- Description: TAL16-30-01 90-150V DC Contactor
- Product ID: 1SBL183061R6601
- Extended Product Type: 1SBL183061R6601
- Product Net Weight: 0.520 kg
- Product Net Width: 44 mm
- Product Net Height: 78 mm
- Product Net Depth: 97 mm
- Degree of Protection: acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
- Ambient Air Temperature: Close to Contactor Fitted with Thermal O/L Relay -25 ... +55 C Close to Contactor for Storage -60 ... +80 C Close to Contactor without Thermal O/L Relay -40 ... +55 C
- Rated Impulse Withstand Voltage (U<sub>imp</sub>): 8 kV
- Rated Insulation Voltage (U<sub>i</sub>): acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V acc. to UL/CSA 600 V
- Terminal Type: Screw Terminals
- Rated Frequency (f): Supply Circuit 50 Hz Supply Circuit 60 Hz
- Number of Auxiliary Contacts NO: 0
- Number of Auxiliary Contacts NC: 1
- Mechanical Durability: 10 million
- Connecting Capacity Main Circuit: Flexible with Cable End 0.75 ... 2.5 mm Rigid Cable 1 ... 4 mm
- GOST Certificate: GOST_POCCFRME77B07175
- Maximum Operating Altitude Permissible: 3000 m
- Rated Control Circuit Voltage (U<sub>c</sub>): DC Operation 90 150 V
- Climatic Withstand: acc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II
- Maximum Mechanical Switching Frequency: 3600 cycles per hour
- Connecting Capacity Auxiliary Circuit: Flexible with Cable End 0.75 ... 2.5 mm Rigid Cable 1 ... 4 mm
- Operate Time: Between Coil Energization and NO Contact Closing 50 ... 100 ms Between Coil De-energization and NO Contact Opening 10 ... 17 ms Between Coil De-energization and NC Contact Closing 16 ... 27 ms Between Coil Energization and NC Contact Opening 20 ... 70 ms
- Number of Main Contacts NO: 3
- Number of Main Contacts NC: 0
- Short-Circuit Protective Devices: Auxiliary Circuit - gG Type Fuses 10 A gG Type Fuses 32 A
- Maximum Breaking Capacity: cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 250 A cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 100 A
- Coil Consumption: Holding DC (Umin / Umax) 2.5 / 8.5 W Pull-in DC (Umin / Umax) 2.5 / 8.5 W
- Connecting terminals (delivered in open position) Main poles: M 3.5 (+,-) pozidriv 2 screw with cable clamp
- EAN: 3471522316660
- Minimum Order Quantity: 1 piece
- Customs Tariff Number: 85369085
- Package Level 1 Width: 86 mm
- Package Level 1 Length: 141 mm
- Package Level 1 Height: 51 mm
- Package Level 1 Gross Weight: 0.52 kg
- Package Level 1 EAN: 3471522316660
- Package Level 2 Units: 28 piece
- Package Level 3 Units: 336 piece
- Package Level 1 Units: 1 piece
- Rated Operational Voltage: Auxiliary Circuit 690 V Main Circuit 690 V
- Conventional Free-air Thermal Current (I<sub>th</sub>): acc. to IEC 60947-4-1, Open Contactors q = 40 C 30 A acc. to IEC 60947-5-1, q = 40 C 16 A
- Rated Operational Current AC-1 (I<sub>e</sub>): (690 V) 40 C 30 A (690 V) 55 C 27 A (690 V) 70 C 23 A
- Rated Operational Current AC-3 (I<sub>e</sub>): (220 / 230 / 240 V) 55 C 17 A (380 / 400 V) 55 C 17 A (415 V) 55 C 17 A (440 V) 55 C 16 A (500 V) 55 C 14 A (690 V) 55 C 10 A
- Rated Operational Power AC-3 (P<sub>e</sub>): (220 / 230 / 240 V) 4 kW (380 / 400 V) 7.5 kW (415 V) 9 kW (440 V) 9 kW (500 V) 9 kW (690 V) 9 kW
- Rated Breaking Capacity AC-3 acc. to IEC 60947-4-1: 8 x Ie AC-3
- Rated Making Capacity AC-3 acc. to IEC 60947-4-1: 10 x Ie AC-3
- Rated Operational Current AC-15 (I<sub>e</sub>): (220 / 240 V) 4 A (24 / 127 V) 6 A (380 / 440 V) 3 A (500 V) 2 A (690 V) 2 A
- Rated Short-time Withstand Current (I<sub>cw</sub>): at 40 C Ambient Temp, in Free Air, from a Cold State 10 s 140 A at 40 C Ambient Temp, in Free Air, from a Cold State 15 min 30 A at 40 C Ambient Temp, in Free Air, from a Cold State 1 min 60 A at 40 C Ambient Temp, in Free Air, from a Cold State 1 s 300 A at 40 C Ambient Temp, in Free Air, from a Cold State 30 s 80 A for 0.1 s 140 A for 1 s 100 A
- Maximum Electrical Switching Frequency: AC-1 600 cycles per hour AC-2 / AC-4 300 cycles per hour AC-3 1200 cycles per hour
- Rated Operational Current DC-13 (I<sub>e</sub>): (125 V) 1.1 / 138 A (24 V) 6 / 144 A (250 V) 0.55 / 138 A (48 V) 2.8 / 134 A (72 V) 2 / 144 A
- Resistance to Shock acc. to IEC 60068-2-27: Closed, Shock Direction: A 20 g Open, Shock Direction: A 10 g Closed, Shock Direction: B1 15 g Open, Shock Direction: B1 5 g Shock Direction: B2 10 g Closed, Shock Direction: C1 20 g Open, Shock Direction: C1 8 g Closed, Shock Direction: C2 14 g Open, Shock Direction: C2 8 g
- RoHS Status: Following EU Directive 2002/95/EC August 18, 2005 and amendment
- Instructions and Manuals: 1SBC101003M5501
- CB Certificate: CB_FR3450-60022335-515371C
- CCC Certificate: CCC_2004010304138320
- CSA Certificate: CSA_1041746
- cUL Certificate: UL_20160205-E312527-10-2
- Data Sheet, Technical Information: 1SNC001003C0202
- Declaration of Conformity - CE: 1SBD250804U1000
- EAC Certificate: EAC_RU C-FR ME77 B01010
- RoHS Information: 1SBD350051R1000
- UL Listing Card: UL_E312527
- ETIM 4: EC000066 - Magnet contactor, AC-switching
- ETIM 5: EC000066 - Magnet contactor, AC-switching
- ETIM 6: EC000066 - Power contactor, AC switching
- UNSPSC: 39121529
- Object Classification Code: Q
Santa Clara Systems specializes in hard-to-find parts. Choose from our overstock inventory and save on TAL16-30-01-66 . Santa Clara Systems carries 36,682 items from ABB.
- 1 Built-In Auxiliary Contact
- Front And Side-Mounted Add-On Auxiliary Contact Blocks - Control Circuit: Dc Operated With Solid Core Magnet Circuit. The Polarity On The Coil Terminals (A1+ And A2-) Must Be Respected - Accessories: A Wide Range Of Accessories Is Available. Tal... Contactors Are Fitted With Low Consumption Dc Coils And Offer A Large Coil Voltage Range.
- Tal16 Contactors Are Mainly Used For Controlling 3-Phase Motors And Generally For Controlling Power Circuits Up To 690 V Ac Or 220 V Dc. The Contactors Can Also Be Used For Many Other Applications Such As Isolation
- Capacitor Switching
- Lighting. The Tal... Series 1-Stack 3-Pole Contactors Are Of The Block Type Design. - Main Poles And Auxiliary Contact Blocks: 3 Main Poles
Alternates
- 1SBL183061R6601
- TAL16 30 01 66
- TAL16300166
Common Typos
- TAL16-30-01-6G
- TAL16-30-01-G6
- TAL16-30-01-GG
- TAL16-30-0I-66
- TAL16-30-0I-6G
- TAL16-30-0I-G6
- TAL16-30-0I-GG
- TAL16-30-0L-66
- TAL16-30-0L-6G
- TAL16-30-0L-G6
- TAL16-30-0L-GG
- TAL16-30-O1-66
- TAL16-30-O1-6G
- TAL16-30-O1-G6
- TAL16-30-O1-GG
- TAL16-30-OI-66
- TAL16-30-OI-6G
- TAL16-30-OI-G6
- TAL16-30-OI-GG
- TAL16-30-OL-66
- TAL16-30-OL-6G
- TAL16-30-OL-G6
- TAL16-30-OL-GG
- TAL16-3O-01-66
- TAL16-3O-01-6G
- TAL16-3O-01-G6
Appended Numbers
- TAL16-30-01-66-A
- TAL16-30-01-66-B
- TAL16-30-01-66-C
- TAL16-30-01-66-D
- TAL16-30-01-66-E
- TAL16-30-01-66-F
- TAL16-30-01-66-G
- TAL16-30-01-66-H
- TAL16-30-01-66-I
- TAL16-30-01-66-J
- TAL16-30-01-66-K
- TAL16-30-01-66-L
- TAL16-30-01-66-M
- TAL16-30-01-66-N
- TAL16-30-01-66-O
- TAL16-30-01-66-P
- TAL16-30-01-66-Q
- TAL16-30-01-66-R
- TAL16-30-01-66-S
- TAL16-30-01-66-T
- TAL16-30-01-66-U
- TAL16-30-01-66-V
- TAL16-30-01-66-W
- TAL16-30-01-66-X
- TAL16-30-01-66-Y
- TAL16-30-01-66-Z