• ABB TAE50-30-00-58 TAE50-30-00 42-78V DC Contactor Product Image
  • Abb TAE50-30-00-58 Barcode

TAE50-30-00-58

Let Us Find It

Current response time:

19 Minutes 16 Seconds
  • Description: TAE50-30-00 42-78V DC Contactor
  • Product ID: 1SBL359061R5800
  • Extended Product Type: 1SBL359061R5800
  • Product Net Weight: 1.200 kg
  • Product Net Width: 82 mm
  • Product Net Height: 110 mm
  • Product Net Depth: 108 mm
  • Degree of Protection: acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
  • Ambient Air Temperature: Close to Contactor Fitted with Thermal O/L Relay -25 ... +55 C Close to Contactor for Storage -60 ... +80 C Close to Contactor without Thermal O/L Relay -40 ... +55 C
  • Rated Impulse Withstand Voltage (U<sub>imp</sub>): 8 kV
  • Rated Insulation Voltage (U<sub>i</sub>): acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V
  • Terminal Type: Screw Terminals
  • Number of Auxiliary Contacts NO: 0
  • Number of Auxiliary Contacts NC: 0
  • Connecting Capacity Main Circuit: Flexible with Cable End 6 ... 16 mm Rigid Cable 6 ... 25 mm
  • GOST Certificate: GOST_POCCFRME77B07175
  • Maximum Operating Altitude Permissible: 3000 m
  • Rated Control Circuit Voltage (U<sub>c</sub>): DC Operation 42 78 V
  • Climatic Withstand: acc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II
  • Maximum Mechanical Switching Frequency: 3600 cycles per hour
  • Connecting Capacity Auxiliary Circuit: Flexible with Cable End 0.75 ... 2.5 mm Rigid Cable 1 ... 4 mm
  • Operate Time: Between Coil Energization and NO Contact Closing 30 ... 30 ms Between Coil De-energization and NO Contact Opening 5 ... 15 ms
  • Number of Main Contacts NO: 3
  • Number of Main Contacts NC: 0
  • Short-Circuit Protective Devices: gG Type Fuses 100 A
  • Maximum Breaking Capacity: cos phi=0.45 (cos phi=0.35 for Ie &gt; 100 A) at 440 V 1300 A cos phi=0.45 (cos phi=0.35 for Ie &gt; 100 A) at 690 V 630 A
  • Coil Consumption: Holding DC (Umin / Umax) 1.7 / 6.5 W Pull-in at Max. Rated Control Circuit Voltage DC 450 W Pull-in DC (Umin / Umax) 120 / 250 W
  • Connecting terminals (delivered in open position) Main poles: M 6 (+,-) pozidriv 2 screws with 1x (13 x 10 mm) connector
  • EAN: 3471522114051
  • Minimum Order Quantity: 1 piece
  • Customs Tariff Number: 85369085
  • Package Level 1 Width: 140 mm
  • Package Level 1 Length: 146 mm
  • Package Level 1 Height: 96 mm
  • Package Level 1 Gross Weight: 1.2 kg
  • Package Level 1 EAN: 3471522114051
  • Package Level 2 Units: 20 piece
  • Package Level 3 Units: 160 piece
  • Package Level 1 Units: 1 piece
  • Rated Operational Voltage: Main Circuit 1000 V
  • Conventional Free-air Thermal Current (I<sub>th</sub>): acc. to IEC 60947-4-1, Open Contactors q = 40 C 100 A
  • Rated Operational Current AC-1 (I<sub>e</sub>): (690 V) 40 C 100 A (690 V) 55 C 85 A
  • Rated Operational Current AC-3 (I<sub>e</sub>): (1000 V) 55 C 23 A (220 / 230 / 240 V) 55 C 53 A (380 / 400 V) 55 C 50 A (415 V) 55 C 50 A (440 V) 55 C 45 A (500 V) 55 C 45 A (690 V) 55 C 35 A
  • Rated Operational Power AC-3 (P<sub>e</sub>): (220 / 230 / 240 V) 15 kW (380 / 400 V) 22 kW (415 V) 25 kW (440 V) 25 kW (500 V) 30 kW (690 V) 30 kW
  • Rated Breaking Capacity AC-3 acc. to IEC 60947-4-1: 8 x Ie AC-3
  • Rated Making Capacity AC-3 acc. to IEC 60947-4-1: 10 x Ie AC-3
  • Rated Short-time Withstand Current (I<sub>cw</sub>): at 40 C Ambient Temp, in Free Air, from a Cold State 10 s 650 A at 40 C Ambient Temp, in Free Air, from a Cold State 15 min 110 A at 40 C Ambient Temp, in Free Air, from a Cold State 1 min 250 A at 40 C Ambient Temp, in Free Air, from a Cold State 1 s 1000 A at 40 C Ambient Temp, in Free Air, from a Cold State 30 s 370 A
  • Maximum Electrical Switching Frequency: AC-1 300 cycles per hour AC-2 / AC-4 150 cycles per hour AC-3 300 cycles per hour
  • Resistance to Shock acc. to IEC 60068-2-27: Shock Direction: A 20 g Closed, Shock Direction: B1 10 g Open, Shock Direction: B1 5 g Shock Direction: B2 15 g Shock Direction: C1 20 g Shock Direction: C2 20 g
  • RoHS Status: Following EU Directive 2002/95/EC August 18, 2005 and amendment
  • Instructions and Manuals: FPTC407700P0003
  • CB Certificate: CB_FR3397-60022335-515371B
  • CCC Certificate: CCC_2004010304138315
  • Data Sheet, Technical Information: 1SNC001003C0202
  • Declaration of Conformity - CE: 1SBD250804U1000
  • EAC Certificate: EAC_RU C-FR ME77 B01010
  • RoHS Information: 1SBD350072R1000
  • ETIM 4: EC000066 - Magnet contactor, AC-switching
  • ETIM 5: EC000066 - Magnet contactor, AC-switching
  • ETIM 6: EC000066 - Power contactor, AC switching
  • UNSPSC: 39121529
  • Object Classification Code: Q
Santa Clara Systems specializes in hard-to-find parts. Choose from our overstock inventory and save on TAE50-30-00-58 . Santa Clara Systems carries 36,673 items from ABB.
  • Front And Side-Mounted Add-On Auxiliary Contact Blocks - Control Circuit: Dc Operated With Standard Double-Winding Dc Coils (With Add-On Factory-Mounted Lagging Contact For Insertion Of The&quot;holding&quot; Winding). Tae... Contactors Offer A Large Coil Voltage Range - Accessories: A Wide Range Of Accessories Is Available.
  • Tae50 Contactors Are Mainly Used For Controlling 3-Phase Motors And Generally For Controlling Power Circuits Up To 690 V Ac / 1000 V Ac Or 220 V Dc. The Contactors Can Also Be Used For Many Other Applications Such As Isolation
  • Capacitor Switching
  • Lighting. The Tae... Series 1-Stack 3-Pole Contactors Are Of The Block Type Design. - Main Poles And Auxiliary Contact Blocks: 3 Main Poles

Alternates

  • 1SBL359061R5800
  • TAE50 30 00 58
  • TAE50300058

Common Typos

  • TAE50-30-00-5B
  • TAE50-30-00-S8
  • TAE50-30-00-SB
  • TAE50-30-0O-58
  • TAE50-30-0O-5B
  • TAE50-30-0O-S8
  • TAE50-30-0O-SB
  • TAE50-30-O0-58
  • TAE50-30-O0-5B
  • TAE50-30-O0-S8
  • TAE50-30-O0-SB
  • TAE50-30-OO-58
  • TAE50-30-OO-5B
  • TAE50-30-OO-S8
  • TAE50-30-OO-SB
  • TAE50-3O-00-58
  • TAE50-3O-00-5B
  • TAE50-3O-00-S8
  • TAE50-3O-00-SB
  • TAE50-3O-0O-58
  • TAE50-3O-0O-5B
  • TAE50-3O-0O-S8
  • TAE50-3O-0O-SB
  • TAE50-3O-O0-58
  • TAE50-3O-O0-5B
  • TAE50-3O-O0-S8

Appended Numbers

  • TAE50-30-00-58-A
  • TAE50-30-00-58-B
  • TAE50-30-00-58-C
  • TAE50-30-00-58-D
  • TAE50-30-00-58-E
  • TAE50-30-00-58-F
  • TAE50-30-00-58-G
  • TAE50-30-00-58-H
  • TAE50-30-00-58-I
  • TAE50-30-00-58-J
  • TAE50-30-00-58-K
  • TAE50-30-00-58-L
  • TAE50-30-00-58-M
  • TAE50-30-00-58-N
  • TAE50-30-00-58-O
  • TAE50-30-00-58-P
  • TAE50-30-00-58-Q
  • TAE50-30-00-58-R
  • TAE50-30-00-58-S
  • TAE50-30-00-58-T
  • TAE50-30-00-58-U
  • TAE50-30-00-58-V
  • TAE50-30-00-58-W
  • TAE50-30-00-58-X
  • TAE50-30-00-58-Y
  • TAE50-30-00-58-Z

More Products Like This

Customers Are Also Buying

We Deliver!

Late West Coast Shipping Hours
Late West Coast Shipping (5PM PST)
Drop-Ship and Blind-Ship Specialists
Expertly Packed Static-Limited
Same-Day Service
In-House Courier
visa credit card logo mastercard credit card logo discover credit card logo american express credit card logo

Customers we work with

3M logo
Kaiser Permanente logo
Safeway Logo
Georgia-Pacific logo
Coca Cola logo
duke energy logo
BART logo
Pepsi logo
LA DWP logo
US Navy logo
Dean Foods logo
ConAgra Brands logo