• ABB AF95-30-22-72 AF95-30-22 20-60V DC Contactor Product Image
  • Abb AF95-30-22-72 Barcode

AF95-30-22-72

Let Us Find It

Current response time:

By 5AM PT on Tuesday
  • Description: AF95-30-22 20-60V DC Contactor
  • Product ID: 1SFL437001R7222
  • Extended Product Type: 1SFL437001R7222
  • Product Net Weight: 2.100 kg
  • Product Net Width: 90.0 mm
  • Product Net Height: 148.0 mm
  • Product Net Depth: 156.5 mm
  • Degree of Protection: acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
  • Ambient Air Temperature: Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25+50 C Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40+70 C Close to Contactor for Storage -60+80 C
  • Rated Impulse Withstand Voltage (U<sub>imp</sub>): Main Circuit 8 kV
  • Rated Insulation Voltage (U<sub>i</sub>): acc. to UL/CSA 600 V acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V
  • Terminal Type: Cable Clamp
  • Number of Auxiliary Contacts NO: 2
  • Number of Auxiliary Contacts NC: 2
  • Mechanical Durability: 10 million
  • Connecting Capacity Main Circuit: Flexible with Cable End 1x1070 mm Bar 30 mm Rigid 2x665 mm
  • Maximum Operating Voltage UL/CSA: Main Circuit 600 V
  • Maximum Operating Altitude Permissible: 3000 m
  • Rated Control Circuit Voltage (U<sub>c</sub>): DC Operation 20 60 V
  • Maximum Mechanical Switching Frequency: 300 cycles per hour
  • Connecting Capacity Auxiliary Circuit: Solid 2x14 mm Flexible with Insulated Ferrule 2x0.752.5 mm Stranded 2x14 mm Flexible 2x0.752.5 mm Flexible with Ferrule 2x0.752.5 mm
  • Operate Time: Between Coil Energization and NO Contact Closing 3080 ms Between Coil De-energization and NO Contact Opening 55125 ms Between Coil De-energization and NC Contact Closing 60130 ms Between Coil Energization and NC Contact Opening 2777 ms
  • Number of Main Contacts NO: 3
  • GL Certificate: GL_20260-04HH
  • Number of Main Contacts NC: 0
  • Short-Circuit Protective Devices: gG Type Fuses 160 A
  • Maximum Breaking Capacity: cos phi=0.45 (cos phi=0.35 for Ie &gt; 100 A) at 440 V 1160 A cos phi=0.45 (cos phi=0.35 for Ie &gt; 100 A) at 690 V 800 A
  • Coil Consumption: Pull-in at Max. Rated Control Circuit Voltage 60 Hz 350 V&#183;A Holding at Max. Rated Control Circuit Voltage DC 2 W Holding at Max. Rated Control Circuit Voltage 50 Hz 7 V&#183;A Pull-in at Max. Rated Control Circuit Voltage DC 400 W Pull-in at Max. Rated Control Circuit Voltage 50 Hz 350 V&#183;A Holding at Max. Rated Control Circuit Voltage 60 Hz 7 V&#183;A
  • Coil Operating Limits: (acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at 70 C) C
  • Connecting terminals (delivered in open position) Main poles: M8 hexagon socket screw with single connector
  • Horsepower Rating UL/CSA: (208 V AC) Three Phase 30 Hp (440 ... 480 V AC) Three Phase 60 Hp (550 ... 600 V AC) Three Phase 75 Hp (220 ... 240 V AC) Three Phase 30 Hp (200 V AC) Three Phase 30 Hp
  • General Use Rating UL/CSA: (600 V AC) 125 A
  • EAN: 7320500239650
  • Minimum Order Quantity: 1 piece
  • Customs Tariff Number: 85364900
  • Package Level 1 Width: 140 mm
  • Package Level 1 Length: 140 mm
  • Package Level 1 Height: 170 mm
  • Package Level 1 Gross Weight: 2.1 kg
  • Package Level 1 EAN: 7320500239650
  • Package Level 1 Units: 1 piece
  • Rated Operational Voltage: Main Circuit 1000 V
  • Conventional Free-air Thermal Current (I<sub>th</sub>): acc. to IEC 60947-4-1, Open Contactors q = 40 C 145 A
  • Rated Operational Current AC-1 (I<sub>e</sub>): (690 V) 55 C 135 A (690 V) 40 C 145 A (690 V) 70 C 115 A
  • Rated Operational Current AC-3 (I<sub>e</sub>): (1000 V) 55 C 30 A (220 / 230 / 240 V) 55 C 96 A (690 V) 55 C 65 A (415 V) 55 C 96 A (440 V) 55 C 93 A (380 / 400 V) 55 C 96 A (500 V) 55 C 80 A
  • Rated Operational Power AC-3 (P<sub>e</sub>): (500 V) 55 kW (1000 V) 40 kW (690 V) 55 kW (220 / 230 / 240 V) 25 kW (380 / 400 V) 45 kW (440 V) 55 kW (415 V) 55 kW
  • Rated Breaking Capacity AC-3 acc. to IEC 60947-4-1: 8 x Ie AC-3
  • Rated Making Capacity AC-3 acc. to IEC 60947-4-1: 10 x Ie AC-3
  • Maximum Electrical Switching Frequency: AC-3 300 cycles per hour AC-1 300 cycles per hour AC-2 / AC-4 150 cycles per hour
  • Rated Operational Current DC-1 (I<sub>e</sub>): (110 V) 2 Poles in Series, 40 C 145 A (220 V) 3 Poles in Series, 40 C 145 A
  • Rated Operational Current DC-3 (I<sub>e</sub>): (110 V) 2 Poles in Series, 40 C 145 A (220 V) 3 Poles in Series, 40 C 145 A
  • Rated Operational Current DC-5 (I<sub>e</sub>): (110 V) 2 Poles in Series, 40 C 145 A (220 V) 3 Poles in Series, 40 C 145 A
  • Resistance to Shock acc. to IEC 60068-2-27: Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: A 20 g Half-sine Pulse for 11 ms, No Change in Contact Position, Closed, Shock Direction: A 20 g Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: C2 20 g Half-sine Pulse for 11 ms, No Change in Contact Position, Closed, Shock Direction: B1 15 g Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: C1 20 g Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: B2 15 g Half-sine Pulse for 11 ms, No Change in Contact Position, Closed, Shock Direction: C2 20 g Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: B1 5 g Half-sine Pulse for 11 ms, No Change in Contact Position, Closed, Shock Direction: C1 20 g
  • RoHS Status: Following EU Directive 2002/95/EC August 18, 2005 and amendment
  • Instructions and Manuals: 5309660-60
  • BV Certificate: 13409/C0 BV
  • CB Certificate: SE-73661
  • CCC Certificate: CQC_2002010304007860
  • Data Sheet, Technical Information: 1SBC100122C0202
  • Declaration of Conformity - CE: 1SFA1-66
  • LR Certificate: LR_04-00015-E1
  • RINA Certificate: ELE060313XG/002
  • RMRS Certificate: RMRS_12-03683-315
  • RoHS Information: 1SFC101055D0202
  • TV Certificate: MHM-EST-7.70017788e
  • ETIM 4: EC000066 - Magnet contactor, AC-switching
  • ETIM 5: EC000066 - Magnet contactor, AC-switching
  • UNSPSC: 39121529
  • Object Classification Code: Q
Santa Clara Systems specializes in hard-to-find parts. Choose from our overstock inventory and save on AF95-30-22-72 . Santa Clara Systems carries 36,673 items from ABB.
  • Dc
  • A 3-Phase Contactor Suitable For Various Applications Such As Motor Starting
  • Isolation
  • By-Pass And Distribution Application Up To Max 1000 V. Operated With Wide Control Voltage Range 20-60 V

Alternates

  • 1SFL437001R7222
  • AF95 30 22 72
  • AF95302272

Common Typos

  • AF95-30-22-7Z
  • AF95-30-2Z-72
  • AF95-30-2Z-7Z
  • AF95-30-Z2-72
  • AF95-30-Z2-7Z
  • AF95-30-ZZ-72
  • AF95-30-ZZ-7Z
  • AF95-3O-22-72
  • AF95-3O-22-7Z
  • AF95-3O-2Z-72
  • AF95-3O-2Z-7Z
  • AF95-3O-Z2-72
  • AF95-3O-Z2-7Z
  • AF95-3O-ZZ-72
  • AF95-3O-ZZ-7Z
  • AF9S-30-22-72
  • AF9S-30-22-7Z
  • AF9S-30-2Z-72
  • AF9S-30-2Z-7Z
  • AF9S-30-Z2-72
  • AF9S-30-Z2-7Z
  • AF9S-30-ZZ-72
  • AF9S-30-ZZ-7Z
  • AF9S-3O-22-72
  • AF9S-3O-22-7Z
  • AF9S-3O-2Z-72

Appended Numbers

  • AF95-30-22-72-A
  • AF95-30-22-72-B
  • AF95-30-22-72-C
  • AF95-30-22-72-D
  • AF95-30-22-72-E
  • AF95-30-22-72-F
  • AF95-30-22-72-G
  • AF95-30-22-72-H
  • AF95-30-22-72-I
  • AF95-30-22-72-J
  • AF95-30-22-72-K
  • AF95-30-22-72-L
  • AF95-30-22-72-M
  • AF95-30-22-72-N
  • AF95-30-22-72-O
  • AF95-30-22-72-P
  • AF95-30-22-72-Q
  • AF95-30-22-72-R
  • AF95-30-22-72-S
  • AF95-30-22-72-T
  • AF95-30-22-72-U
  • AF95-30-22-72-V
  • AF95-30-22-72-W
  • AF95-30-22-72-X
  • AF95-30-22-72-Y
  • AF95-30-22-72-Z

More Products Like This

Customers Are Also Buying

We Deliver!

Late West Coast Shipping Hours
Late West Coast Shipping (5PM PST)
Drop-Ship and Blind-Ship Specialists
Expertly Packed Static-Limited
Same-Day Service
In-House Courier
visa credit card logo mastercard credit card logo discover credit card logo american express credit card logo

Customers we work with

3M logo
Kaiser Permanente logo
Safeway Logo
Georgia-Pacific logo
Coca Cola logo
duke energy logo
BART logo
Pepsi logo
LA DWP logo
US Navy logo
Dean Foods logo
ConAgra Brands logo