1SBL351201R8800
Resumen del Producto:
- Extended Product Type: A50-40-00 230-240V 50Hz / 240-260V 60Hz
- Product ID: 1SBL351201R8800
- EAN: 3471522086884
- Minimum Order Quantity: 1 piece
- Customs Tariff Number: 85369085
- Descripción: A50-40-00 230-240V 50Hz / 240-260V 60Hz Contactor
- Coil Consumption: Pull-in at Max. Rated Control Circuit Voltage 50 Hz 180 V·A Pull-in at Max. Rated Control Circuit Voltage 60 Hz 210 V·A Holding at Max. Rated Control Circuit Voltage 60 Hz 18 V·A Holding at Max. Rated Control Circuit Voltage 60 Hz 5.5 W Holding at Max. Rated Control Circuit Voltage 50 Hz 18 V·A Holding at Max. Rated Control Circuit Voltage 50 Hz 5.5 W Average Holding Value 50 / 60 Hz 18 V·A Average Holding Value 50 / 60 Hz 5.5 W Average Pull-in Value 50 Hz 190 V·A Average Pull-in Value 60 Hz 180 V·A
- Operate Time: Between Coil Energization and NO Contact Closing 8 ... 27 ms Between Coil De-energization and NO Contact Opening 4 ... 11 ms
- Connecting Capacity Main Circuit: Flexible with Cable End 6 ... 16 mm² Rigid Cable 6 ... 25 mm²
- Connecting Capacity Auxiliary Circuit: Flexible with Cable End 0.75 ... 2.5 mm² Rigid Cable 1 ... 4 mm²
- Degree of Protection: acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
- Connecting terminals (delivered in open position) Main poles: M 6 (+,-) pozidriv 2 screws with 1x (13 x 10 mm) connector
- Terminal Type: Screw Terminals
- Number of Main Contacts NO: 4
- Climatic Withstand: acc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II
- Maximum Operating Altitude Permissible: 3000 m
- Resistance to Shock acc. to IEC 60068-2-27: Shock Direction: A 20 g Closed, Shock Direction: B1 10 g Open, Shock Direction: B1 5 g Shock Direction: B2 15 g Shock Direction: C1 20 g Shock Direction: C2 20 g
- RoHS Status: Following EU Directive 2002/95/EC August 18, 2005 and amendment
- Ambient Air Temperature: Near Contactor for Operation in Free Air (0.85 ... 1.1 Uc) -40 ... +55 °C Near Contactor for Operation in Free Air (Uc) -40 ... +70 °C Close to Contactor for Storage -60 ... +80 °C
- Instructions and Manuals: FPTC407701P0003
- BV Certificate: BV_2634H07559D0
- CCC Certificate: CCC_2002010304016447
- CSA Certificate: CSA_1033838_LR056745
- cUL Certificate: UL_071301E39231
- Data Sheet, Technical Information: 1SBC100122C0202_Ch02
- Declaration of Conformity - CE: 1SBD250802U1000
- DNV Certificate: DNV-GL_TAE00000TX
- EAC Certificate: EAC_RU C-FR ME77 B01010
- GL Certificate: DNV-GL_TAE00000TX
- GOST Certificate: GOST_POCCFRME77B07175
- LR Certificate: LRS_9830011E4
- RINA Certificate: RINA_ELE400503CS1
- RMRS Certificate: RMRS_0507015250
- RoHS Information: 1SBD350054R1000
- UL Certificate: UL_071301E39231
- E-nummer: 3228075
- ETIM 4: EC000066 - Magnet contactor, AC-switching
- ETIM 5: EC000066 - Magnet contactor, AC-switching
- ETIM 6: EC000066 - Power contactor, AC switching
- UNSPSC: 39121529
- Object Classification Code: Q
- Extended Product Type: A50-40-00 230-240V 50Hz / 240-260V 60Hz
- Product ID: 1SBL351201R8800
- EAN: 3471522086884
- Minimum Order Quantity: 1 piece
- Customs Tariff Number: 85369085
- EAN: 3471522086884
- Product Net Depth: 119.5 mm
- Product Net Height: 110 mm
- Product Net Weight: 1.390 kg
- Product Net Width: 92 mm
- Package Level 1 Width: 142 mm
- Package Level 1 Length: 190 mm
- Package Level 1 Height: 136 mm
- Package Level 1 Gross Weight: 1.39 kg
- Package Level 1 EAN: 3471522086884
- Package Level 2 Units: 63 piece
- Package Level 1 Units: 1 piece
- Number of Main Contacts NC: 0
- Number of Auxiliary Contacts NO: 0
- Number of Auxiliary Contacts NC: 0
- Standards: Devices complying with international standards IEC 947-1 / 947-4-1, and European standards EN 60 947-1 / 60 947-4-1. Electromagnetic compatibility (EMC) acc. to amendment A11 to IEC 947-1; EN 60 947-1 and amendment 2 to IEC 947-4-1
- Rated Operational Voltage: Main Circuit 1000 V
- Conventional Free-air Thermal Current (Ith): acc. to IEC 60947-4-1, Open Contactors q = 40 °C 100 A
- Rated Operational Current AC-1 (Ie): (690 V) 40 °C 100 A (690 V) 55 °C 85 A (690 V) 70 °C 70 A
- Rated Operational Current AC-3 (Ie): (1000 V) 55 °C 23 A (220 / 230 / 240 V) 55 °C 53 A (380 / 400 V) 55 °C 50 A (415 V) 55 °C 50 A (440 V) 55 °C 45 A (500 V) 55 °C 45 A (690 V) 55 °C 35 A
- Rated Breaking Capacity AC-3 acc. to IEC 60947-4-1: 8 x Ie AC-3
- Rated Making Capacity AC-3 acc. to IEC 60947-4-1: 10 x Ie AC-3
- Short-Circuit Protective Devices: gG Type Fuses 100 A
- Rated Short-time Withstand Current (Icw): at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 650 A at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 110 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 250 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1000 A at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 370 A
- Maximum Breaking Capacity: cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1300 A cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 630 A
- Maximum Electrical Switching Frequency: AC-1 600 cycles per hour AC-2 / AC-4 150 cycles per hour AC-3 600 cycles per hour
- Rated Insulation Voltage (Ui): acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V acc. to UL/CSA 600 V
- Rated Impulse Withstand Voltage (Uimp): 8 kV
- Mechanical Durability: 10 million
- Maximum Mechanical Switching Frequency: 3600 cycles per hour
- Coil Operating Limits: (acc. to IEC 60947-4-1) 0.85 ... 1.1 x Uc (at ? ? 55 °C) °C
- Rated Control Circuit Voltage (Uc): 50 Hz 230 240 V 60 Hz 240 260 V
Santa Clara Systems se especializa en piezas difíciles de encontrar. Elija de nuestro inventario de exceso y ahorre en 1SBL351201R8800 . Santa Clara Systems tiene 36,195 artículos de ABB.
- A50 4-Pole Contactors Are Mainly Used For Controlling Non-Inductive Or Slightly Inductive Loads (I.E. Resistance Furnaces...) And Generally For Controlling Power Circuits Up To 690 V Ac And 440 V Dc. The Contactors Can Also Be Used For Many Other Applications Such Lighting... The A... Series 4-Pole Contactors Are Of The Block Type Design. - Main Poles And Auxiliary Contact Blocks: 4 N.O. Main Poles
Alternativas
- A50-40-00-88
- A50 40 00 88
- A50400088
Errores Tipográficos Comunes
- 1SBL351201R880O
- 1SBL351201R88O0
- 1SBL351201R88OO
- 1SBL351201R8B00
- 1SBL351201R8B0O
- 1SBL351201R8BO0
- 1SBL351201R8BOO
- 1SBL351201RB800
- 1SBL351201RB80O
- 1SBL351201RB8O0
- 1SBL351201RB8OO
- 1SBL351201RBB00
- 1SBL351201RBB0O
- 1SBL351201RBBO0
- 1SBL351201RBBOO
- 1SBL35120IR8800
- 1SBL35120IR880O
- 1SBL35120IR88O0
- 1SBL35120IR88OO
- 1SBL35120IR8B00
- 1SBL35120IR8B0O
- 1SBL35120IR8BO0
- 1SBL35120IR8BOO
- 1SBL35120IRB800
- 1SBL35120IRB80O
Números Adjuntos
- 1SBL351201R8800-A
- 1SBL351201R8800-B
- 1SBL351201R8800-C
- 1SBL351201R8800-D
- 1SBL351201R8800-E
- 1SBL351201R8800-F
- 1SBL351201R8800-G
- 1SBL351201R8800-H
- 1SBL351201R8800-I
- 1SBL351201R8800-J
- 1SBL351201R8800-K
- 1SBL351201R8800-L
- 1SBL351201R8800-M
- 1SBL351201R8800-N
- 1SBL351201R8800-O
- 1SBL351201R8800-P
- 1SBL351201R8800-Q
- 1SBL351201R8800-R
- 1SBL351201R8800-S
- 1SBL351201R8800-T
- 1SBL351201R8800-U
- 1SBL351201R8800-V
- 1SBL351201R8800-W
- 1SBL351201R8800-X
- 1SBL351201R8800-Y
- 1SBL351201R8800-Z
Más Productos Como Este
-
1SBL351201R8000
ABB
-
1SBL351201R8100
ABB
-
1SBL351201R8300
ABB
-
1SBL351201R8500
ABB
Clientes También Están Comprando
-
IC697 ACC 701 (BATTERY)
General Electric
-
800F-X10
Allen Bradley
-
194L-HE8N-175
Allen Bradley
-
3RH1 921-1HA22
Siemens
Entrega que cumple con sus necesidades

- ✓ Horas Tardes de Envió de la Costa Oeste (5PM Hora del Pacifico)
- ✓ Especialistas en Entrega Directa y Entrega Ciega
- ✓ Empacado por Expertos Estática Reducida
- ✓ Servicio el Mismo Día
- ✓ Mensajero Interno Nacional e Internacional



