1SBL407001R1222
Resumen del Producto:
- Extended Product Type: AF96-30-22-12
- Product ID: 1SBL407001R1222
- EAN: 3471523133426
- Minimum Order Quantity: 1 piece
- Customs Tariff Number: 85369085
- Descripción: AF96-30-22-12 48-130V50/60HZ-DC Contactor
- Rated Control Circuit Voltage (Uc): 50 Hz 48 ... 130 V 60 Hz 48 ... 130 V DC Operation 48 ... 130 V
- Operate Time: Between Coil De-energization and NC Contact Closing 19 ... 105 ms Between Coil De-energization and NO Contact Opening 17 ... 100 ms Between Coil Energization and NC Contact Opening 38 ... 95 ms Between Coil Energization and NO Contact Closing 42 ... 100 ms
- Connecting Capacity Main Circuit: Flexible with Insulated Ferrule 1/2x 6...50 mm² Flexible with Ferrule 1/2x 6...50 mm² Rigid 1x 6...70 mm² Rigid 2x 6...50 mm²
- Connecting Capacity Auxiliary Circuit: Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm² Rigid 1/2x 1...2.5 mm²
- Connecting Capacity Control Circuit: Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm² Rigid 1/2x 1 ... 2.5 mm²
- Wire Stripping Length: Main Circuit 17 mm
- Degree of Protection: acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20 acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
- Terminal Type: Screw Terminals
- Number of Main Contacts NO: 3
- Climatic Withstand: Category B according to IEC 60947-1 Annex Q
- Maximum Operating Altitude Permissible: 3000 m
- Resistance to Vibrations acc. to IEC 60068-2-6: 5 ... 300 Hz 3 g closed position / 3 g open position
- Resistance to Shock acc. to IEC 60068-2-27: Closed, Shock Direction: A 25 g Closed, Shock Direction: B1 25 g Closed, Shock Direction: B2 15 g Closed, Shock Direction: C1 25 g Closed, Shock Direction: C2 25 g Open, Shock Direction: B1 5 g
- Ambient Air Temperature: Close to Contactor for Storage -60...+80 °C Close to Contactor Fitted with Thermal O/L Relay -25 ... +60 °C Close to Contactor without Thermal O/L Relay -40 ... +70 °C
- Horsepower Rating UL/CSA: (120 V AC) Single Phase 7-1/2 Hp (240 V AC) Single Phase 20 Hp (200 ... 208 V AC) Three Phase 30 Hp (220 ... 240 V AC) Three Phase 30 Hp (440 ... 480 V AC) Three Phase 60 Hp (550 ... 600 V AC) Three Phase 75 Hp
- Tightening Torque UL/CSA: Auxiliary Circuit 11 in·lb Control Circuit 11 in·lb Main Circuit 53 in·lb
- Instructions and Manuals: 1SBC101036M6801
- ABS Certificate: ABS_15-GE1349500-PDA_90682247
- BV Certificate: BV_2634H36994A
- CB Certificate: CB_SE-77417M1
- CCC Certificate: CCC_2013010304646569
- cUL Certificate: UL_20130926-E312527_14_1
- Data Sheet, Technical Information: 1SBC100173C0201
- Declaration of Conformity - CE: 1SBD250000U1000
- DNV Certificate: DNV-GL_E13871
- EAC Certificate: EAC_RU C-FR ME77 B01010
- GL Certificate: DNV-GL_E13871
- LR Certificate: LRS_1300087E1
- RINA Certificate: RINA_ELE084013XG
- RMRS Certificate: RMRS_1400682124
- RoHS Information: 1SBD251021E1000
- ETIM 4: EC000066 - Magnet contactor, AC-switching
- ETIM 5: EC000066 - Magnet contactor, AC-switching
- ETIM 6: EC000066 - Power contactor, AC switching
- UNSPSC: 39121529
- Object Classification Code: Q
- Extended Product Type: AF96-30-22-12
- Product ID: 1SBL407001R1222
- EAN: 3471523133426
- Minimum Order Quantity: 1 piece
- Customs Tariff Number: 85369085
- EAN: 3471523133426
- Product Net Depth: 149 mm
- Product Net Height: 125.5 mm
- Product Net Weight: 1.270 kg
- Product Net Width: 70 mm
- Package Level 1 Width: 180 mm
- Package Level 1 Length: 150 mm
- Package Level 1 Height: 102 mm
- Package Level 1 Gross Weight: 1.41 kg
- Package Level 1 EAN: 3471523133426
- Package Level 2 Units: 6 piece
- Package Level 2 Width: 250 mm
- Package Level 2 Length: 300 mm
- Package Level 2 Height: 300 mm
- Package Level 3 Units: 144 piece
- Package Level 1 Units: 1 piece
- Number of Main Contacts NC: 0
- Number of Auxiliary Contacts NO: 2
- Number of Auxiliary Contacts NC: 2
- Rated Operational Voltage: Auxiliary Circuit 690 V Main Circuit 690 V
- Rated Frequency (f): Auxiliary Circuit 50 / 60 Hz Main Circuit 50 / 60 Hz
- Conventional Free-air Thermal Current (Ith): acc. to IEC 60947-4-1, Open Contactors q = 40 °C 130 A acc. to IEC 60947-5-1, q = 40 °C 16 A
- Rated Operational Current AC-1 (Ie): (690 V) 40 °C 130 A (690 V) 60 °C 105 A (690 V) 70 °C 90 A
- Rated Operational Current AC-3 (Ie): (220 / 230 / 240 V) 60 °C 96 A (380 / 400 V) 60 °C 96 A (415 V) 60 °C 96 A (440 V) 60 °C 96 A (500 V) 60 °C 80 A (690 V) 60 °C 57 A (1000 V) 60 °C 30 A
- Rated Operational Power AC-3 (Pe): (220 / 230 / 240 V) 25 kW (380 / 400 V) 45 kW (400 V) 45 kW (415 V) 55 kW (440 V) 55 kW (500 V) 55 kW (690 V) 55 kW
- Rated Operational Current AC-15 (Ie): (220 / 240 V) 4 A (24 / 127 V) 6 A (400 / 440 V) 3 A (500 V) 2 A (690 V) 2 A
- Rated Short-time Withstand Current (Icw): at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 780 A at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 140 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 300 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1200 A at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 450 A for 0.1 s 140 A for 1 s 100 A
- Maximum Breaking Capacity: cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1150 A cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 750 A
- Maximum Electrical Switching Frequency: AC-1 600 cycles per hour AC-15 1200 cycles per hour AC-2 / AC-4 150 cycles per hour AC-3 1200 cycles per hour DC-13 900 cycles per hour
- Rated Operational Current DC-13 (Ie): (110 V) 0.55 A / 60 W (125 V) 0.55 A / 69 W (220 V) 0.27 A / 60 W (24 V) 6 A / 144 W (250 V) 0.27 A / 68 W (400 V) 0.15 A / 60 W (48 V) 2.8 A / 134 W (500 V) 0.13 A / 65 W (600 V) 0.1 A / 60 W (72 V) 1 A / 72 W
- Rated Insulation Voltage (Ui): acc. to UL/CSA 600 V acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V
- Rated Impulse Withstand Voltage (Uimp): 8 kV
- Maximum Mechanical Switching Frequency: 3600 cycles per hour
Santa Clara Systems se especializa en piezas difíciles de encontrar. Elija de nuestro inventario de exceso y ahorre en 1SBL407001R1222 . Santa Clara Systems tiene 36,195 artículos de ABB.
- Side-Mounted Add-On Auxiliary Contact Blocks (Mechanically-Linked Auxiliary Contacts Compliant With Annex L Of Iec 60947-5-1 Including The &Quot;Mechanically Linked&Quot; Symbol On The Contactor Side. N.C. Mirror Contacts Compliant With Annex F Of Iec 60947-4-1) - Control Circuit: Ac Or Dc Operated - Accessories: A Wide Range Of Accessories Is Available. Note: 2-Stack Contactors Available In Some Countries: Please Consult Your Abb Representative.
Alternativas
- AF96-30-22-12
- AF96 30 22 12
- AF96302212
Errores Tipográficos Comunes
- 1SBL407001R122Z
- 1SBL407001R12Z2
- 1SBL407001R12ZZ
- 1SBL407001R1Z22
- 1SBL407001R1Z2Z
- 1SBL407001R1ZZ2
- 1SBL407001R1ZZZ
- 1SBL407001RI222
- 1SBL407001RI22Z
- 1SBL407001RI2Z2
- 1SBL407001RI2ZZ
- 1SBL407001RIZ22
- 1SBL407001RIZ2Z
- 1SBL407001RIZZ2
- 1SBL407001RIZZZ
- 1SBL407001RL222
- 1SBL407001RL22Z
- 1SBL407001RL2Z2
- 1SBL407001RL2ZZ
- 1SBL407001RLZ22
- 1SBL407001RLZ2Z
- 1SBL407001RLZZ2
- 1SBL407001RLZZZ
- 1SBL40700IR1222
- 1SBL40700IR122Z
Números Adjuntos
- 1SBL407001R1222-A
- 1SBL407001R1222-B
- 1SBL407001R1222-C
- 1SBL407001R1222-D
- 1SBL407001R1222-E
- 1SBL407001R1222-F
- 1SBL407001R1222-G
- 1SBL407001R1222-H
- 1SBL407001R1222-I
- 1SBL407001R1222-J
- 1SBL407001R1222-K
- 1SBL407001R1222-L
- 1SBL407001R1222-M
- 1SBL407001R1222-N
- 1SBL407001R1222-O
- 1SBL407001R1222-P
- 1SBL407001R1222-Q
- 1SBL407001R1222-R
- 1SBL407001R1222-S
- 1SBL407001R1222-T
- 1SBL407001R1222-U
- 1SBL407001R1222-V
- 1SBL407001R1222-W
- 1SBL407001R1222-X
- 1SBL407001R1222-Y
- 1SBL407001R1222-Z
Más Productos Como Este
-
1SBL407001R1200
ABB
-
1SBL407001R1211
ABB
-
1SBL407001R1100
ABB
-
1SBL407001R1111
ABB
Clientes También Están Comprando
-
440E-L13042
Allen Bradley
-
LUB 32
Telemecanique
-
X-181170
Allen Bradley
-
990 XCP 980 00 (BATTERY)
Modicon
Entrega que cumple con sus necesidades

- ✓ Horas Tardes de Envió de la Costa Oeste (5PM Hora del Pacifico)
- ✓ Especialistas en Entrega Directa y Entrega Ciega
- ✓ Empacado por Expertos Estática Reducida
- ✓ Servicio el Mismo Día