• ABB AF09ZB-30-10-21 AF09ZB-30-10-21 24-60V50/60HZ 20-60VDC Contactor Product Image
  • Abb AF09ZB-30-10-21 Barcode

AF09ZB-30-10-21

Let Us Find It

Current response time:

By 5AM PT on Tuesday
  • Description: AF09ZB-30-10-21 24-60V50/60HZ 20-60VDC Contactor
  • Product ID: 1SBL136061R2110
  • Extended Product Type: 1SBL136061R2110
  • Product Net Weight: 0.310 kg
  • Product Net Width: 45 mm
  • Product Net Height: 86 mm
  • Product Net Depth: 77 mm
  • Degree of Protection: acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20 acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20
  • Ambient Air Temperature: Close to Contactor for Storage -60...+80 C Close to Contactor Fitted with Thermal O/L Relay -25 ... +60 C Close to Contactor without Thermal O/L Relay -40 ... +70 C
  • Rated Impulse Withstand Voltage (U<sub>imp</sub>): 6 kV
  • Rated Insulation Voltage (U<sub>i</sub>): acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V
  • Terminal Type: Screw Terminals
  • Rated Frequency (f): Auxiliary Circuit 50 / 60 Hz Main Circuit 50 / 60 Hz
  • Number of Auxiliary Contacts NO: 1
  • Number of Auxiliary Contacts NC: 0
  • Connecting Capacity Main Circuit: Flexible with Insulated Ferrule 1x 0.75...4 mm Flexible with Insulated Ferrule 2x 0.75...2.5 mm Flexible with Ferrule 1/2x 0.75...6 mm Rigid 1/2x 1...6 mm
  • GOST Certificate: GOST_POCCFR.ME77.B07175.pdf
  • Maximum Operating Altitude Permissible: 3000 m
  • Rated Control Circuit Voltage (U<sub>c</sub>): 50 Hz 24 ... 60 V 60 Hz 24 ... 60 V DC Operation 20 ... 60 V
  • Climatic Withstand: Category B according to IEC 60947-1 Annex Q
  • Maximum Mechanical Switching Frequency: 3600 cycles per hour
  • Operate Time: Between Coil De-energization and NC Contact Closing 13...98 ms Between Coil De-energization and NO Contact Opening 11...95 ms Between Coil Energization and NC Contact Opening 38...90 ms Between Coil Energization and NO Contact Closing 40...95 ms
  • Wire Stripping Length: Main Circuit 10 mm
  • Number of Main Contacts NO: 3
  • Number of Main Contacts NC: 0
  • Maximum Breaking Capacity: cos phi=0.45 (cos phi=0.35 for Ie &gt; 100 A) at 440 V 250 A cos phi=0.45 (cos phi=0.35 for Ie &gt; 100 A) at 690 V 106 A
  • Horsepower Rating UL/CSA: (120 V AC) Single Phase 3/4 Hp (240 V AC) Single Phase 1-1/2 Hp (200 ... 208 V AC) Three Phase 2 Hp (220 ... 240 V AC) Three Phase 2 Hp (440 ... 480 V AC) Three Phase 5 Hp (550 ... 600 V AC) Three Phase 7-1/2 Hp
  • General Use Rating UL/CSA: (600 V AC) 25 A
  • EAN: 3471523123519
  • Minimum Order Quantity: 1 piece
  • Customs Tariff Number: 85369085
  • Package Level 1 Width: 87 mm
  • Package Level 1 Length: 79 mm
  • Package Level 1 Height: 47 mm
  • Package Level 1 Gross Weight: 0.31 kg
  • Package Level 1 EAN: 3471523123519
  • Package Level 2 Units: 54 piece
  • Package Level 2 Width: 250 mm
  • Package Level 2 Length: 300 mm
  • Package Level 2 Height: 315 mm
  • Package Level 2 Gross Weight: 18.200 kg
  • Package Level 3 Units: 1296 piece
  • Package Level 1 Units: 1 piece
  • Rated Operational Voltage: Auxiliary Circuit 690 V Main Circuit 690 V
  • Conventional Free-air Thermal Current (I<sub>th</sub>): acc. to IEC 60947-4-1, Open Contactors q = 40 C 35 A acc. to IEC 60947-5-1, q = 40 C 16 A
  • Rated Operational Current AC-1 (I<sub>e</sub>): (690 V) 40 C 25 A (690 V) 60 C 25 A (690 V) 70 C 22 A
  • Rated Operational Current AC-3 (I<sub>e</sub>): (220 / 230 / 240 V) 60 C 9 A (380 / 400 V) 60 C 9 A (415 V) 60 C 9 A (440 V) 60 C 9 A (500 V) 60 C 9.5 A (690 V) 60 C 7 A
  • Rated Operational Power AC-3 (P<sub>e</sub>): (220 / 230 / 240 V) 2.2 kW (380 / 400 V) 4 kW (415 V) 4 kW (440 V) 4 kW (500 V) 5.5 kW (690 V) 5.5 kW
  • Rated Operational Current AC-15 (I<sub>e</sub>): (220 / 240 V) 4 A (24 / 127 V) 6 A (400 / 440 V) 3 A (500 V) 2 A (690 V) 2 A
  • Rated Short-time Withstand Current (I<sub>cw</sub>): at 40 C Ambient Temp, in Free Air, from a Cold State 10 s 150 A at 40 C Ambient Temp, in Free Air, from a Cold State 15 min 35 A at 40 C Ambient Temp, in Free Air, from a Cold State 1 min 60 A at 40 C Ambient Temp, in Free Air, from a Cold State 1 s 300 A at 40 C Ambient Temp, in Free Air, from a Cold State 30 s 80 A for 0.1 s 140 A for 1 s 100 A
  • Maximum Electrical Switching Frequency: AC-1 600 cycles per hour AC-15 1200 cycles per hour AC-2 / AC-4 300 cycles per hour AC-3 1200 cycles per hour DC-13 900 cycles per hour
  • Rated Operational Current DC-13 (I<sub>e</sub>): (110 V) 0.55 A / 60 W (125 V) 0.55 A / 69 W (220 V) 0.27 A / 60 W (24 V) 6 A / 144 W (250 V) 0.27 A / 68 W (400 V) 0.15 A / 60 W (48 V) 2.8 A / 134 W (500 V) 0.13 A / 65 W (600 V) 0.1 A / 60 W (72 V) 1 A / 72 W
  • RoHS Status: Planned to follow EU Directive 2002/95/EC August 18, 2005 and amendment after 2008 Q4
  • Instructions and Manuals: 1SBC101037M6801
  • CB Certificate: CB_SE_70855M1
  • CCC Certificate: CCC_2010010304445624
  • Data Sheet, Technical Information: 1SBC100174C0201
  • Declaration of Conformity - CE: 1SBD250002U1000
  • EAC Certificate: EAC_RU C-FR ME77 B01010
  • RoHS Information: 1SBD251017E1000
  • ETIM 4: EC000066 - Magnet contactor, AC-switching
  • ETIM 5: EC000066 - Magnet contactor, AC-switching
  • ETIM 6: EC000066 - Power contactor, AC switching
  • UNSPSC: 39121529
  • Object Classification Code: Q
Santa Clara Systems specializes in hard-to-find parts. Choose from our overstock inventory and save on AF09ZB-30-10-21 . Santa Clara Systems carries 36,673 items from ABB.
  • Class B. Reach The Highest Levels In Fire And Smoke Behaviour With Compliance To European Standard En 45545-2 (Hl2
  • Hl3 Hazard Levels) In Group Mounting. Reduce Train Energy With Lighter Devices And Requiring 68% Less Coil Energy Consumption In Operation. Electronic Coil Interface Handling Large Dc Voltage Fluctuation Voltage
  • Including Several Uc Dc Control Voltages Used For Battery Supply And Accepting Sinuso&#239;dal Ac 50/60 Hz Control Supplies Included Inside Ucmin.... Ucmax Voltage Range. Max Permitted Ac 50/60 Hz Control Voltage Must Not Be Exceeded (See Technical Data). Wide Range Of Auxiliary Contact Blocks For Front And Side Mounting.
  • Af09zb 3-Pole Contactors Comply With The Latest Railway Rolling Stock Standards And Allow Installation In Passengers Or Driver Cabins For Trains Frequently Operating Tunnels Or Undergrounds. They Are Mainly Used For Controlling 3-Phase Motors And Power Circuits Up To 690 V Ac And 220 V Dc. Improve The Compactness Of The Installations Thanks To Reduced Dimension And Side-By-Side Mounting Requiring Less 15% Width (Without Spacing) From -40 &#176;c Up To +70 &#176;c. Meet All Main Rollling Stocks Standards: Iec 60947-4-1
  • Iec 60947-5-1
  • Iec 60077-1/-2 And Applicable Parts Of En 50155 Standards
  • Shocks And Vibration Withstand Conforming To Iec 61373 Cat. 1

Alternates

  • 1SBL136061R2110
  • AF09ZB-30-10 21
  • AF09ZB-30-1021
  • AF09ZB 30 10 21
  • AF09ZB3010 21
  • AF09ZB301021

Common Typos

  • AF09ZB-30-10-2I
  • AF09ZB-30-10-2L
  • AF09ZB-30-10-Z1
  • AF09ZB-30-10-ZI
  • AF09ZB-30-10-ZL
  • AF09ZB-30-1O-21
  • AF09ZB-30-1O-2I
  • AF09ZB-30-1O-2L
  • AF09ZB-30-1O-Z1
  • AF09ZB-30-1O-ZI
  • AF09ZB-30-1O-ZL
  • AF09ZB-30-I0-21
  • AF09ZB-30-I0-2I
  • AF09ZB-30-I0-2L
  • AF09ZB-30-I0-Z1
  • AF09ZB-30-I0-ZI
  • AF09ZB-30-I0-ZL
  • AF09ZB-30-IO-21
  • AF09ZB-30-IO-2I
  • AF09ZB-30-IO-2L
  • AF09ZB-30-IO-Z1
  • AF09ZB-30-IO-ZI
  • AF09ZB-30-IO-ZL
  • AF09ZB-30-L0-21
  • AF09ZB-30-L0-2I
  • AF09ZB-30-L0-2L

Appended Numbers

  • AF09ZB-30-10-21-A
  • AF09ZB-30-10-21-B
  • AF09ZB-30-10-21-C
  • AF09ZB-30-10-21-D
  • AF09ZB-30-10-21-E
  • AF09ZB-30-10-21-F
  • AF09ZB-30-10-21-G
  • AF09ZB-30-10-21-H
  • AF09ZB-30-10-21-I
  • AF09ZB-30-10-21-J
  • AF09ZB-30-10-21-K
  • AF09ZB-30-10-21-L
  • AF09ZB-30-10-21-M
  • AF09ZB-30-10-21-N
  • AF09ZB-30-10-21-O
  • AF09ZB-30-10-21-P
  • AF09ZB-30-10-21-Q
  • AF09ZB-30-10-21-R
  • AF09ZB-30-10-21-S
  • AF09ZB-30-10-21-T
  • AF09ZB-30-10-21-U
  • AF09ZB-30-10-21-V
  • AF09ZB-30-10-21-W
  • AF09ZB-30-10-21-X
  • AF09ZB-30-10-21-Y
  • AF09ZB-30-10-21-Z

More Products Like This

Customers Are Also Buying

We Deliver!

Late West Coast Shipping Hours
Late West Coast Shipping (5PM PST)
Drop-Ship and Blind-Ship Specialists
Expertly Packed Static-Limited
Same-Day Service
In-House Courier
visa credit card logo mastercard credit card logo discover credit card logo american express credit card logo

Customers we work with

3M logo
Kaiser Permanente logo
Safeway Logo
Georgia-Pacific logo
Coca Cola logo
duke energy logo
BART logo
Pepsi logo
LA DWP logo
US Navy logo
Dean Foods logo
ConAgra Brands logo