• ABB AS12-30-01-26M AS12-30-01-26M 230V50/60HZ Contactor Product Image
  • Abb AS12-30-01-26M Barcode

AS12-30-01-26M

Let Us Find It

Current response time:

By 5AM PT on Tuesday
  • Description: AS12-30-01-26M 230V50/60HZ Contactor
  • Product ID: 1SBL111001M2601
  • Extended Product Type: 1SBL111001M2601
  • Product Net Weight: 0.220 kg
  • Product Net Width: 45 mm
  • Product Net Height: 68 mm
  • Product Net Depth: 72.5 mm
  • Degree of Protection: acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20 acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20
  • Ambient Air Temperature: Close to Contactor for Storage -60 ... +80 C Close to Contactor Fitted with Thermal O/L Relay -25 ... +60 C Close to Contactor without Thermal O/L Relay -40 ... +70 C
  • Standards: IEC 60947-1 / 60947-4-1 and EN 60947-1 / 60947-4-1, UL 508, CSA C22.2 N14
  • Rated Impulse Withstand Voltage (U<sub>imp</sub>): 6 kV
  • Rated Insulation Voltage (U<sub>i</sub>): acc. to UL/CSA 600 V acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V acc. to IEC 60947-5-1 and VDE 0110 (Gr. C) 690 V
  • Terminal Type: Screw Terminals
  • Rated Frequency (f): Auxiliary Circuit 50 / 60 Hz Main Circuit 50 / 60 Hz
  • Number of Auxiliary Contacts NO: 0
  • Number of Auxiliary Contacts NC: 1
  • Connecting Capacity Main Circuit: Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm Flexible with Ferrule 1/2x 0.75 ... 2.5 mm Rigid 1/2x 0.75 ... 4 mm
  • GOST Certificate: GOST_POCCCNME77B07822.pdf
  • Maximum Operating Altitude Permissible: 3000 m
  • Rated Control Circuit Voltage (U<sub>c</sub>): 50 Hz 230 V 60 Hz 230 V
  • Climatic Withstand: Category B according to IEC 60947-1 Annex Q
  • Tightening Torque UL/CSA: Auxiliary Circuit 9 in&#183;lb Control Circuit 9 in&#183;lb Main Circuit 9 in&#183;lb
  • Maximum Mechanical Switching Frequency: 3600 cycles per hour
  • Connecting Capacity Auxiliary Circuit: Flexible with Ferrule 1/2x 0.75 ... 2.5 mm Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm Rigid 1/2x 0.75 ... 2.5 mm
  • Operate Time: Between Coil De-energization and NC Contact Closing 7 ... 22 ms Between Coil De-energization and NO Contact Opening 5 ... 19 ms Between Coil Energization and NC Contact Opening 6 ... 18 ms Between Coil Energization and NO Contact Closing 9 ... 24 ms
  • Wire Stripping Length: Auxiliary Circuit 9 mm Control Circuit 9 mm Main Circuit 9 mm
  • Number of Main Contacts NO: 3
  • Number of Main Contacts NC: 0
  • Maximum Breaking Capacity: cos phi=0.45 (cos phi=0.35 for Ie &gt; 100 A) at 440 V 155 A cos phi=0.45 (cos phi=0.35 for Ie &gt; 100 A) at 690 V 90 A
  • Connecting Capacity Control Circuit: Flexible with Ferrule 1/2x 0.75 ... 2.5 mm Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm Rigid 1/2x 0.75 ... 2.5 mm
  • Horsepower Rating UL/CSA: (120 V AC) Single Phase 1/2 Hp (240 V AC) Single Phase 1.5 Hp (200 ... 208 V AC) Three Phase 2 Hp (220 ... 240 V AC) Three Phase 3 Hp (440 ... 480 V AC) Three Phase 7.5 Hp (550 ... 600 V AC) Three Phase 10 Hp
  • General Use Rating UL/CSA: (600 V AC) 20 A
  • EAN: 3471523047266
  • Minimum Order Quantity: 40 piece
  • Customs Tariff Number: 85369085
  • Package Level 1 Width: 293 mm
  • Package Level 1 Length: 167 mm
  • Package Level 1 Height: 250 mm
  • Package Level 1 Gross Weight: 8.8 kg
  • Package Level 1 EAN: 3471523047266
  • Package Level 3 Units: 960 piece
  • Package Level 1 Units: 40 piece
  • Rated Operational Voltage: Auxiliary Circuit 690 V Main Circuit 690 V
  • Conventional Free-air Thermal Current (I<sub>th</sub>): acc. to IEC 60947-4-1, Open Contactors q = 40 C 25 A acc. to IEC 60947-5-1, q = 40 C 10 A
  • Rated Operational Current AC-1 (I<sub>e</sub>): (690 V) 40 C 24 A (690 V) 60 C 20 A (690 V) 70 C 16 A
  • Rated Operational Current AC-3 (I<sub>e</sub>): (220 / 230 / 240 V) 60 C 12 A (380 / 400 V) 60 C 12 A (415 V) 60 C 12 A (440 V) 60 C 11 A (500 V) 60 C 11 A (690 V) 60 C 7 A
  • Rated Operational Power AC-3 (P<sub>e</sub>): (220 / 230 / 240 V) 3 kW (400 V) 5.5 kW (415 V) 5.5 kW (440 V) 5.5 kW (500 V) 5.5 kW (690 V) 5.5 kW
  • Rated Operational Current AC-15 (I<sub>e</sub>): (220 / 240 V) 4 A (24 / 127 V) 6 A (400 / 440 V) 3 A (500 V) 2 A (690 V) 2 A
  • Rated Short-time Withstand Current (I<sub>cw</sub>): at 40 C Ambient Temp, in Free Air, from a Cold State 10 s 124 A at 40 C Ambient Temp, in Free Air, from a Cold State 15 min 24 A at 40 C Ambient Temp, in Free Air, from a Cold State 1 min 55 A at 40 C Ambient Temp, in Free Air, from a Cold State 1 s 250 A at 40 C Ambient Temp, in Free Air, from a Cold State 30 s 75 A for 0.1 s 140 A for 1 s 100 A
  • Maximum Electrical Switching Frequency: AC-1 600 cycles per hour AC-15 1200 cycles per hour AC-2 / AC-4 300 cycles per hour AC-3 1200 cycles per hour DC-13 900 cycles per hour
  • Rated Operational Current DC-13 (I<sub>e</sub>): (110 V) 0.55 A / 60 W (125 V) 0.55 A / 69 W (220 V) 0.27 A / 60 W (24 V) 6 A / 144 W (250 V) 0.27 A / 68 W (48 V) 2.8 A / 134 W (72 V) 1 A / 72 W
  • Resistance to Vibrations acc. to IEC 60068-2-6: 5 ... 300 Hz 3 g Closed position / 2 g Open position
  • Resistance to Shock acc. to IEC 60068-2-27: Closed, Shock Direction: B1 10 g Closed, Shock Direction: C1 20 g Closed, Shock Direction: C2 20 g Open, Shock Direction: B1 5 g Open, Shock Direction: C1 9 g Open, Shock Direction: C2 14 g Shock Direction: A 20 g Shock Direction: B2 15 g
  • RoHS Status: Planned to follow EU Directive 2002/95/EC August 18, 2005 and amendment after 2009 Q4
  • Instructions and Manuals: 1SBC101020M9701
  • CB Certificate: CB_CN13475-M1
  • CCC Certificate: CCC_2007010309251577
  • cUL Certificate: UL_20110325-E312527
  • Data Sheet, Technical Information: 1SBC100173C0201
  • Declaration of Conformity - CE: 1SBD250014U1000
  • RoHS Information: 1SBD251000E1001
  • UL Listing Card: NOA_E312527.pdf
  • ETIM 4: EC000066 - Magnet contactor, AC-switching
  • ETIM 5: EC000066 - Magnet contactor, AC-switching
  • ETIM 6: EC000066 - Power contactor, AC switching
  • UNSPSC: 39121529
  • Object Classification Code: Q
Santa Clara Systems specializes in hard-to-find parts. Choose from our overstock inventory and save on AS12-30-01-26M . Santa Clara Systems carries 36,673 items from ABB.
  • Front-Mounted Add-On Auxiliary Contact Blocks (Mechanically-Linked Auxiliary Contacts Compliant With Annex L Of Iec 60947-5-1. N.c. Mirror Contacts Compliant With Annex F Of Iec 60947-4-1) - Control Circuit: Ac Operated With Laminated Magnet Circuit - Accessories: A Wide Range Of Accessories Is Available.
  • As12 Contactors Are Mainly Used For Controlling 3-Phase Motors And Generally For Controlling Power Circuits Up To 690 V Ac Or 220 V Dc. They Are Mainly Used For Controlling 3-Phase Motors
  • Non-Inductive Or Slightly Inductive Loads. The As... Series 1-Stack 3-Pole Contactors Are Of The Block Type Design. - Main Poles And Auxiliary Contact Blocks: 3 Main Poles
  • 1 Built-In Auxiliary Contact

Alternates

  • 1SBL111001M2601
  • AS12 30 01 26M
  • AS12300126M

Common Typos

  • AS12-30-01-2GM
  • AS12-30-01-Z6M
  • AS12-30-01-ZGM
  • AS12-30-0I-26M
  • AS12-30-0I-2GM
  • AS12-30-0I-Z6M
  • AS12-30-0I-ZGM
  • AS12-30-0L-26M
  • AS12-30-0L-2GM
  • AS12-30-0L-Z6M
  • AS12-30-0L-ZGM
  • AS12-30-O1-26M
  • AS12-30-O1-2GM
  • AS12-30-O1-Z6M
  • AS12-30-O1-ZGM
  • AS12-30-OI-26M
  • AS12-30-OI-2GM
  • AS12-30-OI-Z6M
  • AS12-30-OI-ZGM
  • AS12-30-OL-26M
  • AS12-30-OL-2GM
  • AS12-30-OL-Z6M
  • AS12-30-OL-ZGM
  • AS12-3O-01-26M
  • AS12-3O-01-2GM
  • AS12-3O-01-Z6M

Appended Numbers

  • AS12-30-01-26M-A
  • AS12-30-01-26M-B
  • AS12-30-01-26M-C
  • AS12-30-01-26M-D
  • AS12-30-01-26M-E
  • AS12-30-01-26M-F
  • AS12-30-01-26M-G
  • AS12-30-01-26M-H
  • AS12-30-01-26M-I
  • AS12-30-01-26M-J
  • AS12-30-01-26M-K
  • AS12-30-01-26M-L
  • AS12-30-01-26M-M
  • AS12-30-01-26M-N
  • AS12-30-01-26M-O
  • AS12-30-01-26M-P
  • AS12-30-01-26M-Q
  • AS12-30-01-26M-R
  • AS12-30-01-26M-S
  • AS12-30-01-26M-T
  • AS12-30-01-26M-U
  • AS12-30-01-26M-V
  • AS12-30-01-26M-W
  • AS12-30-01-26M-X
  • AS12-30-01-26M-Y
  • AS12-30-01-26M-Z

More Products Like This

Customers Are Also Buying

We Deliver!

Late West Coast Shipping Hours
Late West Coast Shipping (5PM PST)
Drop-Ship and Blind-Ship Specialists
Expertly Packed Static-Limited
Same-Day Service
In-House Courier
visa credit card logo mastercard credit card logo discover credit card logo american express credit card logo

Customers we work with

3M logo
Kaiser Permanente logo
Safeway Logo
Georgia-Pacific logo
Coca Cola logo
duke energy logo
BART logo
Pepsi logo
LA DWP logo
US Navy logo
Dean Foods logo
ConAgra Brands logo