• ABB 1SBL177201R1300 AF16-40-00-13 100-250V50/60HZ-DC Contactor Product Image
  • Abb 1SBL177201R1300 Barcode

1SBL177201R1300

Sommaire du Produit:

  • Extended Product Type: AF16-40-00-13
  • Product ID: 1SBL177201R1300
  • EAN: 3471523115132
  • Minimum Order Quantity: 1 piece
  • Customs Tariff Number: 85369085
Permettez-Nous de le Trouver
           ou           
  • Description: AF16-40-00-13 100-250V50/60HZ-DC Contactor
  • Operate Time: Between Coil De-energization and NC Contact Closing 13...98 ms Between Coil De-energization and NO Contact Opening 11...95 ms Between Coil Energization and NC Contact Opening 38...90 ms Between Coil Energization and NO Contact Closing 40...95 ms
  • Connecting Capacity Main Circuit: Flexible with Insulated Ferrule 1x 0.75...4 mm² Flexible with Insulated Ferrule 2x 0.75...2.5 mm² Flexible with Ferrule 1/2x 0.75...6 mm² Rigid 1/2x 1...6 mm²
  • Connecting Capacity Control Circuit: Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm² Rigid 1/2x 1 ... 2.5 mm²
  • Wire Stripping Length: Control Circuit 10 mm Main Circuit 10 mm
  • Degree of Protection: acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20
  • Terminal Type: Screw Terminals
  • Number of Main Contacts NO: 4
  • Climatic Withstand: Category B according to IEC 60947-1 Annex Q
  • Maximum Operating Altitude Permissible: 3000 m
  • Resistance to Vibrations acc. to IEC 60068-2-6: 5...300 Hz 4 g closed position / 2 g open position
  • Resistance to Shock acc. to IEC 60068-2-27: Closed, Shock Direction: B1 25 g Open, Shock Direction: B1 5 g Shock Direction: A 30 g Shock Direction: B2 15 g Shock Direction: C1 25 g Shock Direction: C2 25 g
  • RoHS Status: Planned to follow EU Directive 2002/95/EC August 18, 2005 and amendment after 2008 Q1
  • Ambient Air Temperature: Close to Contactor for Storage -60...+80 °C Near Contactor for Operation in Free Air -40 ... +70 °C
  • General Use Rating UL/CSA: (600 V AC) 30 A
  • Tightening Torque UL/CSA: Control Circuit 11 in·lb Main Circuit 13 in·lb
  • Instructions and Manuals: 1SBC101027M6801
  • ABS Certificate: ABS_15-GE1349500-PDA_90682247
  • CB Certificate: CB_SE_70857M1
  • CCC Certificate: CCC_2010010304445624
  • cUL Certificate: UL_20100802-E319322-3-1
  • Data Sheet, Technical Information: 1SBC101420D0201
  • Declaration of Conformity - CE: 1SBD250001U1000
  • DNV Certificate: DNV-GL_E13871
  • EAC Certificate: EAC_RU C-FR ME77 B01010
  • GL Certificate: DNV-GL_E13871
  • GOST Certificate: GOST_POCCFR.ME77.B07175.pdf
  • LR Certificate: LRS_1300087E1
  • RINA Certificate: RINA_ELE084013XG
  • RMRS Certificate: RMRS_1400682124
  • RoHS Information: 1SBD251011E1000
  • E-nummer: 3211398
  • ETIM 4: EC000066 - Magnet contactor, AC-switching
  • ETIM 5: EC000066 - Magnet contactor, AC-switching
  • ETIM 6: EC000066 - Power contactor, AC switching
  • UNSPSC: 39121529
  • Object Classification Code: Q
  • Extended Product Type: AF16-40-00-13
  • Product ID: 1SBL177201R1300
  • EAN: 3471523115132
  • Minimum Order Quantity: 1 piece
  • Customs Tariff Number: 85369085
  • EAN: 3471523115132
  • Product Net Depth: 77 mm
  • Product Net Height: 86 mm
  • Product Net Weight: 0.270 kg
  • Product Net Width: 45 mm
  • Package Level 1 Width: 87 mm
  • Package Level 1 Length: 79 mm
  • Package Level 1 Height: 47 mm
  • Package Level 1 Gross Weight: 0.27 kg
  • Package Level 1 EAN: 3471523115132
  • Package Level 2 Units: 54 piece
  • Package Level 2 Width: 250 mm
  • Package Level 2 Length: 300 mm
  • Package Level 2 Height: 315 mm
  • Package Level 3 Units: 1296 piece
  • Package Level 1 Units: 1 piece
  • Number of Main Contacts NC: 0
  • Number of Auxiliary Contacts NO: 0
  • Number of Auxiliary Contacts NC: 0
  • Standards: IEC 60947-1 / 60947-4-1 and EN 60947-1 / 60947-4-1, UL 508, CSA C22.2 N°14
  • Rated Operational Voltage: Main Circuit 690 V
  • Rated Frequency (f): Main Circuit 50 / 60 Hz
  • Conventional Free-air Thermal Current (Ith): acc. to IEC 60947-4-1, Open Contactors q = 40 °C 35 A
  • Rated Operational Current AC-1 (Ie): (690 V) 40 °C 30 A (690 V) 60 °C 30 A (690 V) 70 °C 26 A
  • Rated Operational Current AC-3 (Ie): (220 / 230 / 240 V) 60 °C 18 A (380 / 400 V) 60 °C 18 A (415 V) 60 °C 18 A (440 V) 60 °C 18 A (500 V) 60 °C 15 A (690 V) 60 °C 10.5 A
  • Rated Operational Power AC-3 (Pe): (220 / 230 / 240 V) 4 kW (380 / 400 V) 7.5 kW (400 V) 7.5 kW (415 V) 9 kW (440 V) 9 kW (500 V) 9 kW (690 V) 9 kW
  • Rated Short-time Withstand Current (Icw): at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 150 A at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 35 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 60 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 300 A at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 80 A
  • Maximum Breaking Capacity: cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 250 A cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 106 A
  • Maximum Electrical Switching Frequency: AC-1 600 cycles per hour
  • Rated Insulation Voltage (Ui): acc. to UL/CSA 600 V acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V
  • Rated Impulse Withstand Voltage (Uimp): 6 kV
  • Maximum Mechanical Switching Frequency: 3600 cycles per hour
  • Rated Control Circuit Voltage (Uc): 50 Hz 100 ... 250 V 60 Hz 100 ... 250 V DC Operation 100 ... 250 V
Santa Clara Systems spécialise dans les pièces difficiles à trouver. Choisissez parmi notre inventaire de surstock et économiser de l’argent sur 1SBL177201R1300 . Santa Clara Systems se vend 35,881 articles de ABB.
  • Af16 4-Pole Contactors Are Used For Controlling Power Circuits Up To 690 V Ac And 440 V Dc. They Are Mainly Used For Controlling Non-Inductive Or Slightly Inductive Loads (I.E. Resistance Furnaces...). Af... Contactors Include An Electronic Coil Interface Accepting A Wide Control Voltage Uc Min. ... Uc Max. Only Four Coils Cover Control Voltages Between 24...500 V 50/60 Hz Or 20...500 V Dc. Af Contactors Can Manage Large Control Voltage Variations. One Coil Can Be Used For Different Control Voltages Used Worldwide Without Any Coil Change. Af Contactors Have Built-In Surge Protection And Do Not Require Additional Surge Suppressors. The Af... Series 4-Pole Contactors Are Of The Block Type Design. - Main Poles And Auxiliary Contact Blocks: 4 N.O. Main Poles
  • Af16 4-Pole Contactors Are Used For Controlling Power Circuits Up To 690 V Ac And 440 V Dc. They Are Mainly Used For Controlling Non-Inductive Or Slightly Inductive Loads (I.E. Resistance Furnaces...). Af... Contactors Include An Electronic Coil Interface Accepting A Wide Control Voltage Uc Min. ... Uc Max. Only Four Coils Cover Control Voltages Between 24...500 V 50/60 Hz Or 20...500 V Dc. Af Contactors Can Manage Large Control Voltage Variations. One Coil Can Be Used For Different Control Voltages Used Worldwide Without Any Coil Change. Af Contactors Have Built-In Surge Protection And Do Not Require Additional Surge Suppressors. The Af... Series 4-Pole Contactors Are Of The Block Type Design. - Main Poles And Auxiliary Contact Blocks: 4 N.O. Main Poles
  • Front And Side-Mounted Add-On Auxiliary Contact Blocks (Mechanically-Linked Auxiliary Contacts Compliant With Annex L Of Iec 60947-5-1. N.C. Mirror Contacts Compliant With Annex F Of Iec 60947-4-1) - Control Circuit: Ac Or Dc Operated - Accessories: A Wide Range Of Accessories Is Available.
  • Suppléants

    • AF16-40-00-13
    • AF16 40 00 13
    • AF16400013

    Fautes de Frappe Commun

    • 1SBL177201R130O
    • 1SBL177201R13O0
    • 1SBL177201R13OO
    • 1SBL177201RI300
    • 1SBL177201RI30O
    • 1SBL177201RI3O0
    • 1SBL177201RI3OO
    • 1SBL177201RL300
    • 1SBL177201RL30O
    • 1SBL177201RL3O0
    • 1SBL177201RL3OO
    • 1SBL17720IR1300
    • 1SBL17720IR130O
    • 1SBL17720IR13O0
    • 1SBL17720IR13OO
    • 1SBL17720IRI300
    • 1SBL17720IRI30O
    • 1SBL17720IRI3O0
    • 1SBL17720IRI3OO
    • 1SBL17720IRL300
    • 1SBL17720IRL30O
    • 1SBL17720IRL3O0
    • 1SBL17720IRL3OO
    • 1SBL17720LR1300
    • 1SBL17720LR130O

    Numéros Annexées

    • 1SBL177201R1300-A
    • 1SBL177201R1300-B
    • 1SBL177201R1300-C
    • 1SBL177201R1300-D
    • 1SBL177201R1300-E
    • 1SBL177201R1300-F
    • 1SBL177201R1300-G
    • 1SBL177201R1300-H
    • 1SBL177201R1300-I
    • 1SBL177201R1300-J
    • 1SBL177201R1300-K
    • 1SBL177201R1300-L
    • 1SBL177201R1300-M
    • 1SBL177201R1300-N
    • 1SBL177201R1300-O
    • 1SBL177201R1300-P
    • 1SBL177201R1300-Q
    • 1SBL177201R1300-R
    • 1SBL177201R1300-S
    • 1SBL177201R1300-T
    • 1SBL177201R1300-U
    • 1SBL177201R1300-V
    • 1SBL177201R1300-W
    • 1SBL177201R1300-X
    • 1SBL177201R1300-Y
    • 1SBL177201R1300-Z

    Plus de Produits de ce Genre

    Customers Are Also Buying

    Livraison qui Répond à Vos Besoins

    Late West Coast Shipping Hours
    Livraison Rapide pour le Côte Ouest (17 heures, heure du Pacifique)
    Spécialistes de l’Expédition directe au détaillant et d’Envoi Aveugle
    Habilement Emballé Statique-limitée
    Service le Jour Même
    Courier Intra-Muros Nationale et Internationale
    visa credit card logo mastercard credit card logo discover credit card logo american express credit card logo