• ABB 2CDS252001R0467 Circuit Breaker | S202-K16 Product Image
  • ABB 2CDS252001R0467 Circuit Breaker | S202-K16 Product Image
  • Abb 2CDS252001R0467 Barcode

2CDS252001R0467

Resumen del Producto:

  • Poles: 2
  • Current: 16 A
  • Tripping Characteristic: K
  • Extended Product Type: S202-K16
  • Product ID: 2CDS252001R0467
Obtén una Cotización
           o           
  • Descripción: Circuit Breaker | S202-K16
  • Rated Ultimate Short-Circuit Breaking Capacity (Icu): 10 kA 10 kA (DC) kA
  • Rated Service Short-Circuit Breaking Capacity (Ics): 7.5 kA
  • Energy Limiting Class: 3
  • Overvoltage Category: III
  • Pollution Degree: 3
  • Rated Impulse Withstand Voltage (Uimp): 4 kV (6.2 kV @ sea level) kV (5.0 kV @ 2000 m) kV
  • Dielectric Test Voltage: 50 / 60 Hz, 1 min: 2 kV
  • Housing Material: Insulation Group II, RAL 7035
  • Actuator Type: Insulation group II, black, sealable
  • Contact Position Indication: Red ON / Green OFF
  • Degree of Protection: IP20
  • Remarks: IP40 in enclosure with cover
  • Electrical Endurance: 20000 AC cycle
  • Mechanical Endurance: 20000 cycle
  • Terminal Type: Screw Terminals
  • Screw Terminal Type: Failsafe Bi-directional Cylinder-lift Terminal
  • Connecting Capacity: Busbar 10 / 10 mm² Flexible with Ferrule 0.75 ... 25 mm² Flexible 0.75 ... 25 mm² Rigid 0.75 ... 35 mm² Stranded 0.75 ... 35 mm²
  • Tightening Torque: 2.8 N·m
  • Recommended Screw Driver: Pozidriv 2
  • Mounting on DIN Rail: TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
  • Mounting Position: Any
  • Standards: IEC/EN 60898-1 IEC/EN 60947-2 UL 1077
  • Connecting Capacity UL/CSA: Busbar 18-8 AWG Conductor 18-4 AWG
  • Tightening Torque UL/CSA: 25 in·lb
  • Interrupting Rating acc. to UL1077: 6 kA (DC) 10 kA
  • Maximum Operating Voltage UL/CSA: 480Y / 277 V AC
  • Instructions and Manuals: 2CSC400002D0208
  • Data Sheet, Technical Information: 2CSC400002D0208
  • Declaration of Conformity - CE: 2CDK403001D0604
  • RoHS Information: 2CDK400003K0201
  • E-nummer: 2100715
  • ETIM 4: EC000042 - Miniature circuit breaker (MCB)
  • ETIM 5: EC000042 - Miniature circuit breaker (MCB)
  • ETIM 6: EC000042 - Miniature circuit breaker (MCB)
  • eClass: 7.0 27141901
  • UNSPSC: 39121614
  • Object Classification Code: F
  • Poles: 2
  • Current: 16 A
  • Tripping Characteristic: K
  • Extended Product Type: S202-K16
  • Product ID: 2CDS252001R0467
  • EAN: 4016779507417
  • Minimum Order Quantity: 1 piece
  • Customs Tariff Number: 85362010
  • EAN: 4016779507417
  • Product Net Depth: 69 mm
  • Product Net Height: 88 mm
  • Product Net Weight: 0.25 kg
  • Product Net Width: 35 mm
  • Package Level 1 Width: 92 mm
  • Package Level 1 Length: 183 mm
  • Package Level 1 Height: 80 mm
  • Package Level 1 Gross Weight: 1.3 kg
  • Package Level 1 EAN: 4016779608732
  • Package Level 2 Units: 60 piece
  • Package Level 2 Width: 275 mm
  • Package Level 2 Length: 395 mm
  • Package Level 2 Height: 210 mm
  • Package Level 2 Gross Weight: 14.8 kg
  • Package Level 2 EAN: 4016779972680
  • Package Level 1 Units: 5 piece
  • Ambient Air Temperature: Operation -25 ... +55 °C Storage -40 ... +70 °C
  • Resistance to Shock acc. to IEC 60068-2-27: 25g / 2 shocks / 13 ms
  • Resistance to Vibrations acc. to IEC 60068-2-6: 5g, 20 cycles at 5 ... 150 ... 5 Hz with load 0.8 In
  • Environmental Conditions: 28 cycles with 55 °C / 90-96 % and 25 °C / 95-100 %
  • RoHS Status: Following EU Directive 2002/95/EC August 18, 2005 and amendment
  • Number of Poles: 2
  • Tripping Characteristic: K
  • Rated Current (In): 16 A
  • Rated Operational Voltage: acc. to IEC 60898-1 400 V AC acc. to IEC 60947-2 440 V AC
  • Power Loss: 4 W at Rated Operating Conditions per Pole 2 W
  • Rated Insulation Voltage (Ui): acc. to IEC/EN 60664-1 440 V
  • Operational Voltage: Maximum (Incl. Tolerance) 125 V DC Maximum (Incl. Tolerance) 440 V AC Minimum 12 V AC / 12 V DC
  • Rated Frequency (f): 50 Hz 60 Hz
  • Rated Short-Circuit Capacity (Icn): (AC) 6 kA 6 kA (DC) kA
Santa Clara Systems se especializa en piezas difíciles de encontrar. Elija de nuestro inventario de exceso y ahorre en 2CDS252001R0467 . Santa Clara Systems tiene 35,877 artículos de ABB.
Estamos en el proceso de agregar los datos y el material descargable para este artículo. Por favor, busque artículos similares para obtener más información en relación con este producto.

Alternativas

  • S202-K16
  • S202-K16A
  • S202 K16
  • S202 K16A
  • S202K16
  • S202K16A
  • 2CDS252001R0467

Errores Tipográficos Comunes

  • 2CDS252001R04G7
  • 2CDS252001RO467
  • 2CDS252001RO4G7
  • 2CDS25200IR0467
  • 2CDS25200IR04G7
  • 2CDS25200IRO467
  • 2CDS25200IRO4G7
  • 2CDS25200LR0467
  • 2CDS25200LR04G7
  • 2CDS25200LRO467
  • 2CDS25200LRO4G7
  • 2CDS2520O1R0467
  • 2CDS2520O1R04G7
  • 2CDS2520O1RO467
  • 2CDS2520O1RO4G7
  • 2CDS2520OIR0467
  • 2CDS2520OIR04G7
  • 2CDS2520OIRO467
  • 2CDS2520OIRO4G7
  • 2CDS2520OLR0467
  • 2CDS2520OLR04G7
  • 2CDS2520OLRO467
  • 2CDS2520OLRO4G7
  • 2CDS252O01R0467
  • 2CDS252O01R04G7

Números Adjuntos

  • 2CDS252001R0467-A
  • 2CDS252001R0467-B
  • 2CDS252001R0467-C
  • 2CDS252001R0467-D
  • 2CDS252001R0467-E
  • 2CDS252001R0467-F
  • 2CDS252001R0467-G
  • 2CDS252001R0467-H
  • 2CDS252001R0467-I
  • 2CDS252001R0467-J
  • 2CDS252001R0467-K
  • 2CDS252001R0467-L
  • 2CDS252001R0467-M
  • 2CDS252001R0467-N
  • 2CDS252001R0467-O
  • 2CDS252001R0467-P
  • 2CDS252001R0467-Q
  • 2CDS252001R0467-R
  • 2CDS252001R0467-S
  • 2CDS252001R0467-T
  • 2CDS252001R0467-U
  • 2CDS252001R0467-V
  • 2CDS252001R0467-W
  • 2CDS252001R0467-X
  • 2CDS252001R0467-Y
  • 2CDS252001R0467-Z

Clientes También Están Comprando

Entrega que cumple con sus necesidades

Late West Coast Shipping Hours
Horas Tardes de Envió de la Costa Oeste (5PM Hora del Pacifico)
Especialistas en Entrega Directa y Entrega Ciega
Empacado por Expertos Estática Reducida
Servicio el Mismo Día
Mensajero Interno Nacional e Internacional
visa credit card logo mastercard credit card logo discover credit card logo american express credit card logo