- Description: module XPSAR - Emergency stop - 115 V AC
- Product weight: 0.88 lb(US) (0.4 kg)
- Range of product: Preventa Safety automation
- IP degree of protection: IP20 (terminals) conforming to EN/IEC 60529, IP40 (enclosure) conforming to EN/IEC 60529
- Standards: EN 1088/ISO 14119, EN/IEC 60204-1, EN/IEC 60947-5-1, EN/ISO 13850
- [Ui] rated insulation voltage: 300 V (degree of pollution: 2) conforming to DIN VDE 0110 part 1, 300 V (degree of pollution: 2) conforming to IEC 60947-5-1
- [Uimp] rated impulse withstand voltage: 4 kV overvoltage category III conforming to IEC 60947-5-1, 4 kV overvoltage category III conforming to DIN VDE 0110 part 1
- Connections - terminals: Captive screw clamp terminals, removable terminal block, clamping capacity: 2 x 0.5...2 x 1.5 mm flexible cable with cable end, with double bezel, Captive screw clamp terminals, removable terminal block, clamping capacity: 1 x 0.2...1 x 2.5 mm flexible cable with cable end, with double bezel, Captive screw clamp terminals, removable terminal block, clamping capacity: 1 x 0.2...1 x 2.5 mm solid cable with cable end, with double bezel, Captive screw clamp terminals, removable terminal block, clamping capacity: 1 x 0.25...1 x 2.5 mm flexible cable with cable end, with double bezel, Captive screw clamp terminals, removable terminal block, clamping capacity: 2 x 0.2...2 x 1 mm solid cable with cable end, with double bezel, Captive screw clamp terminals, removable terminal block, clamping capacity: 2 x 0.2...2 x 1.5 mm flexible cable with cable end, with double bezel, Captive screw clamp terminals, removable terminal block, clamping capacity: 2 x 0.25...2 x 1 mm flexible cable with cable end, with double bezel
- Mounting support: 35 mm symmetrical DIN rail
- [Ith] conventional free air thermal current: 40 A
- [Uc] control circuit voltage: 24 V DC
- [Us] rated supply voltage: 115 V AC (- 15...15 %), 24 V DC (- 15...10 %)
- Associated fuse rating: 10 A fuse type fast blow for relay output conforming to EN/IEC 60947-5-1, DIN VDE 0660 part 200, 6 A fuse type gG or gL for relay output conforming to EN/IEC 60947-5-1, DIN VDE 0660 part 200
- Breaking capacity: 20 mA at 24 V, 2 A at 24 V (DC-13) time constant: 50 ms for relay output
- Output type: Relay instantaneous opening 7 NO, volt-free
- Synchronisation time between inputs: 100 ms
- Product or component type: Preventa safety module
- Supply frequency: 50/60 Hz
- Product certifications: CSA, TV, UL
- Safety module name: XPSAR
- power consumption in W: <= 4 W DC
- Safety module application: For emergency stop, switch and safety light curtain monitoring
- power consumption in VA: <= 9 VA AC
- Ambient air temperature for operation: 14...131 F (-10...55 C)
- Function of module: Monitoring of electro-sensitive protection equipment (ESPE), Monitoring of a movable guard associated with 2 switches and automatic start, Monitoring of a movable guard, Emergency stop monitoring 1-channel wiring, Emergency stop with 2 NC contacts monitoring 2-channel wiring, Multiple emergency stop monitoring 2-channel wiring
- Input protection type: Internal, electronic
- Ambient air temperature for storage: -13...185 F (-25...85 C)
- Safety level: Can reach PL e/category 4 conforming to EN/ISO 13849-1, Can reach SILCL 3 conforming to EN/IEC 62061
- Safety reliability data: DC > 99 % conforming to EN/ISO 13849-1, MTTFd = 277.8 years conforming to EN/ISO 13849-1, PFHd = 2.22E-9 1/h conforming to EN/IEC 62061
- Line resistance: 50 Ohm
- Type of start: Configurable
- Output thermal current: 10 A per relay relay output
- Number of additional circuits: 2 NC + 4 solid state outputs
- Minimum output current: 170 mA for relay output
- Minimum output voltage: 17 V relay output
- Response time on input open: <= 20 ms
- Local signalling: 4 LEDs
- Current consumption: 30 mA at 24 V DC (on power supply)
Santa Clara Systems specializes in hard-to-find parts. Choose from our overstock inventory and save on XPSAR351144P . Santa Clara Systems carries 10,298 items from Telemecanique.
- Module Xpsar - Emergency Stop - 115 V Ac
Alternates
Common Typos
- XP5AR351144P
- XP5AR351I44P
- XP5AR351L44P
- XP5AR35I144P
- XP5AR35II44P
- XP5AR35IL44P
- XP5AR35L144P
- XP5AR35LI44P
- XP5AR35LL44P
- XPSAR351I44P
- XPSAR351L44P
- XPSAR35I144P
- XPSAR35II44P
- XPSAR35IL44P
- XPSAR35L144P
- XPSAR35LI44P
- XPSAR35LL44P
- XPSAR3S1144P
- XPSAR3S1I44P
- XPSAR3S1L44P
- XPSAR3SI144P
- XPSAR3SII44P
- XPSAR3SIL44P
- XPSAR3SL144P
- XPSAR3SLI44P
- XPSAR3SLL44P
Appended Numbers
- XPSAR351144P-A
- XPSAR351144P-B
- XPSAR351144P-C
- XPSAR351144P-D
- XPSAR351144P-E
- XPSAR351144P-F
- XPSAR351144P-G
- XPSAR351144P-H
- XPSAR351144P-I
- XPSAR351144P-J
- XPSAR351144P-K
- XPSAR351144P-L
- XPSAR351144P-M
- XPSAR351144P-N
- XPSAR351144P-O
- XPSAR351144P-P
- XPSAR351144P-Q
- XPSAR351144P-R
- XPSAR351144P-S
- XPSAR351144P-T
- XPSAR351144P-U
- XPSAR351144P-V
- XPSAR351144P-W
- XPSAR351144P-X
- XPSAR351144P-Y
- XPSAR351144P-Z
We Deliver!
- ✓ Late West Coast Shipping (5PM PST)
- ✓ Drop-Ship and Blind-Ship Specialists
- ✓ Expertly Packed Static-Limited
- ✓ Same-Day Service
- ✓ In-House Courier