• ABB MS497-90 Manual Motor Starter | MS497-90 Product Image
  • Abb MS497-90 Barcode

MS497-90

Let Us Find It

Current response time:

18 Minutes 9 Seconds
  • Description: Manual Motor Starter | MS497-90
  • Product ID: 1SAM580000R1009
  • Extended Product Type: 1SAM580000R1009
  • Product Net Weight: 2.268 kg
  • Product Net Width: 70 mm
  • Product Net Height: 165 mm
  • Product Net Depth: 174 mm
  • Degree of Protection: Housing IP20 Main Circuit Terminals IP00
  • Ambient Air Temperature: Operation -20 ... +70 C Operation Compensated -20 ... +60 C Storage -50 ... +80 C
  • Standards: IEC/EN 60947-1 IEC/EN 60947-2 IEC/EN 60947-4-1 UL 508 CSA 22.2 No. 14
  • Rated Impulse Withstand Voltage (U<sub>imp</sub>): Main Circuit 6 kV
  • Rated Insulation Voltage (U<sub>i</sub>): 690 V
  • Number of Poles: 3
  • Rated Frequency (f): Main Circuit 50 Hz Main Circuit 60 Hz
  • Power Loss: at Rated Operating Conditions per Pole 6.1 10 W
  • Mounting on DIN Rail: TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
  • eClass: 7.0 27370401
  • Tightening Torque: Main Circuit 4 ... 6 N&#183;m
  • Actuator Type: Rotary Handle
  • Mounting Position: Position 1 to 6
  • Mechanical Durability: 50000 cycle
  • Connecting Capacity Main Circuit: Flexible with Ferrule 1x 2.5 ... 50 mm Flexible with Ferrule 2x 2.5 ... 35 mm Solid 1/2x 2.5 ... 16 mm Stranded 1x 10 ... 70 mm Stranded 2x 10 ... 50 mm
  • GOST Certificate: 1SAA963001-2702
  • Maximum Operating Voltage UL/CSA: Main Circuit 600 V AC
  • Contact Position Indication: ON / OFF / TRIP
  • Maximum Operating Altitude Permissible: 2000 m
  • Tightening Torque UL/CSA: Main Circuit 35 ... 53 in&#183;lb
  • Wire Stripping Length: Main Circuit 17 mm
  • GL Certificate: 1SAA937000-0404
  • Connecting Capacity Main Circuit UL/CSA: Flexible 1x 10-2/0 AWG Flexible 1/2x 10-1/0 AWG Stranded 1x 10-2/0 AWG Stranded 1/2x 10-1/0 AWG
  • Ampere Rating UL/CSA: 90 A
  • Horsepower Rating UL/CSA: (200 V AC) Three Phase 30 Hp (208 V AC) Three Phase 30 Hp (220 ... 240 V AC) Three Phase 30 Hp (440 ... 480 V AC) Three Phase 75 Hp (550 ... 600 V AC) Three Phase 100 Hp
  • General Use Rating UL/CSA: (600 V AC) 90 A
  • Electrical Durability: 25000 cycle
  • EAN: 4013614265655
  • Minimum Order Quantity: 1 piece
  • Customs Tariff Number: 85362010
  • Package Level 1 Width: 76.5 mm
  • Package Level 1 Length: 190 mm
  • Package Level 1 Height: 171 mm
  • Package Level 1 Gross Weight: 2.26 kg
  • Package Level 1 Units: 1 piece
  • Rated Ultimate Short-Circuit Breaking Capacity (I<sub>cu</sub>): (230 V AC) 100 kA (400 V AC) 100 kA (440 V AC) 70 kA (500 V AC) 10 kA (690 V AC) 10 kA
  • Rated Instantaneous Short-Circuit Current Setting (I<sub>i</sub>): 1170 A
  • Setting Range: 70 ... 90 A
  • Rated Operational Power AC-3 (P<sub>e</sub>): (400 V) Three Phase 45 kW
  • Rated Operational Voltage: Main Circuit 690 V AC Main Circuit 450 V DC
  • Rated Operational Current (I<sub>e</sub>): 90 A
  • Rated Operational Current AC-3 (I<sub>e</sub>): 90 A
  • Conventional Free-air Thermal Current (I<sub>th</sub>): Main Circuit 90 A
  • Pollution Degree: 3
  • Recommended Screw Driver: Hexagon 4
  • Rated Service Short-Circuit Breaking Capacity (I<sub>cs</sub>): (230 V AC) 100 kA (400 V AC) 50 kA (440 V AC) 50 kA (500 V AC) 5 kA (690 V AC) 3 kA
  • Ambient Air Temperature Compensation: Yes
  • Resistance to Shock acc. to IEC 60068-2-27: 11 ms Pulse 25g
  • RoHS Status: Following EU Directive 2002/95/EC August 18, 2005 and amendment
  • Data Sheet, Technical Information (Part 2): 1SAM500503F0009
  • Data Sheet, Technical Information (Part 3): 9AKK105713A1104
  • Instructions and Manuals: 1SAM507001R1001
  • Instructions and Manuals (Part 2): 2CDC131017M5701
  • ATEX Certificate: 1SAA937000-3901
  • BV Certificate: 1SAA937000-0202
  • CCC Certificate: 1SAA937001-3803
  • cUL Certificate: cUL_E195536
  • Data Sheet, Technical Information: 1SBC100173C0201
  • Declaration of Conformity - CE: 1SAD938505-0050
  • DNV Certificate: 1SAA937000-0301
  • EAC Certificate: 1SAA937001-2703
  • LR Certificate: 1SAA937000-0504
  • RMRS Certificate: 1SAA918000-0703
  • RoHS Information: 1SAA918002-4401
  • UL Certificate: UL_E167205 UL_E195536
  • ETIM 4: EC000074 - Motor protective circuit-breaker
  • ETIM 5: EC000074 - Motor protective circuit-breaker
  • ETIM 6: EC000074 - Motor protection circuit-breaker
  • UNSPSC: 39121521
  • Object Classification Code: F
Santa Clara Systems specializes in hard-to-find parts. Choose from our overstock inventory and save on MS497-90 . Santa Clara Systems carries 36,673 items from ABB.
We are in the process of adding data and downloadable material for this item. Please search similar items for more information related to this product.

Alternates

  • 1SAM580000R1009
  • MS497 90
  • MS49790

Common Typos

  • M5497-90
  • M5497-9O
  • MS497-9O

Appended Numbers

  • MS497-90-A
  • MS497-90-B
  • MS497-90-C
  • MS497-90-D
  • MS497-90-E
  • MS497-90-F
  • MS497-90-G
  • MS497-90-H
  • MS497-90-I
  • MS497-90-J
  • MS497-90-K
  • MS497-90-L
  • MS497-90-M
  • MS497-90-N
  • MS497-90-O
  • MS497-90-P
  • MS497-90-Q
  • MS497-90-R
  • MS497-90-S
  • MS497-90-T
  • MS497-90-U
  • MS497-90-V
  • MS497-90-W
  • MS497-90-X
  • MS497-90-Y
  • MS497-90-Z

Customers Are Also Buying

We Deliver!

Late West Coast Shipping Hours
Late West Coast Shipping (5PM PST)
Drop-Ship and Blind-Ship Specialists
Expertly Packed Static-Limited
Same-Day Service
In-House Courier
visa credit card logo mastercard credit card logo discover credit card logo american express credit card logo

Customers we work with

3M logo
Kaiser Permanente logo
Safeway Logo
Georgia-Pacific logo
Coca Cola logo
duke energy logo
BART logo
Pepsi logo
LA DWP logo
US Navy logo
Dean Foods logo
ConAgra Brands logo