2CCS861001R0407
Resumen del Producto:
- Extended Product Type: S801S-K8
- Product ID: 2CCS861001R0407
- EAN: 7612271411442
- Minimum Order Quantity: 1 piece
- Customs Tariff Number: 85362020
- Descripción: S801S-K8 High Performance Circuit Breaker
- Rated Ultimate Short-Circuit Breaking Capacity (Icu): (240 / 415 V AC) 50 kA (254 / 440 V AC) 30 kA (400 / 690 V AC) 6 kA (125 V DC) 30 kA
- Rated Service Short-Circuit Breaking Capacity (Ics): (240 / 415 V AC) 40 kA (254 / 440 V AC) 22.5 kA (400 / 690 V AC) 4 kA (125 V DC) 30 kA
- Overvoltage Category: IV
- Pollution Degree: 3
- Rated Impulse Withstand Voltage (Uimp): 8 kV
- Housing Material: Insulation group I, RAL 7035
- Contact Position Indication: ON / OFF / TRIP
- Degree of Protection: acc. to IEC 60529 IP20
- Remarks: Connection from top and bottom
Connecting with CU only
IP40 in enclosure with cover
Cage terminal with captive screw - Electrical Endurance: 10000 cycle
- Mechanical Endurance: 10000 cycle
- Terminal Type: Screw Terminals
- Connecting Capacity: Stranded 1 ... 50 mm² Flexible 1 70 mm²
- Tightening Torque: 3.5 N·m 31 in·lb
- Recommended Screw Driver: Pozidriv 2
- Mounting on DIN Rail: TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
- Mounting Position: Any
- Standards: IEC/EN 60947-2 IEC/EN 60898-1
- Instructions and Manuals: 2CCC413016M0004
- Data Sheet, Technical Information: 2CCC413003C0203
- Declaration of Conformity - CE: 2CCC413016D060
- RoHS Information: 2CCC413008D0204
- ETIM 4: EC000042 - Miniature circuit breaker (MCB)
- ETIM 5: EC000042 - Miniature circuit breaker (MCB)
- ETIM 6: EC000042 - Miniature circuit breaker (MCB)
- Object Classification Code: F
- Extended Product Type: S801S-K8
- Product ID: 2CCS861001R0407
- EAN: 7612271411442
- Minimum Order Quantity: 1 piece
- Customs Tariff Number: 85362020
- EAN: 7612271411442
- Product Net Depth: 82.5 mm
- Product Net Height: 95 mm
- Product Net Weight: 0.25 kg
- Product Net Width: 27 mm
- Package Level 1 Width: 105 mm
- Package Level 1 Length: 33 mm
- Package Level 1 Height: 99 mm
- Package Level 1 Gross Weight: 0.27 kg
- Package Level 1 EAN: 7612271411442
- Package Level 1 Units: 1 piece
- Ambient Air Temperature: Operation -25 ... +60 °C Storage -40 ... +70 °C
- Resistance to Vibrations acc. to IEC 60068-2-6: 2 - 13.2 Hz / 1mm
13.2 - 100Hz / 0.7g
with load 100% x Ie - Environmental Conditions: Damp Heat Cyclic acc. to IEC 60068-2-30 12+12 cycle Damp Heat Cyclic acc. to IEC 60068-2-30 55°C @ 90-96% Damp Heat Cyclic acc. to IEC 60068-2-30 25°C @ 90-100% Dry Heat Test B acc. to IEC 60068-2-2 16 hour @ 55 °C Dry Heat Test B acc. to IEC 60068-2-2 2 hour @ 70 °C
- RoHS Status: Following EU Directive 2002/95/EC August 18, 2005 and amendment
- Number of Poles: 1
- Tripping Characteristic: K
- Rated Current (In): 8 A
- Rated Operational Voltage: 400/690 V AC 125 V DC
- Power Loss: at Rated Operating Conditions per Pole 1.5 W
- Rated Insulation Voltage (Ui): 690 V AC
- Rated Frequency (f): 50 / 60 Hz
Santa Clara Systems se especializa en piezas difíciles de encontrar. Elija de nuestro inventario de exceso y ahorre en 2CCS861001R0407 . Santa Clara Systems tiene 36,195 artículos de ABB.
- Therefore It Can Be Used Worldwide. The Extensive Range Of Accessory Makes The Use Of S801S-K8 More Comfortable. Due To The Fast Arc Extinction Of S801S-K8 Your Application Will Be Secured.
Alternativas
- S801S-K8
- S801S K8
- S801SK8
Errores Tipográficos Comunes
- 2CCS861001R04O7
- 2CCS861001RO407
- 2CCS861001RO4O7
- 2CCS86100IR0407
- 2CCS86100IR04O7
- 2CCS86100IRO407
- 2CCS86100IRO4O7
- 2CCS86100LR0407
- 2CCS86100LR04O7
- 2CCS86100LRO407
- 2CCS86100LRO4O7
- 2CCS8610O1R0407
- 2CCS8610O1R04O7
- 2CCS8610O1RO407
- 2CCS8610O1RO4O7
- 2CCS8610OIR0407
- 2CCS8610OIR04O7
- 2CCS8610OIRO407
- 2CCS8610OIRO4O7
- 2CCS8610OLR0407
- 2CCS8610OLR04O7
- 2CCS8610OLRO407
- 2CCS8610OLRO4O7
- 2CCS861O01R0407
- 2CCS861O01R04O7
Números Adjuntos
- 2CCS861001R0407-A
- 2CCS861001R0407-B
- 2CCS861001R0407-C
- 2CCS861001R0407-D
- 2CCS861001R0407-E
- 2CCS861001R0407-F
- 2CCS861001R0407-G
- 2CCS861001R0407-H
- 2CCS861001R0407-I
- 2CCS861001R0407-J
- 2CCS861001R0407-K
- 2CCS861001R0407-L
- 2CCS861001R0407-M
- 2CCS861001R0407-N
- 2CCS861001R0407-O
- 2CCS861001R0407-P
- 2CCS861001R0407-Q
- 2CCS861001R0407-R
- 2CCS861001R0407-S
- 2CCS861001R0407-T
- 2CCS861001R0407-U
- 2CCS861001R0407-V
- 2CCS861001R0407-W
- 2CCS861001R0407-X
- 2CCS861001R0407-Y
- 2CCS861001R0407-Z
Más Productos Como Este
-
2CCS861001R0404
ABB
-
2CCS861001R0405
ABB
-
2CCS861001R0427
ABB
-
2CCS861001R0447
ABB
Clientes También Están Comprando
-
3RV1 021-1JA10
Siemens
-
IC697 ACC 701 (BATTERY)
General Electric
-
855T-L10
Allen Bradley
-
9001-K35
Square D
Entrega que cumple con sus necesidades

- ✓ Horas Tardes de Envió de la Costa Oeste (5PM Hora del Pacifico)
- ✓ Especialistas en Entrega Directa y Entrega Ciega
- ✓ Empacado por Expertos Estática Reducida
- ✓ Servicio el Mismo Día
- ✓ Mensajero Interno Nacional e Internacional