- Description: Contactor | 1SFL457063R7211
- Product ID: 1SFL457063R7211
- Extended Product Type: 1SFL457063R7211
- Product Net Weight: 2.100 kg
- Product Net Width: 102.0 mm
- Product Net Height: 148.0 mm
- Product Net Depth: 123.5 mm
- Degree of Protection: acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
- Ambient Air Temperature: Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25+50 C Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40+70 C Close to Contactor for Storage -60+80 C
- Rated Impulse Withstand Voltage (U<sub>imp</sub>): Main Circuit 8 kV
- Rated Insulation Voltage (U<sub>i</sub>): acc. to UL/CSA 600 V acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V
- Terminal Type: Cable Clamp
- Number of Auxiliary Contacts NO: 1
- Number of Auxiliary Contacts NC: 1
- Mechanical Durability: 10 million
- Connecting Capacity Main Circuit: Flexible with Cable End 1x1070 mm Bar 30 mm Rigid 2x665 mm
- Maximum Operating Voltage UL/CSA: Main Circuit 600 V
- Maximum Operating Altitude Permissible: 3000 m
- Rated Control Circuit Voltage (U<sub>c</sub>): DC Operation 20 60 V
- Maximum Mechanical Switching Frequency: 300 cycles per hour
- Connecting Capacity Auxiliary Circuit: Solid 2x14 mm Flexible with Insulated Ferrule 2x0.752.5 mm Stranded 2x14 mm Flexible 1x0.752.5 mm Flexible with Ferrule 2x0.752.5 mm
- Operate Time: Between Coil Energization and NO Contact Closing 3080 ms Between Coil De-energization and NO Contact Opening 55125 ms Between Coil De-energization and NC Contact Closing 60130 ms Between Coil Energization and NC Contact Opening 2777 ms
- Number of Main Contacts NO: 3
- GL Certificate: GL_20260-04HH
- Number of Main Contacts NC: 0
- Short-Circuit Protective Devices: gG Type Fuses 160 A
- Maximum Breaking Capacity: cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1160 A cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 800 A
- Coil Consumption: Pull-in at Max. Rated Control Circuit Voltage 60 Hz 350 V·A Holding at Max. Rated Control Circuit Voltage DC 2 W Holding at Max. Rated Control Circuit Voltage 50 Hz 7 V·A Pull-in at Max. Rated Control Circuit Voltage DC 400 W Pull-in at Max. Rated Control Circuit Voltage 50 Hz 350 V·A Holding at Max. Rated Control Circuit Voltage 60 Hz 7 V·A
- Coil Operating Limits: (acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at 70 C) C
- Connecting terminals (delivered in open position) Main poles: M8 hexagon socket screw with single connector
- Horsepower Rating UL/CSA: (208 V AC) Three Phase 30 Hp (440 ... 480 V AC) Three Phase 75 Hp (550 ... 600 V AC) Three Phase 100 Hp (220 ... 240 V AC) Three Phase 40 Hp (200 V AC) Three Phase 30 Hp
- General Use Rating UL/CSA: (600 V AC) 140 A
- EAN: 7320500256480
- Minimum Order Quantity: 1 piece
- Customs Tariff Number: 85364900
- Package Level 1 Width: 140 mm
- Package Level 1 Length: 140 mm
- Package Level 1 Height: 170 mm
- Package Level 1 Gross Weight: 2.1 kg
- Package Level 1 EAN: 7320500256480
- Package Level 1 Units: 1 piece
- Rated Operational Voltage: Main Circuit 1000 V
- Conventional Free-air Thermal Current (I<sub>th</sub>): acc. to IEC 60947-4-1, Open Contactors q = 40 C 160 A
- Rated Operational Current AC-1 (I<sub>e</sub>): (690 V) 55 C 145 A (690 V) 40 C 160 A (690 V) 70 C 130 A
- Rated Operational Current AC-3 (I<sub>e</sub>): (1000 V) 55 C 30 A (220 / 230 / 240 V) 55 C 110 A (690 V) 55 C 82 A (415 V) 55 C 110 A (440 V) 55 C 100 A (380 / 400 V) 55 C 110 A (500 V) 55 C 100 A
- Rated Operational Power AC-3 (P<sub>e</sub>): (500 V) 59 kW (1000 V) 40 kW (220 / 230 / 240 V) 30 kW (690 V) 75 kW (380 / 400 V) 55 kW (440 V) 59 kW (415 V) 59 kW
- Rated Breaking Capacity AC-3 acc. to IEC 60947-4-1: 8 x Ie AC-3
- Rated Making Capacity AC-3 acc. to IEC 60947-4-1: 10 x Ie AC-3
- Maximum Electrical Switching Frequency: AC-3 300 cycles per hour AC-1 300 cycles per hour AC-2 / AC-4 150 cycles per hour
- Rated Operational Current DC-1 (I<sub>e</sub>): (110 V) 2 Poles in Series, 40 C 160 A (220 V) 3 Poles in Series, 40 C 160 A
- Rated Operational Current DC-3 (I<sub>e</sub>): (110 V) 2 Poles in Series, 40 C 160 A (220 V) 3 Poles in Series, 40 C 160 A
- Rated Operational Current DC-5 (I<sub>e</sub>): (110 V) 2 Poles in Series, 40 C 160 A (220 V) 3 Poles in Series, 40 C 160 A
- Resistance to Shock acc. to IEC 60068-2-27: Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: A 20 g Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: C2 20 g Half-sine Pulse for 11 ms, No Change in Contact Position, Closed, Shock Direction: B1 15 g Half-sine Pulse for 11 ms, No Change in Contact Position, Closed, Shock Direction: A 20 g Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: C1 20 g Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: B2 15 g Half-sine Pulse for 11 ms, No Change in Contact Position, Open, Shock Direction: B1 5 g Half-sine Pulse for 11 ms, No Change in Contact Position, Closed, Shock Direction: C2 20 g Half-sine Pulse for 11 ms, No Change in Contact Position, Closed, Shock Direction: C1 20 g
- RoHS Status: Following EU Directive 2002/95/EC August 18, 2005 and amendment
- Instructions and Manuals: 5309660-60
- BV Certificate: 13409/C0 BV
- CB Certificate: SE-73668
- CCC Certificate: CQC_2002010304007860
- Data Sheet, Technical Information: 1SBC100122C0202
- Declaration of Conformity - CE: 1SFA1-66
- LOVAG Certificate: SE9831016
- LR Certificate: LR_04-00015-E1
- RINA Certificate: ELE060313XG/002
- RMRS Certificate: RMRS_12-03683-315
- RoHS Information: 1SFC101055D0202
- ETIM 4: EC000066 - Magnet contactor, AC-switching
- ETIM 5: EC000066 - Magnet contactor, AC-switching
- UNSPSC: 39121529
- Object Classification Code: Q
Santa Clara Systems specializes in hard-to-find parts. Choose from our overstock inventory and save on AF110B-30-11-72 . Santa Clara Systems carries 36,836 items from ABB.
- A 3-Phase Contactor Suitable For Rail Way Applications Application. Operated With A Wide Voltage Control Voltage Range 20-60v
- A 3-Phase Contactor Suitable For Rail Way Applications Application. Operated With A Wide Voltage Control Voltage Range 20-60v
- Dc
Alternates
- 1SFL457063R7211
- AF110B 30 11 72
- AF110B301172
Common Typos
- AF110B-30-11-7Z
- AF110B-30-1I-72
- AF110B-30-1I-7Z
- AF110B-30-1L-72
- AF110B-30-1L-7Z
- AF110B-30-I1-72
- AF110B-30-I1-7Z
- AF110B-30-II-72
- AF110B-30-II-7Z
- AF110B-30-IL-72
- AF110B-30-IL-7Z
- AF110B-30-L1-72
- AF110B-30-L1-7Z
- AF110B-30-LI-72
- AF110B-30-LI-7Z
- AF110B-30-LL-72
- AF110B-30-LL-7Z
- AF110B-3O-11-72
- AF110B-3O-11-7Z
- AF110B-3O-1I-72
- AF110B-3O-1I-7Z
- AF110B-3O-1L-72
- AF110B-3O-1L-7Z
- AF110B-3O-I1-72
- AF110B-3O-I1-7Z
- AF110B-3O-II-72
Appended Numbers
- AF110B-30-11-72-A
- AF110B-30-11-72-B
- AF110B-30-11-72-C
- AF110B-30-11-72-D
- AF110B-30-11-72-E
- AF110B-30-11-72-F
- AF110B-30-11-72-G
- AF110B-30-11-72-H
- AF110B-30-11-72-I
- AF110B-30-11-72-J
- AF110B-30-11-72-K
- AF110B-30-11-72-L
- AF110B-30-11-72-M
- AF110B-30-11-72-N
- AF110B-30-11-72-O
- AF110B-30-11-72-P
- AF110B-30-11-72-Q
- AF110B-30-11-72-R
- AF110B-30-11-72-S
- AF110B-30-11-72-T
- AF110B-30-11-72-U
- AF110B-30-11-72-V
- AF110B-30-11-72-W
- AF110B-30-11-72-X
- AF110B-30-11-72-Y
- AF110B-30-11-72-Z
We Deliver!
- ✓ Late West Coast Shipping (5PM PST)
- ✓ Drop-Ship and Blind-Ship Specialists
- ✓ Expertly Packed Static-Limited
- ✓ Same-Day Service
- ✓ In-House Courier