• ABB 1SFL597001R6922 AF460-30-22 48-130V 50/60Hz / 48-130V DC Contactor Product Image
  • Abb 1SFL597001R6922 Barcode

1SFL597001R6922

Resumen del Producto:

  • Extended Product Type: AF460-30-22 48-130V 50/60Hz / 48-130V DC
  • Product ID: 1SFL597001R6922
  • EAN: 7320500217924
  • Minimum Order Quantity: 1 piece
  • Customs Tariff Number: 85364900
Deje Que Lo Busquemos
           o           
  • Descripción: AF460-30-22 48-130V 50/60Hz / 48-130V DC Contactor
  • Mechanical Durability: 5 million
  • Maximum Mechanical Switching Frequency: 300 cycles per hour
  • Coil Operating Limits: (acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at ? ? 70 °C) °C
  • Rated Control Circuit Voltage (Uc): 60 Hz 48 130 V 50 Hz 48 130 V DC Operation 48 130 V
  • Coil Consumption: Pull-in at Max. Rated Control Circuit Voltage 60 Hz 1215 V·A Holding at Max. Rated Control Circuit Voltage DC 5 V·A Holding at Max. Rated Control Circuit Voltage 50 Hz 12 V·A Pull-in at Max. Rated Control Circuit Voltage DC 1150 V·A Pull-in at Max. Rated Control Circuit Voltage 50 Hz 1215 V·A Holding at Max. Rated Control Circuit Voltage 60 Hz 12 V·A
  • Operate Time: Between Coil Energization and NO Contact Closing 50 ... 120 ms Between Coil De-energization and NO Contact Opening 48 ... 58 ms Between Coil De-energization and NC Contact Closing 45 ... 55 ms Between Coil Energization and NC Contact Opening 45 ... 115 ms
  • Connecting Capacity Main Circuit: Rigid Al-Cable 2x240 mm² Bar 47 mm Rigid Cu-Cable 240 mm²
  • Connecting Capacity Auxiliary Circuit: Solid 2x14 mm² Flexible with Insulated Ferrule 2x0.752.5 mm² Stranded 2x14 mm² Flexible 1x0.752.5 mm² Flexible with Ferrule 2x0.752.5 mm²
  • Degree of Protection: acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
  • Terminal Type: Main Circuit: Bars
  • Number of Main Contacts NO: 3
  • Maximum Operating Altitude Permissible: 3000 m
  • Resistance to Shock acc. to IEC 60068-2-27: Shock Direction: A 5 g Shock Direction: C2 5 g Shock Direction: B2 5 g Shock Direction: C1 5 g Shock Direction: B1 5 g
  • RoHS Status: Following EU Directive 2002/95/EC August 18, 2005 and amendment
  • Ambient Air Temperature: Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25+50 °C Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40+70 °C Close to Contactor for Storage -40+70 °C
  • General Use Rating UL/CSA: (600 V AC) 650 A
  • Horsepower Rating UL/CSA: (208 V AC) Three Phase 150 Hp (440 ... 480 V AC) Three Phase 400 Hp (550 ... 600 V AC) Three Phase 500 Hp (220 ... 240 V AC) Three Phase 200 Hp (200 V AC) Three Phase 150 Hp
  • Maximum Operating Voltage UL/CSA: Main Circuit 600 V
  • Instructions and Manuals: 1SFC380023-en
  • BV Certificate: 11727/C0 BV
  • CB Certificate: SE-69485
  • CCC Certificate: CQC_2007010304256683
  • CSA Certificate: 306711
  • Data Sheet, Technical Information: 1SBC100122C0202
  • Declaration of Conformity - CE: 1SFA1-65
  • DNV Certificate: DNV_E-10966
  • GL Certificate: GL_42988-02HH
  • LOVAG Certificate: FI102
  • LR Certificate: LR_13_20009
  • RINA Certificate: ELE060313XG/002
  • RoHS Information: 1SFC101055D0202
  • ETIM 4: EC000066 - Magnet contactor, AC-switching
  • ETIM 5: EC000066 - Magnet contactor, AC-switching
  • UNSPSC: 39121529
  • Object Classification Code: Q
  • Extended Product Type: AF460-30-22 48-130V 50/60Hz / 48-130V DC
  • Product ID: 1SFL597001R6922
  • EAN: 7320500217924
  • Minimum Order Quantity: 1 piece
  • Customs Tariff Number: 85364900
  • EAN: 7320500217924
  • Product Net Depth: 216.0 mm
  • Product Net Height: 278.0 mm
  • Product Net Weight: 12.000 kg
  • Product Net Width: 186.0 mm
  • Package Level 1 Width: 260 mm
  • Package Level 1 Length: 250 mm
  • Package Level 1 Height: 350 mm
  • Package Level 1 Gross Weight: 12 kg
  • Package Level 1 EAN: 7320500217924
  • Package Level 1 Units: 1 piece
  • Number of Main Contacts NC: 0
  • Number of Auxiliary Contacts NO: 2
  • Number of Auxiliary Contacts NC: 2
  • Rated Operational Voltage: Main Circuit 1000 V
  • Rated Frequency (f): Main Circuit 50/60 Hz
  • Conventional Free-air Thermal Current (Ith): acc. to IEC 60947-4-1, Open Contactors q = 40 °C 700 A
  • Rated Operational Current AC-1 (Ie): (690 V) 55 °C 600 A (690 V) 40 °C 700 A (1000 V) 40 °C 700 A (1000 V) 55 °C 600 A (690 V) 70 °C 480 A (1000 V) 70 °C 480 A
  • Rated Operational Current AC-3 (Ie): (1000 V) 55 °C 200 A (690 V) 55 °C 400 A (415 V) 55 °C 460 A (220 / 230 / 240 V) 55 °C 460 A (440 V) 55 °C 460 A (380 / 400 V) 55 °C 460 A (500 V) 55 °C 460 A
  • Rated Operational Power AC-3 (Pe): (500 V) 315 kW (220 / 230 / 240 V) 132 kW (690 V) 355 kW (380 / 400 V) 250 kW (440 V) 250 kW (415 V) 250 kW
  • Rated Breaking Capacity AC-3 acc. to IEC 60947-4-1: 8 x Ie AC-3
  • Rated Making Capacity AC-3 acc. to IEC 60947-4-1: 10 x Ie AC-3
  • Short-Circuit Protective Devices: gG Type Fuses 800 A
  • Rated Short-time Withstand Current (Icw): at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 3100 A at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 840 A at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 4400 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 4600 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 2500 A
  • Maximum Breaking Capacity: cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 5000 A cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 4500 A
  • Maximum Electrical Switching Frequency: AC-3 300 cycles per hour AC-1 300 cycles per hour AC-2 / AC-4 60 cycles per hour
  • Rated Operational Current DC-1 (Ie): (600 V) 3 Poles in Series, 40 °C 700 A (110 V) 1-Pole, 40 °C 700 A (110 V) 2 Poles in Series, 40 °C 700 A (220 V) 3 Poles in Series, 40 °C 700 A
  • Rated Operational Current DC-3 (Ie): (600 V) 3 Poles in Series, 40 °C 700 A (110 V) 1-Pole, 40 °C 700 A (110 V) 2 Poles in Series, 40 °C 700 A (220 V) 3 Poles in Series, 40 °C 700 A
  • Rated Operational Current DC-5 (Ie): (600 V) 3 Poles in Series, 40 °C 700 A (110 V) 1-Pole, 40 °C 700 A (110 V) 2 Poles in Series, 40 °C 700 A (220 V) 3 Poles in Series, 40 °C 700 A
  • Rated Insulation Voltage (Ui): acc. to UL/CSA 600 V acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V
  • Rated Impulse Withstand Voltage (Uimp): Main Circuit 8 kV
Santa Clara Systems se especializa en piezas difíciles de encontrar. Elija de nuestro inventario de exceso y ahorre en 1SFL597001R6922 . Santa Clara Systems tiene 35,881 artículos de ABB.
  • Ac/Dc
  • A 3-Phase Contactor Suitable For Various Applications Such As Motor Starting
  • Isolation
  • By-Pass And Distribution Application Up To Max 1000 V. Operated With Wide Control Voltage Range 48-130 V
  • Alternativas

    • AF460-30-22-69
    • AF460 30 22 69
    • AF460302269

    Errores Tipográficos Comunes

    • 1SFL597001R692Z
    • 1SFL597001R69Z2
    • 1SFL597001R69ZZ
    • 1SFL597001RG922
    • 1SFL597001RG92Z
    • 1SFL597001RG9Z2
    • 1SFL597001RG9ZZ
    • 1SFL59700IR6922
    • 1SFL59700IR692Z
    • 1SFL59700IR69Z2
    • 1SFL59700IR69ZZ
    • 1SFL59700IRG922
    • 1SFL59700IRG92Z
    • 1SFL59700IRG9Z2
    • 1SFL59700IRG9ZZ
    • 1SFL59700LR6922
    • 1SFL59700LR692Z
    • 1SFL59700LR69Z2
    • 1SFL59700LR69ZZ
    • 1SFL59700LRG922
    • 1SFL59700LRG92Z
    • 1SFL59700LRG9Z2
    • 1SFL59700LRG9ZZ
    • 1SFL5970O1R6922
    • 1SFL5970O1R692Z

    Números Adjuntos

    • 1SFL597001R6922-A
    • 1SFL597001R6922-B
    • 1SFL597001R6922-C
    • 1SFL597001R6922-D
    • 1SFL597001R6922-E
    • 1SFL597001R6922-F
    • 1SFL597001R6922-G
    • 1SFL597001R6922-H
    • 1SFL597001R6922-I
    • 1SFL597001R6922-J
    • 1SFL597001R6922-K
    • 1SFL597001R6922-L
    • 1SFL597001R6922-M
    • 1SFL597001R6922-N
    • 1SFL597001R6922-O
    • 1SFL597001R6922-P
    • 1SFL597001R6922-Q
    • 1SFL597001R6922-R
    • 1SFL597001R6922-S
    • 1SFL597001R6922-T
    • 1SFL597001R6922-U
    • 1SFL597001R6922-V
    • 1SFL597001R6922-W
    • 1SFL597001R6922-X
    • 1SFL597001R6922-Y
    • 1SFL597001R6922-Z

    Clientes También Están Comprando

    Entrega que cumple con sus necesidades

    Late West Coast Shipping Hours
    Horas Tardes de Envió de la Costa Oeste (5PM Hora del Pacifico)
    Especialistas en Entrega Directa y Entrega Ciega
    Empacado por Expertos Estática Reducida
    Servicio el Mismo Día
    Mensajero Interno Nacional e Internacional
    visa credit card logo mastercard credit card logo discover credit card logo american express credit card logo