EN/ISO 13849-1, PFHd = 7.39E-9 1/h conforming to EN/IEC 62061
  • Type of start: Configurable
  • Output thermal current: 6 A per relay relay output
  • Number of additional circuits: 1 NC + 4 solid state outputs
  • Minimum output current: 10 mA relay output
  • Minimum output voltage: 17 V relay output
  • Response time on input open: <= 40 ms
  • Local signalling: 4 LEDs
  • Current consumption: 30 mA at 24 V AC (on power supply)
Santa Clara Systems specializes in hard-to-find parts. Choose from our overstock inventory and save on XPSAK311144 . Santa Clara Systems carries 10,296 items from Telemecanique.
  • Module Xpsak - Emergency Stop - 24 V Ac Dc

Alternates

  • 44510-1201
  • SR120MP01

Common Typos

  • XPSAK311I44
  • XPSAK311L44
  • XPSAK31I144
  • XPSAK31II44
  • XPSAK31IL44
  • XPSAK31L144
  • XPSAK31LI44
  • XPSAK31LL44
  • XPSAK3I1144
  • XPSAK3I1I44
  • XPSAK3I1L44
  • XPSAK3II144
  • XPSAK3III44
  • XPSAK3IIL44
  • XPSAK3IL144
  • XPSAK3ILI44
  • XPSAK3ILL44
  • XPSAK3L1144
  • XPSAK3L1I44
  • XPSAK3L1L44
  • XPSAK3LI144
  • XPSAK3LII44
  • XPSAK3LIL44
  • XPSAK3LL144
  • XPSAK3LLI44
  • XPSAK3LLL44

Appended Numbers

  • XPSAK311144-A
  • XPSAK311144-B
  • XPSAK311144-C
  • XPSAK311144-D
  • XPSAK311144-E
  • XPSAK311144-F
  • XPSAK311144-G
  • XPSAK311144-H
  • XPSAK311144-I
  • XPSAK311144-J
  • XPSAK311144-K
  • XPSAK311144-L
  • XPSAK311144-M
  • XPSAK311144-N
  • XPSAK311144-O
  • XPSAK311144-P
  • XPSAK311144-Q
  • XPSAK311144-R
  • XPSAK311144-S
  • XPSAK311144-T
  • XPSAK311144-U
  • XPSAK311144-V
  • XPSAK311144-W
  • XPSAK311144-X
  • XPSAK311144-Y
  • XPSAK311144-Z

Customers Are Also Buying

We Deliver!

Late West Coast Shipping Hours
Late West Coast Shipping (5PM PST)
Drop-Ship and Blind-Ship Specialists
Expertly Packed Static-Limited
Same-Day Service
In-House Courier
visa credit card logo mastercard credit card logo discover credit card logo american express credit card logo

Customers we work with

3M logo
Kaiser Permanente logo
Safeway Logo
Georgia-Pacific logo
Coca Cola logo
duke energy logo
BART logo
Pepsi logo
LA DWP logo
US Navy logo
Dean Foods logo
ConAgra Brands logo