- Description: AL26-30-10 110V DC Contactor
- Product ID: 1SBL243001R8610
- Extended Product Type: 1SBL243001R8610
- Product Net Weight: 0.750 kg
- Product Net Width: 54 mm
- Product Net Height: 90 mm
- Product Net Depth: 110.6 mm
- Degree of Protection: acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
- Ambient Air Temperature: Close to Contactor Fitted with Thermal O/L Relay -25 ... +55 °C Close to Contactor for Storage -60 ... +80 °C Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... +55 °C Close to Contactor without Thermal O/L Relay (Uc) -40 ... +70 °C
- Rated Impulse Withstand Voltage (U<sub>imp</sub>): 8 kV
- Rated Insulation Voltage (U<sub>i</sub>): acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V acc. to UL/CSA 600 V
- Terminal Type: Screw Terminals
- Rated Frequency (f): Supply Circuit 50 Hz Supply Circuit 60 Hz
- Number of Auxiliary Contacts NO: 1
- Number of Auxiliary Contacts NC: 0
- Connecting Capacity Main Circuit: Rigid Cable 1.5 ... 6 mm² Flexible with Cable End 0.75 ... 4 mm²
- GOST Certificate: GOST_POCCFRME77B07175
- Maximum Operating Altitude Permissible: 3000 m
- Rated Control Circuit Voltage (U<sub>c</sub>): DC Operation 110 V
- Climatic Withstand: acc. to IEC 60068-2-30 and 60068-2-11 - UTE C 63-100 specification II
- Maximum Mechanical Switching Frequency: 3600 cycles per hour
- Connecting Capacity Auxiliary Circuit: Rigid Cable 1 ... 4 mm² Flexible with Cable End 0.75 ... 2.5 mm²
- Operate Time: Between Coil Energization and NO Contact Closing 55 ... 110 ms Between Coil De-energization and NO Contact Opening 12 ... 18 ms
- Number of Main Contacts NO: 3
- GL Certificate: GL_26144_05HH
- Number of Main Contacts NC: 0
- Short-Circuit Protective Devices: Auxiliary Circuit - gG Type Fuses 10 A gG Type Fuses 50 A
- Maximum Breaking Capacity: cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 420 A cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 106 A
- Coil Consumption: Average Holding Value, from Warm State 3.5 W Average Pull-in Value, from Cold State 3.5 W
- Coil Operating Limits: (acc. to IEC 60947-4-1) 0.85 ... 1.1 x Uc (at θ ≤ 55 °C) °C
- Connecting terminals (delivered in open position) Main poles: M 4 (+,-) pozidriv 2 screw with cable clamp
- EAN: 3471522281869
- Minimum Order Quantity: 1 piece
- Customs Tariff Number: 85369085
- Package Level 1 Width: 100 mm
- Package Level 1 Length: 134 mm
- Package Level 1 Height: 62 mm
- Package Level 1 Gross Weight: 0.75 kg
- Package Level 1 EAN: 3471522281869
- Package Level 2 Units: 20 piece
- Package Level 3 Units: 384 piece
- Package Level 1 Units: 1 piece
- Rated Operational Voltage: Main Circuit 690 V Auxiliary Circuit 690 V
- Conventional Free-air Thermal Current (I<sub>th</sub>): acc. to IEC 60947-4-1, Open Contactors q = 40 °C 45 A acc. to IEC 60947-5-1, q = 40 °C 16 A
- Rated Operational Current AC-1 (I<sub>e</sub>): (690 V) 40 °C 45 A (690 V) 55 °C 40 A (690 V) 70 °C 32 A
- Rated Operational Current AC-3 (I<sub>e</sub>): (220 / 230 / 240 V) 55 °C 26 A (380 / 400 V) 55 °C 26 A (415 V) 55 °C 26 A (440 V) 55 °C 26 A (500 V) 55 °C 22 A (690 V) 55 °C 13 A
- Rated Operational Power AC-3 (P<sub>e</sub>): (220 / 230 / 240 V) 6.5 kW (380 / 400 V) 11 kW (415 V) 11 kW (440 V) 15 kW (500 V) 15 kW (690 V) 11 kW
- Rated Breaking Capacity AC-3 acc. to IEC 60947-4-1: 8 x Ie AC-3
- Rated Making Capacity AC-3 acc. to IEC 60947-4-1: 10 x Ie AC-3
- Rated Operational Current AC-15 (I<sub>e</sub>): (220 / 240 V) 4 A (24 / 127 V) 6 A (380 / 440 V) 3 A (500 V) 2 A (690 V) 2 A
- Rated Short-time Withstand Current (I<sub>cw</sub>): at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 210 A at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 45 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 90 A at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 400 A at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 110 A for 0.1 s 140 A for 1 s 100 A
- Maximum Electrical Switching Frequency: AC-1 600 cycles per hour AC-2 / AC-4 300 cycles per hour AC-3 1200 cycles per hour
- Rated Operational Current DC-13 (I<sub>e</sub>): (125 V) 1.1 / 138 A (24 V) 6 / 144 A (250 V) 0.55 / 138 A (48 V) 2.8 / 134 A (72 V) 2 / 144 A
- Resistance to Shock acc. to IEC 60068-2-27: Closed, Shock Direction: A 20 g Open, Shock Direction: A 10 g Closed, Shock Direction: B1 15 g Open, Shock Direction: B1 5 g Shock Direction: B2 10 g Closed, Shock Direction: C1 20 g Open, Shock Direction: C1 8 g Closed, Shock Direction: C2 14 g Open, Shock Direction: C2 8 g
- RoHS Status: Following EU Directive 2002/95/EC August 18, 2005 and amendment
- Instructions and Manuals: 1SBC101007M5501
- CCC Certificate: CCC_2004010304112231
- CSA Certificate: CSA_1033838_LR056745
- Data Sheet, Technical Information: 1SBC100122C0202_Ch02
- Declaration of Conformity - CE: 1SBD250804U1000
- RoHS Information: 1SBD350055R1000
- E-nummer: 3228443
- ETIM 4: EC000066 - Magnet contactor, AC-switching
- ETIM 5: EC000066 - Magnet contactor, AC-switching
- ETIM 6: EC000066 - Power contactor, AC switching
- UNSPSC: 39121529
- Object Classification Code: Q
Santa Clara Systems specializes in hard-to-find parts. Choose from our overstock inventory and save on AL26-30-10-86 . Santa Clara Systems carries 36,972 items from ABB.
- 1 Built-In Auxiliary Contact
- Front And Side-Mounted Add-On Auxiliary Contact Blocks - Control Circuit: Dc Operated With Solid Core Magnet Circuit. The Polarity On The Coil Terminals (A1+ And A2-) Must Be Respected - Accessories: A Wide Range Of Accessories Is Available. Al... Contactors Are Fitted With Low Consumption Dc Coils And Are Suitable For A Direct Control By Plc Outputs.
- Al26 Contactors Are Mainly Used For Controlling 3-Phase Motors And Generally For Controlling Power Circuits Up To 690 V Ac Or 220 V Dc. The Contactors Can Also Be Used For Many Other Applications Such As Isolation
- Capacitor Switching
- Lighting. The Al... Series 1-Stack 3-Pole Contactors Are Of The Block Type Design. - Main Poles And Auxiliary Contact Blocks: 3 Main Poles
Alternates
- 1SBL243001R8610
- AL26 30 10 86
- AL26301086
Common Typos
- AL26-30-10-8G
- AL26-30-10-B6
- AL26-30-10-BG
- AL26-30-1O-86
- AL26-30-1O-8G
- AL26-30-1O-B6
- AL26-30-1O-BG
- AL26-30-I0-86
- AL26-30-I0-8G
- AL26-30-I0-B6
- AL26-30-I0-BG
- AL26-30-IO-86
- AL26-30-IO-8G
- AL26-30-IO-B6
- AL26-30-IO-BG
- AL26-30-L0-86
- AL26-30-L0-8G
- AL26-30-L0-B6
- AL26-30-L0-BG
- AL26-30-LO-86
- AL26-30-LO-8G
- AL26-30-LO-B6
- AL26-30-LO-BG
- AL26-3O-10-86
- AL26-3O-10-8G
- AL26-3O-10-B6
Appended Numbers
- AL26-30-10-86-A
- AL26-30-10-86-B
- AL26-30-10-86-C
- AL26-30-10-86-D
- AL26-30-10-86-E
- AL26-30-10-86-F
- AL26-30-10-86-G
- AL26-30-10-86-H
- AL26-30-10-86-I
- AL26-30-10-86-J
- AL26-30-10-86-K
- AL26-30-10-86-L
- AL26-30-10-86-M
- AL26-30-10-86-N
- AL26-30-10-86-O
- AL26-30-10-86-P
- AL26-30-10-86-Q
- AL26-30-10-86-R
- AL26-30-10-86-S
- AL26-30-10-86-T
- AL26-30-10-86-U
- AL26-30-10-86-V
- AL26-30-10-86-W
- AL26-30-10-86-X
- AL26-30-10-86-Y
- AL26-30-10-86-Z
We Deliver!
- ✓ Late West Coast Shipping (5PM PST)
- ✓ Drop-Ship and Blind-Ship Specialists
- ✓ Expertly Packed Static-Limited
- ✓ Same-Day Service
- ✓ In-House Courier