- Description: Contactor | 1SBL181201R8000
 - Product ID: 1SBL181201R8000
 - Extended Product Type: 1SBL181201R8000
 - Product Net Weight: 0.340 kg
 - Product Net Width: 44 mm
 - Product Net Height: 74 mm
 - Product Net Depth: 74 mm
 - Degree of Protection: acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
 - Ambient Air Temperature: Near Contactor for Operation in Free Air (0.85 ... 1.1 Uc) -40 ... +55 °C Near Contactor for Operation in Free Air (Uc) -40 ... +70 °C Close to Contactor for Storage -60 ... +80 °C
 - Standards: Devices complying with international standards IEC 947-1 / 947-4-1, and European standards EN 60 947-1 / 60 947-4-1. Electromagnetic compatibility (EMC) acc. to amendment A11 to IEC 947-1; EN 60 947-1 and amendment 2 to IEC 947-4-1
 - Rated Impulse Withstand Voltage (U<sub>imp</sub>): 8 kV
 - Rated Insulation Voltage (U<sub>i</sub>): acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V acc. to UL/CSA 600 V
 - Terminal Type: Screw Terminals
 - Number of Auxiliary Contacts NO: 0
 - Number of Auxiliary Contacts NC: 0
 - Mechanical Durability: 10 million
 - Connecting Capacity Main Circuit: Flexible with Cable End 0.75 ... 2.5 mm² Rigid Cable 1 ... 4 mm²
 - GOST Certificate: GOST_POCCFRME77B07175
 - Maximum Operating Altitude Permissible: 3000 m
 - Rated Control Circuit Voltage (U<sub>c</sub>): 50 Hz 220 … 230 V 60 Hz 230 … 240 V
 - Climatic Withstand: acc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II
 - Maximum Mechanical Switching Frequency: 3600 cycles per hour
 - Connecting Capacity Auxiliary Circuit: Flexible with Cable End 0.75 ... 2.5 mm² Rigid Cable 1 ... 4 mm²
 - Operate Time: Between Coil Energization and NO Contact Closing 10 ... 26 ms Between Coil De-energization and NO Contact Opening 4 ... 11 ms
 - Number of Main Contacts NO: 4
 - GL Certificate: DNV-GL_TAE00000TX
 - Number of Main Contacts NC: 0
 - Short-Circuit Protective Devices: gG Type Fuses 32 A
 - Maximum Breaking Capacity: cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 250 A cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 90 A
 - Coil Consumption: Pull-in at Max. Rated Control Circuit Voltage 50 Hz 70 V·A Pull-in at Max. Rated Control Circuit Voltage 60 Hz 80 V·A Holding at Max. Rated Control Circuit Voltage 60 Hz 8 V·A Holding at Max. Rated Control Circuit Voltage 60 Hz 2 W Holding at Max. Rated Control Circuit Voltage 50 Hz 8 V·A Holding at Max. Rated Control Circuit Voltage 50 Hz 2 W Average Holding Value 50 / 60 Hz 8 V·A Average Holding Value 50 / 60 Hz 2 W Average Pull-in Value 50 Hz 74 V·A Average Pull-in Value 60 Hz 70 V·A
 - Coil Operating Limits: (acc. to IEC 60947-4-1) 0.85 ... 1.1 x Uc (at θ ≤ 55 °C) °C
 - Connecting terminals (delivered in open position) Main poles: M 3.5 (+,-) pozidriv 2 screws with cable clamp
 - EAN: 3471522051806
 - Minimum Order Quantity: 1 piece
 - Customs Tariff Number: 85369085
 - Package Level 1 Width: 78 mm
 - Package Level 1 Length: 76 mm
 
- Package Level 1 Height: 47 mm
 - Package Level 1 Gross Weight: 0.34 kg
 - Package Level 1 EAN: 3471522051806
 - Package Level 2 Units: 63 piece
 - Package Level 3 Units: 1220 piece
 - Package Level 1 Units: 1 piece
 - Rated Operational Voltage: Main Circuit 690 V
 - Conventional Free-air Thermal Current (I<sub>th</sub>): acc. to IEC 60947-4-1, Open Contactors q = 40 °C 30 A
 - Rated Operational Current AC-1 (I<sub>e</sub>): (690 V) 40 °C 30 A (690 V) 55 °C 27 A (690 V) 70 °C 23 A
 - Rated Operational Current AC-3 (I<sub>e</sub>): (220 / 230 / 240 V) 55 °C 17 A (380 / 400 V) 55 °C 17 A (415 V) 55 °C 17 A (440 V) 55 °C 16 A (500 V) 55 °C 14 A (690 V) 55 °C 10 A
 - Rated Breaking Capacity AC-3 acc. to IEC 60947-4-1: 8 x Ie AC-3
 - Rated Making Capacity AC-3 acc. to IEC 60947-4-1: 10 x Ie AC-3
 - Maximum Electrical Switching Frequency: AC-1 600 cycles per hour AC-2 / AC-4 300 cycles per hour AC-3 1200 cycles per hour
 - Resistance to Shock acc. to IEC 60068-2-27: Shock Direction: A 20 g Closed, Shock Direction: B1 10 g Open, Shock Direction: B1 5 g Shock Direction: B2 15 g Shock Direction: C1 20 g Shock Direction: C2 20 g
 - RoHS Status: Following EU Directive 2002/95/EC August 18, 2005 and amendment
 - Instructions and Manuals: FPTC407721P0001
 - BV Certificate: BV_2634H07559D0
 - CCC Certificate: CCC_2013010304615753 CCC_2004010309130463
 - CSA Certificate: CSA_1041746
 - cUL Certificate: UL_20160205-E312527-10-2
 - Data Sheet, Technical Information: 1SBC100122C0202_Ch02
 - Declaration of Conformity - CE: 1SBD250802U1000
 - DNV Certificate: DNV-GL_TAE00000TX
 - EAC Certificate: EAC_RU C-FR ME77 B01010
 - LOVAG Certificate: LOVAG_FR97081
 - LR Certificate: LRS_9830011E4
 - RINA Certificate: RINA_ELE400503CS1
 - RMRS Certificate: RMRS_0507015250
 - RoHS Information: 1SBD350050R1000
 - UL Certificate: UL_071301E39231
 - UL Listing Card: UL_E312527
 - E-nummer: 3228024
 - ETIM 4: EC000066 - Magnet contactor, AC-switching
 - ETIM 5: EC000066 - Magnet contactor, AC-switching
 - ETIM 6: EC000066 - Power contactor, AC switching
 - UNSPSC: 39121529
 - Object Classification Code: Q
 
                    Santa Clara Systems specializes in hard-to-find parts. Choose from our overstock inventory and save on  A16-40-00-80 . Santa Clara Systems carries 37,095  items from ABB.
                  
                - A16 4-Pole Contactors Are Mainly Used For Controlling Non-Inductive Or Slightly Inductive Loads (I.e. Resistance Furnaces...) And Generally For Controlling Power Circuits Up To 690 V Ac And 440 V Dc. The Contactors Can Also Be Used For Many Other Applications Such Lighting... The A... Series 4-Pole Contactors Are Of The Block Type Design. - Main Poles And Auxiliary Contact Blocks: 4 N.o. Main Poles
 
- A16 4-Pole Contactors Are Mainly Used For Controlling Non-Inductive Or Slightly Inductive Loads (I.e. Resistance Furnaces...) And Generally For Controlling Power Circuits Up To 690 V Ac And 440 V Dc. The Contactors Can Also Be Used For Many Other Applications Such Lighting... The A... Series 4-Pole Contactors Are Of The Block Type Design. - Main Poles And Auxiliary Contact Blocks: 4 N.o. Main Poles
 - Front And Side-Mounted Add-On Auxiliary Contact Blocks - Control Circuit: Ac Operated With Laminated Magnet Circuit - Accessories: A Wide Range Of Accessories Is Available.
 
Alternates
- 1SBL181201R8000
 - A16400080
 
Common Typos
- A16-40-00-8O
 - A16-40-00-B0
 - A16-40-00-BO
 - A16-40-0O-80
 - A16-40-0O-8O
 - A16-40-0O-B0
 - A16-40-0O-BO
 - A16-40-O0-80
 - A16-40-O0-8O
 - A16-40-O0-B0
 - A16-40-O0-BO
 - A16-40-OO-80
 - A16-40-OO-8O
 - A16-40-OO-B0
 - A16-40-OO-BO
 - A16-4O-00-80
 - A16-4O-00-8O
 - A16-4O-00-B0
 - A16-4O-00-BO
 - A16-4O-0O-80
 - A16-4O-0O-8O
 - A16-4O-0O-B0
 - A16-4O-0O-BO
 - A16-4O-O0-80
 - A16-4O-O0-8O
 - A16-4O-O0-B0
 
Appended Numbers
- A16-40-00-80-A
 - A16-40-00-80-B
 - A16-40-00-80-C
 - A16-40-00-80-D
 - A16-40-00-80-E
 - A16-40-00-80-F
 - A16-40-00-80-G
 - A16-40-00-80-H
 - A16-40-00-80-I
 - A16-40-00-80-J
 - A16-40-00-80-K
 - A16-40-00-80-L
 - A16-40-00-80-M
 - A16-40-00-80-N
 - A16-40-00-80-O
 - A16-40-00-80-P
 - A16-40-00-80-Q
 - A16-40-00-80-R
 - A16-40-00-80-S
 - A16-40-00-80-T
 - A16-40-00-80-U
 - A16-40-00-80-V
 - A16-40-00-80-W
 - A16-40-00-80-X
 - A16-40-00-80-Y
 - A16-40-00-80-Z
 
Customers Are Also Buying
- 
                
                855T-B24GL4
Allen Bradley
 - 
                
                440K-C21061
Allen Bradley
 - 
                
                1756-L83E
Allen Bradley
 
We Deliver!
- ✓ Late West Coast Shipping (5PM PST)
 - ✓ Drop-Ship and Blind-Ship Specialists
 - ✓ Expertly Packed Static-Limited
 - ✓ Same-Day Service
 - ✓ In-House Courier
 
    
                  
                  
                  
                  
                  
                  