- Beschreibung: AF116-40-22B-11 Contactor
- Rated Short-time Withstand Current (Icw): at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 928 A at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 536 A at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 160 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1300 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 379 A
- Maximum Breaking Capacity: cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 2000 A
- Maximum Electrical Switching Frequency: AC-1 300 cycles per hour
- Rated Insulation Voltage (Ui): acc. to UL/CSA 600 V acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V
- Rated Impulse Withstand Voltage (Uimp): Main Circuit 8 kV
- Mechanical Durability: 5 million
- Maximum Mechanical Switching Frequency: 300 cycles per hour
- Coil Operating Limits: (acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at ? ? 70 °C) °C
- Rated Control Circuit Voltage (Uc): 60 Hz 2460 V 50 Hz 2460 V DC Operation 2060 V
- Coil Consumption: Pull-in at Max. Rated Control Circuit Voltage 60 Hz 225 V·A Holding at Max. Rated Control Circuit Voltage DC 2.5 W Holding at Max. Rated Control Circuit Voltage 50 Hz 5.5 V·A Pull-in at Max. Rated Control Circuit Voltage DC 210 W Pull-in at Max. Rated Control Circuit Voltage 50 Hz 225 V·A Holding at Max. Rated Control Circuit Voltage 60 Hz 5.5 V·A
- Operate Time: Between Coil Energization and NO Contact Closing 2055 ms Between Coil De-energization and NO Contact Opening 4070 ms
- Connecting Capacity Main Circuit: Flexible 1x1070 mm² Rigid Cu-Cable 2x1095 mm²
- Connecting Capacity Auxiliary Circuit: Solid 1x14 mm² Flexible with Insulated Ferrule 1x0.752.5 mm² Stranded 1x14 mm² Flexible 1x0.752.5 mm² Flexible with Ferrule 2x0.752.5 mm²
- Degree of Protection: acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
- Terminal Type: Main Circuit: Bars
- Number of Main Contacts NO: 4
- Maximum Operating Altitude Permissible: 3000 m
- Ambient Air Temperature: Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25+50 °C Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40+70 °C Close to Contactor for Storage -40+70 °C
- Maximum Operating Voltage UL/CSA: Main Circuit 600 V
- ETIM 4: EC000066 - Magnet contactor, AC-switching
- ETIM 5: EC000066 - Magnet contactor, AC-switching
- Object Classification Code: Q
- Extended Product Type: AF116-40-22B-11
- Product ID: 1SFL427102R1122
- EAN: 7320500503881
- Minimum Order Quantity: 1 piece
- Customs Tariff Number: 85364900
- EAN: 7320500503881
- Product Net Depth: 128,1 mm
- Product Net Height: 150 mm
- Product Net Weight: 1.99 kg
- Product Net Width: 120 mm
- Package Level 1 Gross Weight: 2.19 kg
- Package Level 1 Units: 1 piece
- Number of Main Contacts NC: 0
- Number of Auxiliary Contacts NO: 2
- Number of Auxiliary Contacts NC: 2
- Rated Operational Voltage: Main Circuit 690 V
- Rated Frequency (f): Main Circuit 60 Hz
- Conventional Free-air Thermal Current (Ith): acc. to IEC 60947-4-1, Open Contactors q = 40 °C 160 A
- Rated Operational Current AC-1 (Ie): (690 V) 40 °C 160 A (690 V) 70 °C 130 A (690 V) 60 °C 145 A
- Rated Operational Current AC-3 (Ie): (220 / 230 / 240 V) 55 °C 116 A (415 V) 55 °C 116 A (440 V) 55 °C 116 A (380 / 400 V) 55 °C 116 A
- Rated Operational Power AC-3 (Pe): (220 / 230 / 240 V) 30 kW (380 / 400 V) 55 kW (440 V) 75 kW (415 V) 55 kW
- Rated Breaking Capacity AC-3 acc. to IEC 60947-4-1: 8 x Ie AC-3
- Rated Making Capacity AC-3 acc. to IEC 60947-4-1: 10 x Ie AC-3
- Short-Circuit Protective Devices: gG Type Fuses 200 A
Santa Clara Systems ist spezialisiert auf schwierig auffindbare Artikel. Wählen Sie aus unseren Lagerüberschüssen und sparen Sie 1SFL427102R1122 . Santa Clara Systems führt 36,195 Artikel von ABB.
- 50 And 60 Hz
- 20-60 V Dc
Alternativen
- AF116-40-22B-11
- AF116 40 22B 11
- AF1164022B11
Übliche Fehler
- 1SFL427102R112Z
- 1SFL427102R11Z2
- 1SFL427102R11ZZ
- 1SFL427102R1I22
- 1SFL427102R1I2Z
- 1SFL427102R1IZ2
- 1SFL427102R1IZZ
- 1SFL427102R1L22
- 1SFL427102R1L2Z
- 1SFL427102R1LZ2
- 1SFL427102R1LZZ
- 1SFL427102RI122
- 1SFL427102RI12Z
- 1SFL427102RI1Z2
- 1SFL427102RI1ZZ
- 1SFL427102RII22
- 1SFL427102RII2Z
- 1SFL427102RIIZ2
- 1SFL427102RIIZZ
- 1SFL427102RIL22
- 1SFL427102RIL2Z
- 1SFL427102RILZ2
- 1SFL427102RILZZ
- 1SFL427102RL122
- 1SFL427102RL12Z
angehängte Zahlen
- 1SFL427102R1122-A
- 1SFL427102R1122-B
- 1SFL427102R1122-C
- 1SFL427102R1122-D
- 1SFL427102R1122-E
- 1SFL427102R1122-F
- 1SFL427102R1122-G
- 1SFL427102R1122-H
- 1SFL427102R1122-I
- 1SFL427102R1122-J
- 1SFL427102R1122-K
- 1SFL427102R1122-L
- 1SFL427102R1122-M
- 1SFL427102R1122-N
- 1SFL427102R1122-O
- 1SFL427102R1122-P
- 1SFL427102R1122-Q
- 1SFL427102R1122-R
- 1SFL427102R1122-S
- 1SFL427102R1122-T
- 1SFL427102R1122-U
- 1SFL427102R1122-V
- 1SFL427102R1122-W
- 1SFL427102R1122-X
- 1SFL427102R1122-Y
- 1SFL427102R1122-Z
Mehr Produkte wie dieses
-
1SFL427102R1100
ABB
-
1SFL427102R1200
ABB
-
1SFL427102R1222
ABB
-
1SFL427102R1300
ABB
Customers Are Also Buying
-
700S-CF620EJC
Allen Bradley
-
440K-C21061
Allen Bradley
-
LS-17500 (BATTERY)
SAFT
-
800F-ALP
Allen Bradley
Lieferung die auf Ihre Bedürfnisse zugeschnitten sind.

- ✓ Späte Westküstenlieferung (17 Uhr Pazifik)
- ✓ Spezialist für Direktlieferungen and anonyme Lieferungen
- ✓ Fachmännisch verpackt Statisch limitiert
- ✓ Same-Day Service
- ✓ Hausinterner Kurier Domestic and International