1SBL243001R8910

Sommaire du Produit:

  • Extended Product Type: AL26-30-10 240V DC
  • Product ID: 1SBL243001R8910
  • EAN: 3471522281890
  • Minimum Order Quantity: 1 piece
  • Customs Tariff Number: 85369085
Permettez-Nous de le Trouver
           ou           
  • Description: AL26-30-10 240V DC Contactor
  • Rated Impulse Withstand Voltage (Uimp): 8 kV
  • Mechanical Durability: 10 million
  • Maximum Mechanical Switching Frequency: 3600 cycles per hour
  • Coil Operating Limits: (acc. to IEC 60947-4-1) 0.85 ... 1.1 x Uc (at ? ? 55 °C) °C
  • Rated Control Circuit Voltage (Uc): DC Operation 240 V
  • Coil Consumption: Average Holding Value, from Warm State 3.5 W Average Pull-in Value, from Cold State 3.5 W
  • Operate Time: Between Coil Energization and NO Contact Closing 55 ... 110 ms Between Coil De-energization and NO Contact Opening 12 ... 18 ms
  • Connecting Capacity Main Circuit: Flexible with Cable End 0.75 ... 4 mm² Rigid Cable 1.5 ... 6 mm²
  • Connecting Capacity Auxiliary Circuit: Flexible with Cable End 0.75 ... 2.5 mm² Rigid Cable 1 ... 4 mm²
  • Degree of Protection: acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
  • Connecting terminals (delivered in open position) Main poles: M 4 (+,-) pozidriv 2 screw with cable clamp
  • Terminal Type: Screw Terminals
  • Number of Main Contacts NO: 3
  • Climatic Withstand: acc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II
  • Maximum Operating Altitude Permissible: 3000 m
  • Resistance to Shock acc. to IEC 60068-2-27: Closed, Shock Direction: A 20 g Open, Shock Direction: A 10 g Closed, Shock Direction: B1 15 g Open, Shock Direction: B1 5 g Shock Direction: B2 10 g Closed, Shock Direction: C1 20 g Open, Shock Direction: C1 8 g Closed, Shock Direction: C2 14 g Open, Shock Direction: C2 8 g
  • RoHS Status: Following EU Directive 2002/95/EC August 18, 2005 and amendment
  • Ambient Air Temperature: Close to Contactor Fitted with Thermal O/L Relay -25 ... +55 °C Close to Contactor for Storage -60 ... +80 °C Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... +55 °C Close to Contactor without Thermal O/L Relay (Uc) -40 ... +70 °C
  • Instructions and Manuals: 1SBC101007M5501
  • Instructions and Manuals (Part 2): 1SBC101008M5501
  • ASEFA Certificate: ASEFA_05503BT
  • CB Certificate: CB_FR3192_60016914_509747
  • CCC Certificate: CCC_2004010304112231
  • CSA Certificate: CSA_1033838_LR056745
  • Data Sheet, Technical Information: 1SBC100122C0202_Ch02
  • Declaration of Conformity - CE: 1SBD250804U1000
  • GL Certificate: GL_26144_05HH
  • GOST Certificate: GOST_POCCFRME77B07175
  • LOVAG Certificate: LOVAG_FR03024-FR03032
  • RoHS Information: 1SBD350055R1000
  • ETIM 4: EC000066 - Magnet contactor, AC-switching
  • ETIM 5: EC000066 - Magnet contactor, AC-switching
  • ETIM 6: EC000066 - Power contactor, AC switching
  • UNSPSC: 39121529
  • Object Classification Code: Q
  • Extended Product Type: AL26-30-10 240V DC
  • Product ID: 1SBL243001R8910
  • EAN: 3471522281890
  • Minimum Order Quantity: 1 piece
  • Customs Tariff Number: 85369085
  • EAN: 3471522281890
  • Product Net Depth: 110.6 mm
  • Product Net Height: 90 mm
  • Product Net Weight: 0.750 kg
  • Product Net Width: 54 mm
  • Package Level 1 Width: 100 mm
  • Package Level 1 Length: 134 mm
  • Package Level 1 Height: 62 mm
  • Package Level 1 Gross Weight: 0.75 kg
  • Package Level 1 EAN: 3471522281890
  • Package Level 2 Units: 20 piece
  • Package Level 3 Units: 384 piece
  • Package Level 1 Units: 1 piece
  • Number of Main Contacts NC: 0
  • Number of Auxiliary Contacts NO: 1
  • Number of Auxiliary Contacts NC: 0
  • Rated Operational Voltage: Main Circuit 690 V Auxiliary Circuit 690 V
  • Rated Frequency (f): Supply Circuit 50 Hz Supply Circuit 60 Hz
  • Conventional Free-air Thermal Current (Ith): acc. to IEC 60947-4-1, Open Contactors q = 40 °C 45 A acc. to IEC 60947-5-1, q = 40 °C 16 A
  • Rated Operational Current AC-1 (Ie): (690 V) 40 °C 45 A (690 V) 55 °C 40 A (690 V) 70 °C 32 A
  • Rated Operational Current AC-3 (Ie): (220 / 230 / 240 V) 55 °C 26 A (380 / 400 V) 55 °C 26 A (415 V) 55 °C 26 A (440 V) 55 °C 26 A (500 V) 55 °C 22 A (690 V) 55 °C 13 A
  • Rated Operational Power AC-3 (Pe): (220 / 230 / 240 V) 6.5 kW (380 / 400 V) 11 kW (415 V) 11 kW (440 V) 15 kW (500 V) 15 kW (690 V) 11 kW
  • Rated Breaking Capacity AC-3 acc. to IEC 60947-4-1: 8 x Ie AC-3
  • Rated Making Capacity AC-3 acc. to IEC 60947-4-1: 10 x Ie AC-3
  • Rated Operational Current AC-15 (Ie): (220 / 240 V) 4 A (24 / 127 V) 6 A (380 / 440 V) 3 A (500 V) 2 A (690 V) 2 A
  • Short-Circuit Protective Devices: Auxiliary Circuit - gG Type Fuses 10 A gG Type Fuses 50 A
  • Rated Short-time Withstand Current (Icw): at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 210 A at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 45 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 90 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 400 A at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 110 A for 0.1 s 140 A for 1 s 100 A
  • Maximum Breaking Capacity: cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 420 A cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 106 A
  • Maximum Electrical Switching Frequency: AC-1 600 cycles per hour AC-2 / AC-4 300 cycles per hour AC-3 1200 cycles per hour
  • Rated Operational Current DC-13 (Ie): (125 V) 1.1 / 138 A (24 V) 6 / 144 A (250 V) 0.55 / 138 A (48 V) 2.8 / 134 A (72 V) 2 / 144 A
  • Rated Insulation Voltage (Ui): acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V acc. to UL/CSA 600 V
Santa Clara Systems spécialise dans les pièces difficiles à trouver. Choisissez parmi notre inventaire de surstock et économiser de l’argent sur 1SBL243001R8910 . Santa Clara Systems se vend 35,866 articles de ABB.
  • 1 Built-In Auxiliary Contact
  • Front And Side-Mounted Add-On Auxiliary Contact Blocks - Control Circuit: Dc Operated With Solid Core Magnet Circuit. The Polarity On The Coil Terminals (A1+ And A2-) Must Be Respected - Accessories: A Wide Range Of Accessories Is Available. Al... Contactors Are Fitted With Low Consumption Dc Coils And Are Suitable For A Direct Control By Plc Outputs.
  • Al26 Contactors Are Mainly Used For Controlling 3-Phase Motors And Generally For Controlling Power Circuits Up To 690 V Ac Or 220 V Dc. The Contactors Can Also Be Used For Many Other Applications Such As Isolation
  • Capacitor Switching
  • Lighting. The Al... Series 1-Stack 3-Pole Contactors Are Of The Block Type Design. - Main Poles And Auxiliary Contact Blocks: 3 Main Poles
  • Suppléants

    • AL26-30-10-89
    • AL26 30 10 89
    • AL26301089

    Fautes de Frappe Commun

    • 1SBL243001R891O
    • 1SBL243001R89I0
    • 1SBL243001R89IO
    • 1SBL243001R89L0
    • 1SBL243001R89LO
    • 1SBL243001RB910
    • 1SBL243001RB91O
    • 1SBL243001RB9I0
    • 1SBL243001RB9IO
    • 1SBL243001RB9L0
    • 1SBL243001RB9LO
    • 1SBL24300IR8910
    • 1SBL24300IR891O
    • 1SBL24300IR89I0
    • 1SBL24300IR89IO
    • 1SBL24300IR89L0
    • 1SBL24300IR89LO
    • 1SBL24300IRB910
    • 1SBL24300IRB91O
    • 1SBL24300IRB9I0
    • 1SBL24300IRB9IO
    • 1SBL24300IRB9L0
    • 1SBL24300IRB9LO
    • 1SBL24300LR8910
    • 1SBL24300LR891O

    Numéros Annexées

    • 1SBL243001R8910-A
    • 1SBL243001R8910-B
    • 1SBL243001R8910-C
    • 1SBL243001R8910-D
    • 1SBL243001R8910-E
    • 1SBL243001R8910-F
    • 1SBL243001R8910-G
    • 1SBL243001R8910-H
    • 1SBL243001R8910-I
    • 1SBL243001R8910-J
    • 1SBL243001R8910-K
    • 1SBL243001R8910-L
    • 1SBL243001R8910-M
    • 1SBL243001R8910-N
    • 1SBL243001R8910-O
    • 1SBL243001R8910-P
    • 1SBL243001R8910-Q
    • 1SBL243001R8910-R
    • 1SBL243001R8910-S
    • 1SBL243001R8910-T
    • 1SBL243001R8910-U
    • 1SBL243001R8910-V
    • 1SBL243001R8910-W
    • 1SBL243001R8910-X
    • 1SBL243001R8910-Y
    • 1SBL243001R8910-Z

    Plus de Produits de ce Genre

    Customers Are Also Buying

    Livraison qui Répond à Vos Besoins

    Late West Coast Shipping Hours
    Livraison Rapide pour le Côte Ouest (17 heures, heure du Pacifique)
    Spécialistes de l’Expédition directe au détaillant et d’Envoi Aveugle
    Habilement Emballé Statique-limitée
    Service le Jour Même
    Courier Intra-Muros Nationale et Internationale
    visa credit card logo mastercard credit card logo discover credit card logo american express credit card logo