• ABB 1SBH101004M2653 NS53ES-26M 230V50/60HZ Contactor Relay Product Image
  • Abb 1SBH101004M2653 Barcode

1SBH101004M2653

Resumen del Producto:

  • Extended Product Type: NS53ES-26M
  • Product ID: 1SBH101004M2653
  • EAN: 3471523030268
  • Minimum Order Quantity: 20 piece
  • Customs Tariff Number: 85364900
Deje Que Lo Busquemos
           o           
  • Descripción: NS53ES-26M 230V50/60HZ Contactor Relay
  • Maximum Mechanical Switching Frequency: 3600 cycles per hour
  • Rated Control Circuit Voltage (Uc): 50 Hz 230 V 60 Hz 230 V
  • Operate Time: Between Coil De-energization and NC Contact Closing 7 ... 22 ms Between Coil De-energization and NO Contact Opening 5 ... 19 ms Between Coil Energization and NC Contact Opening 6 ... 18 ms Between Coil Energization and NO Contact Closing 9 ... 24 ms
  • Connecting Capacity Auxiliary Circuit: Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² Flexible with Insulated Ferrule 1/2x 0.75 ... 1.5 mm² Rigid 1/2x 0.75 ... 2.5 mm²
  • Connecting Capacity Control Circuit: Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² Flexible with Insulated Ferrule 1/2x 0.75 ... 1.5 mm² Rigid 1/2x 0.75 ... 2.5 mm²
  • Wire Stripping Length: Auxiliary Circuit 10 mm Control Circuit 10 mm
  • Degree of Protection: acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20 acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
  • Terminal Type: Spring Terminals
  • Climatic Withstand: Category B according to IEC 60947-1 Annex Q
  • Maximum Operating Altitude Permissible: 3000 m
  • Resistance to Vibrations acc. to IEC 60068-2-6: 5 ... 300 Hz 3 g Closed position / 2 g Open position
  • Resistance to Shock acc. to IEC 60068-2-27: Closed, Shock Direction: C1 19 g Closed, Shock Direction: C2 16 g Open, Shock Direction: C1 8 g Open, Shock Direction: C2 13 g Shock Direction: A 20 g Shock Direction: B1 5 g Shock Direction: B2 15 g
  • RoHS Status: Following EU Directive 2002/95/EC August 18, 2005 and amendment
  • Ambient Air Temperature: Close to Contactor for Storage -60 ... +80 °C Near Contactor for Operation in Free Air -40 ... +70 °C
  • Instructions and Manuals: 1SBC101020M9701
  • CB Certificate: CB_CN_32453
  • CCC Certificate: CCC_2007010305248106
  • cUL Certificate: UL_220108-E312527A
  • Data Sheet, Technical Information: 1SBC100173C0201
  • Declaration of Conformity - CE: 1SBD250016U1000
  • GOST Certificate: GOST_POCCCNME77B07821.pdf
  • RoHS Information: 1SBD251007E1000
  • ETIM 4: EC000196 - Contactor relay
  • ETIM 5: EC000196 - Contactor relay
  • ETIM 6: EC000196 - Contactor relay
  • UNSPSC: 39121500
  • Object Classification Code: K
  • Extended Product Type: NS53ES-26M
  • Product ID: 1SBH101004M2653
  • EAN: 3471523030268
  • Minimum Order Quantity: 20 piece
  • Customs Tariff Number: 85364900
  • EAN: 3471523030268
  • Product Net Depth: 110.7 mm
  • Product Net Height: 68 mm
  • Product Net Weight: 0.260 kg
  • Product Net Width: 45 mm
  • Package Level 1 Width: 293 mm
  • Package Level 1 Length: 128 mm
  • Package Level 1 Height: 247 mm
  • Package Level 1 Gross Weight: 5.2 kg
  • Package Level 1 EAN: 3471523030268
  • Package Level 3 Units: 640 piece
  • Package Level 1 Units: 20 piece
  • Number of Auxiliary Contacts NO: 5
  • Number of Auxiliary Contacts NC: 3
  • Standards: IEC 60947-5-1 and EN 60947-5-1, UL 508, CSA C22.2 N°14
  • Rated Operational Voltage: Auxiliary Circuit 690 V Main Circuit 690 V
  • Rated Frequency (f): Auxiliary Circuit 50 / 60 Hz
  • Conventional Free-air Thermal Current (Ith): acc. to IEC 60947-5-1, q = 40 °C 10 A
  • Rated Operational Current AC-15 (Ie): (220 / 240 V) 4 A (24 / 127 V) 6 A (400 / 440 V) 3 A (500 V) 2 A (690 V) 2 A
  • Rated Short-time Withstand Current (Icw): for 0.1 s 140 A for 1 s 100 A
  • Maximum Electrical Switching Frequency: AC-15 1200 cycles per hour DC-13 900 cycles per hour
  • Rated Operational Current DC-13 (Ie): (110 V) 0.55 A / 60 W (125 V) 0.55 A / 69 W (220 V) 0.27 A / 60 W (24 V) 6 A / 144 W (250 V) 0.27 A / 68 W (48 V) 2.8 A / 134 W (72 V) 1 A / 72 W
  • Rated Insulation Voltage (Ui): acc. to UL/CSA 600 V acc. to IEC 60947-5-1 and VDE 0110 (Gr. C) 690 V
  • Rated Impulse Withstand Voltage (Uimp): 6 kV
Santa Clara Systems se especializa en piezas difíciles de encontrar. Elija de nuestro inventario de exceso y ahorre en 1SBH101004M2653 . Santa Clara Systems tiene 35,877 artículos de ABB.
  • Ns... Contactor Relays Are Used For Switching Auxiliary Circuits And Control Circuits. The Ns..S Contactor Relays Are The Spring Terminal Version Of The Ns... Range. - Poles: 8-Pole Contactor Relays (Mechanically-Linked Auxiliary Contacts Compliant With Annex L Of Iec 60947-5-1 Including The &Quot;Mechanically Linked&Quot; Symbol On The Contactor Relay Side) - Control Circuit: Ac Operated With Laminated Magnet Circuit - Accessories: A Wide Range Of Accessories Is Available.

Alternativas

  • NS53ES-26M
  • NS53ES 26M
  • NS53ES26M

Errores Tipográficos Comunes

  • 1SBH101004M26S3
  • 1SBH101004M2G53
  • 1SBH101004M2GS3
  • 1SBH101004MZ653
  • 1SBH101004MZ6S3
  • 1SBH101004MZG53
  • 1SBH101004MZGS3
  • 1SBH1010O4M2653
  • 1SBH1010O4M26S3
  • 1SBH1010O4M2G53
  • 1SBH1010O4M2GS3
  • 1SBH1010O4MZ653
  • 1SBH1010O4MZ6S3
  • 1SBH1010O4MZG53
  • 1SBH1010O4MZGS3
  • 1SBH101O04M2653
  • 1SBH101O04M26S3
  • 1SBH101O04M2G53
  • 1SBH101O04M2GS3
  • 1SBH101O04MZ653
  • 1SBH101O04MZ6S3
  • 1SBH101O04MZG53
  • 1SBH101O04MZGS3
  • 1SBH101OO4M2653
  • 1SBH101OO4M26S3

Números Adjuntos

  • 1SBH101004M2653-A
  • 1SBH101004M2653-B
  • 1SBH101004M2653-C
  • 1SBH101004M2653-D
  • 1SBH101004M2653-E
  • 1SBH101004M2653-F
  • 1SBH101004M2653-G
  • 1SBH101004M2653-H
  • 1SBH101004M2653-I
  • 1SBH101004M2653-J
  • 1SBH101004M2653-K
  • 1SBH101004M2653-L
  • 1SBH101004M2653-M
  • 1SBH101004M2653-N
  • 1SBH101004M2653-O
  • 1SBH101004M2653-P
  • 1SBH101004M2653-Q
  • 1SBH101004M2653-R
  • 1SBH101004M2653-S
  • 1SBH101004M2653-T
  • 1SBH101004M2653-U
  • 1SBH101004M2653-V
  • 1SBH101004M2653-W
  • 1SBH101004M2653-X
  • 1SBH101004M2653-Y
  • 1SBH101004M2653-Z

Clientes También Están Comprando

Entrega que cumple con sus necesidades

Late West Coast Shipping Hours
Horas Tardes de Envió de la Costa Oeste (5PM Hora del Pacifico)
Especialistas en Entrega Directa y Entrega Ciega
Empacado por Expertos Estática Reducida
Servicio el Mismo Día
Mensajero Interno Nacional e Internacional
visa credit card logo mastercard credit card logo discover credit card logo american express credit card logo