1SBL177501R1200
Resumen del Producto:
- Extended Product Type: AF16-22-00-12
- Product ID: 1SBL177501R1200
- EAN: 3471523116320
- Minimum Order Quantity: 1 piece
- Customs Tariff Number: 85369085
- Descripción: AF16-22-00-12 48-130V50/60HZ-DC Contactor
- Operate Time: Between Coil De-energization and NC Contact Closing 13...98 ms Between Coil De-energization and NO Contact Opening 11...95 ms Between Coil Energization and NC Contact Opening 38...90 ms Between Coil Energization and NO Contact Closing 40...95 ms
- Connecting Capacity Main Circuit: Flexible with Insulated Ferrule 1x 0.75...4 mm² Flexible with Insulated Ferrule 2x 0.75...2.5 mm² Flexible with Ferrule 1/2x 0.75...6 mm² Rigid 1/2x 1...6 mm²
- Connecting Capacity Control Circuit: Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm² Rigid 1/2x 1 ... 2.5 mm²
- Wire Stripping Length: Control Circuit 10 mm Main Circuit 10 mm
- Degree of Protection: acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20
- Terminal Type: Screw Terminals
- Number of Main Contacts NO: 2
- Climatic Withstand: Category B according to IEC 60947-1 Annex Q
- Maximum Operating Altitude Permissible: 3000 m
- Resistance to Vibrations acc. to IEC 60068-2-6: 5...300 Hz 4 g closed position / 2 g open position
- Resistance to Shock acc. to IEC 60068-2-27: Closed, Shock Direction: B1 25 g Open, Shock Direction: B1 5 g Shock Direction: A 30 g Shock Direction: B2 15 g Shock Direction: C1 25 g Shock Direction: C2 25 g
- RoHS Status: Planned to follow EU Directive 2002/95/EC August 18, 2005 and amendment after 2008 Q1
- Ambient Air Temperature: Close to Contactor for Storage -60...+80 °C Near Contactor for Operation in Free Air -40 ... +70 °C
- General Use Rating UL/CSA: (600 V AC) 30 A
- Tightening Torque UL/CSA: Control Circuit 11 in·lb Main Circuit 13 in·lb
- Instructions and Manuals: 1SBC101027M6801
- ABS Certificate: ABS_15-GE1349500-PDA_90682247
- CB Certificate: CB_SE_70857M1
- CCC Certificate: CCC_2010010304445624
- cUL Certificate: UL_20100802-E319322-3-1
- Data Sheet, Technical Information: 1SBC101422D0201
- Declaration of Conformity - CE: 1SBD250001U1000
- DNV Certificate: DNV-GL_E13871
- EAC Certificate: EAC_RU C-FR ME77 B01010
- GL Certificate: DNV-GL_E13871
- GOST Certificate: GOST_POCCFR.ME77.B07175.pdf
- LR Certificate: LRS_1300087E1
- RINA Certificate: RINA_ELE084013XG
- RMRS Certificate: RMRS_1400682124
- RoHS Information: 1SBD251011E1000
- E-nummer: 3211401
- ETIM 4: EC000066 - Magnet contactor, AC-switching
- ETIM 5: EC000066 - Magnet contactor, AC-switching
- ETIM 6: EC000066 - Power contactor, AC switching
- UNSPSC: 39121529
- Object Classification Code: Q
- Extended Product Type: AF16-22-00-12
- Product ID: 1SBL177501R1200
- EAN: 3471523116320
- Minimum Order Quantity: 1 piece
- Customs Tariff Number: 85369085
- EAN: 3471523116320
- Product Net Depth: 77 mm
- Product Net Height: 86 mm
- Product Net Weight: 0.270 kg
- Product Net Width: 45 mm
- Package Level 1 Width: 87 mm
- Package Level 1 Length: 79 mm
- Package Level 1 Height: 47 mm
- Package Level 1 Gross Weight: 0.27 kg
- Package Level 1 EAN: 3471523116320
- Package Level 2 Units: 54 piece
- Package Level 2 Width: 250 mm
- Package Level 2 Length: 300 mm
- Package Level 2 Height: 315 mm
- Package Level 3 Units: 1296 piece
- Package Level 1 Units: 1 piece
- Number of Main Contacts NC: 2
- Number of Auxiliary Contacts NO: 0
- Number of Auxiliary Contacts NC: 0
- Standards: IEC 60947-1 / 60947-4-1 and EN 60947-1 / 60947-4-1, UL 508, CSA C22.2 N°14
- Rated Operational Voltage: Main Circuit 690 V
- Rated Frequency (f): Main Circuit 50 / 60 Hz
- Conventional Free-air Thermal Current (Ith): acc. to IEC 60947-4-1, Open Contactors q = 40 °C 35 A
- Rated Operational Current AC-1 (Ie): (690 V) 40 °C 30 A (690 V) 60 °C 30 A (690 V) 70 °C 26 A
- Rated Operational Current AC-3 (Ie): (220 / 230 / 240 V) 60 °C 18 A (380 / 400 V) 60 °C 18 A (415 V) 60 °C 18 A (440 V) 60 °C 18 A (500 V) 60 °C 15 A (690 V) 60 °C 10.5 A
- Rated Operational Power AC-3 (Pe): (220 / 230 / 240 V) 4 kW (380 / 400 V) 7.5 kW (400 V) 7.5 kW (415 V) 9 kW (440 V) 9 kW (500 V) 9 kW (690 V) 9 kW
- Rated Short-time Withstand Current (Icw): at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 150 A at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 35 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 60 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 300 A at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 80 A
- Maximum Breaking Capacity: cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 250 A cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 106 A
- Maximum Electrical Switching Frequency: AC-1 600 cycles per hour
- Rated Insulation Voltage (Ui): acc. to UL/CSA 600 V acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V
- Rated Impulse Withstand Voltage (Uimp): 6 kV
- Maximum Mechanical Switching Frequency: 3600 cycles per hour
- Rated Control Circuit Voltage (Uc): 50 Hz 48 ... 130 V 60 Hz 48 ... 130 V DC Operation 48 ... 130 V
Santa Clara Systems se especializa en piezas difíciles de encontrar. Elija de nuestro inventario de exceso y ahorre en 1SBL177501R1200 . Santa Clara Systems tiene 36,195 artículos de ABB.
- Af16 4-Pole Contactors Are Used For Controlling Power Circuits Up To 690 V Ac And 440 V Dc. They Are Mainly Used For Controlling Non-Inductive Or Slightly Inductive Loads (I.E. Resistance Furnaces...). Af... Contactors Include An Electronic Coil Interface Accepting A Wide Control Voltage Uc Min. ... Uc Max. Only Four Coils Cover Control Voltages Between 24...500 V 50/60 Hz Or 20...500 V Dc. Af Contactors Can Manage Large Control Voltage Variations. One Coil Can Be Used For Different Control Voltages Used Worldwide Without Any Coil Change. Af Contactors Have Built-In Surge Protection And Do Not Require Additional Surge Suppressors. The Af... Series 4-Pole Contactors Are Of The Block Type Design. - Main Poles And Auxiliary Contact Blocks: 2 N.O. + 2 N.C. Main Poles
Alternativas
- AF16-22-00-12
- AF16 22 00 12
- AF16220012
Errores Tipográficos Comunes
- 1SBL177501R120O
- 1SBL177501R12O0
- 1SBL177501R12OO
- 1SBL177501R1Z00
- 1SBL177501R1Z0O
- 1SBL177501R1ZO0
- 1SBL177501R1ZOO
- 1SBL177501RI200
- 1SBL177501RI20O
- 1SBL177501RI2O0
- 1SBL177501RI2OO
- 1SBL177501RIZ00
- 1SBL177501RIZ0O
- 1SBL177501RIZO0
- 1SBL177501RIZOO
- 1SBL177501RL200
- 1SBL177501RL20O
- 1SBL177501RL2O0
- 1SBL177501RL2OO
- 1SBL177501RLZ00
- 1SBL177501RLZ0O
- 1SBL177501RLZO0
- 1SBL177501RLZOO
- 1SBL17750IR1200
- 1SBL17750IR120O
Números Adjuntos
- 1SBL177501R1200-A
- 1SBL177501R1200-B
- 1SBL177501R1200-C
- 1SBL177501R1200-D
- 1SBL177501R1200-E
- 1SBL177501R1200-F
- 1SBL177501R1200-G
- 1SBL177501R1200-H
- 1SBL177501R1200-I
- 1SBL177501R1200-J
- 1SBL177501R1200-K
- 1SBL177501R1200-L
- 1SBL177501R1200-M
- 1SBL177501R1200-N
- 1SBL177501R1200-O
- 1SBL177501R1200-P
- 1SBL177501R1200-Q
- 1SBL177501R1200-R
- 1SBL177501R1200-S
- 1SBL177501R1200-T
- 1SBL177501R1200-U
- 1SBL177501R1200-V
- 1SBL177501R1200-W
- 1SBL177501R1200-X
- 1SBL177501R1200-Y
- 1SBL177501R1200-Z
Más Productos Como Este
-
1SBL177501R1100
ABB
-
1SBL177501R1300
ABB
-
1SBL177501R1400
ABB
-
1SBL177001R1101
ABB
Clientes También Están Comprando
-
6ES7 971-1AA00-0AA0 (BATTERY)
Siemens
-
800FM-LF4
Allen Bradley
-
440N-S32038
Allen Bradley
-
LC1D09BD
Telemecanique
Entrega que cumple con sus necesidades

- ✓ Horas Tardes de Envió de la Costa Oeste (5PM Hora del Pacifico)
- ✓ Especialistas en Entrega Directa y Entrega Ciega
- ✓ Empacado por Expertos Estática Reducida
- ✓ Servicio el Mismo Día
- ✓ Mensajero Interno Nacional e Internacional