• ABB 2CCP844001R1139 S804PV-S13-R High Performance Circuit Breaker Product Image
  • Abb 2CCP844001R1139 Barcode

2CCP844001R1139

Resumen del Producto:

  • Extended Product Type: S804PV-S13
  • Product ID: 2CCP844001R1139
  • EAN: 7612271211141
  • Minimum Order Quantity: 1 piece
  • Customs Tariff Number: 85362020
Deje Que Lo Busquemos
           o           
  • Descripción: S804PV-S13-R High Performance Circuit Breaker
  • Rated Insulation Voltage (Ui): 1500 V DC
  • Rated Ultimate Short-Circuit Breaking Capacity (Icu): (1200 V DC) 5 kA
  • Rated Service Short-Circuit Breaking Capacity (Ics): (1200 V DC) 5 kA
  • Overvoltage Category: III
  • Pollution Degree: 2
  • Rated Impulse Withstand Voltage (Uimp): 8 kV
  • Housing Material: Insulation group I, RAL 7035
  • Contact Position Indication: ON / OFF / TRIP
  • Degree of Protection: acc. to IEC 60529 IP20
  • Remarks: Connection from top and bottom
    Connecting with CU only
    IP40 in enclosure with cover
    Cage terminal with captive screw
  • Terminal Type: Screw Terminals
  • Connecting Capacity: Flexible 1 ... 50 mm² Flexible Stranded
    1 70 mm²
  • Tightening Torque: 3.5 N·m
  • Recommended Screw Driver: Pozidriv 2
  • Mounting on DIN Rail: TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
  • Mounting Position: Any
  • Standards: IEC/EN 60947-2
  • Instructions and Manuals: 2CCC413016M0031
  • Data Sheet, Technical Information: 2CCC413003C0203
  • Declaration of Conformity - CE: 2CCC413035D0601
  • RoHS Information: 2CCC413008D0204
  • ETIM 4: EC000042 - Miniature circuit breaker (MCB)
  • ETIM 5: EC000042 - Miniature circuit breaker (MCB)
  • ETIM 6: EC000042 - Miniature circuit breaker (MCB)
  • Object Classification Code: F
  • Extended Product Type: S804PV-S13
  • Product ID: 2CCP844001R1139
  • EAN: 7612271211141
  • Minimum Order Quantity: 1 piece
  • Customs Tariff Number: 85362020
  • EAN: 7612271211141
  • Product Net Depth: 82.5 mm
  • Product Net Height: 95 mm
  • Product Net Weight: 0.98 kg
  • Product Net Width: 106 mm
  • Package Level 1 Width: 105 mm
  • Package Level 1 Length: 111 mm
  • Package Level 1 Height: 99 mm
  • Package Level 1 Gross Weight: 1.01 kg
  • Package Level 1 EAN: 7612271211141
  • Package Level 1 Units: 1 piece
  • Ambient Air Temperature: Operation -25 ... +60 °C Storage -40 ... +70 °C
  • Resistance to Shock acc. to IEC 60068-2-27: 5 g 30 ms
  • Resistance to Vibrations acc. to IEC 60068-2-6: 2 - 13.2 Hz / 1mm
    13.2 - 100Hz / 0.7g
    with load 100% x Ie
  • Environmental Conditions: Damp Heat Cyclic acc. to IEC 60068-2-30 12+12 cycle Damp Heat Cyclic acc. to IEC 60068-2-30 55°C @ 90-96% Damp Heat Cyclic acc. to IEC 60068-2-30 25°C @ 90-100% Dry Heat Test B acc. to IEC 60068-2-2 16 hour @ 55 °C Dry Heat Test B acc. to IEC 60068-2-2 2 hour @ 70 °C
  • RoHS Status: Following EU Directive 2002/95/EC August 18, 2005 and amendment
  • Number of Poles: 4
  • Tripping Characteristic: B
  • Rated Current (In): 13
  • Rated Operational Voltage: 1200 V DC
  • Power Loss: at Rated Operating Conditions per Pole 2 W
Santa Clara Systems se especializa en piezas difíciles de encontrar. Elija de nuestro inventario de exceso y ahorre en 2CCP844001R1139 . Santa Clara Systems tiene 35,881 artículos de ABB.
  • Therefore It Can Be Used Worldwide. The Extensive Range Of Accessory Makes The Use Of S804Pv-S13 More Comfortable. Due To The Fast Arc Extinction Of S804Pv-S13 Your Application Will Be Secured.
  • The S804Pv-S13 Is A 2-Pole High Performance Circuit Breaker For Photovoltaics (Dc) With B-Characteristic
  • With Cage Terminal And A Rated Current Of 13 A. It Is A Current Limiting Device With A Maximum Breaking Capacity Of 5Ka At 1200V. It Can Be Used For Voltages Up To 1200V Dc. It Has Two Different Tripping Mechanisms
  • The Thermal Tripping Mechanism For Overload Protection And The Electromechanic Tripping Mechanism For Short Circuit Protection. The S804Pv-S13 Complies With Iec/En 60947-2 And Allows The Use For Industrial Applications. It Has Numerous Of Approvals
  • Alternativas

    • S804PV-S13
    • S804PV S13
    • S804PVS13

    Errores Tipográficos Comunes

    • 2CCP844001R1I39
    • 2CCP844001R1L39
    • 2CCP844001RI139
    • 2CCP844001RII39
    • 2CCP844001RIL39
    • 2CCP844001RL139
    • 2CCP844001RLI39
    • 2CCP844001RLL39
    • 2CCP84400IR1139
    • 2CCP84400IR1I39
    • 2CCP84400IR1L39
    • 2CCP84400IRI139
    • 2CCP84400IRII39
    • 2CCP84400IRIL39
    • 2CCP84400IRL139
    • 2CCP84400IRLI39
    • 2CCP84400IRLL39
    • 2CCP84400LR1139
    • 2CCP84400LR1I39
    • 2CCP84400LR1L39
    • 2CCP84400LRI139
    • 2CCP84400LRII39
    • 2CCP84400LRIL39
    • 2CCP84400LRL139
    • 2CCP84400LRLI39

    Números Adjuntos

    • 2CCP844001R1139-A
    • 2CCP844001R1139-B
    • 2CCP844001R1139-C
    • 2CCP844001R1139-D
    • 2CCP844001R1139-E
    • 2CCP844001R1139-F
    • 2CCP844001R1139-G
    • 2CCP844001R1139-H
    • 2CCP844001R1139-I
    • 2CCP844001R1139-J
    • 2CCP844001R1139-K
    • 2CCP844001R1139-L
    • 2CCP844001R1139-M
    • 2CCP844001R1139-N
    • 2CCP844001R1139-O
    • 2CCP844001R1139-P
    • 2CCP844001R1139-Q
    • 2CCP844001R1139-R
    • 2CCP844001R1139-S
    • 2CCP844001R1139-T
    • 2CCP844001R1139-U
    • 2CCP844001R1139-V
    • 2CCP844001R1139-W
    • 2CCP844001R1139-X
    • 2CCP844001R1139-Y
    • 2CCP844001R1139-Z

    Clientes También Están Comprando

    Entrega que cumple con sus necesidades

    Late West Coast Shipping Hours
    Horas Tardes de Envió de la Costa Oeste (5PM Hora del Pacifico)
    Especialistas en Entrega Directa y Entrega Ciega
    Empacado por Expertos Estática Reducida
    Servicio el Mismo Día
    Mensajero Interno Nacional e Internacional
    visa credit card logo mastercard credit card logo discover credit card logo american express credit card logo