- Description: Manual Motor Starter | 1SAM350000R1011
- Product ID: 1SAM350000R1011
- Extended Product Type: 1SAM350000R1011
- Product Net Weight: 0.31 kg
- Product Net Width: 45 mm
- Product Net Height: 97.8 mm
- Product Net Depth: 86.55 mm
- Degree of Protection: Housing IP20 Main Circuit Terminals IP10
- Ambient Air Temperature: Around the Enclosure 0 ... +40 C Operation -25 ... +70 C Operation Compensated -25 ... +60 C Storage -50 ... +80 C
- Standards: IEC/EN 60947-1 IEC/EN 60947-2 IEC/EN 60947-4-1 UL 60947-1 UL 60947-4-1
- Rated Impulse Withstand Voltage (U<sub>imp</sub>): Main Circuit 6 kV
- Rated Insulation Voltage (U<sub>i</sub>): 690 V
- Number of Poles: 3
- Rated Frequency (f): Main Circuit 50 Hz Main Circuit 60 Hz
- Power Loss: at Rated Operating Conditions per Pole 1.1 ... 2.8 W
- Mounting on DIN Rail: TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
- eClass: 7.0 27370401
- Tightening Torque: Main Circuit 2 N·m
- Actuator Type: Rotary Handle
- Mounting Position: Position 1 to 6
- Mechanical Durability: 100000 cycle
- Connecting Capacity Main Circuit: Flexible with Ferrule 1/2x 0.75 ... 6 mm Flexible with Insulated Ferrule 1/2x 0.75 ... 6 mm Flexible 1/2x 1 ... 2.5 mm Flexible 1/2x 2.5 ... 6 mm Rigid 1/2x 1 ... 2.5 mm Rigid 1/2x 2.5 ... 6 mm
- GOST Certificate: 1SAA963001-2702
- Maximum Operating Voltage UL/CSA: Main Circuit 600 V AC
- Contact Position Indication: ON / OFF / TRIP
- Maximum Operating Altitude Permissible: 2000 m
- Tightening Torque UL/CSA: Main Circuit 18 in·lb
- Country of Origin: Germany (DE)
- Wire Stripping Length: Main Circuit 10 mm
- GL Certificate: 1SAA963001-0401
- Connecting Capacity Main Circuit UL/CSA: Flexible 1/2x 16-8 AWG Stranded 1/2x 16-8 AWG
- Ampere Rating UL/CSA: 16 A
- Horsepower Rating UL/CSA: (220 ... 240 V AC) Three Phase 5 Hp (440 ... 480 V AC) Three Phase 10 Hp (550 ... 600 V AC) Three Phase 10 Hp
- General Use Rating UL/CSA: (600 V AC) 16 A
- Lead Time: 26 day(s)
- Electrical Durability: 50000 cycle
- EAN: 4013614400117
- Criticality: No
- Made To Order: No
- Product Sales Status: Active
- Quote Only: No
- Storage Location: 4001
- Minimum Order Quantity: 1 piece
- Customs Tariff Number: 85362010
- Package Level 1 Width: 92 mm
- Package Level 1 Length: 102 mm
- Package Level 1 Height: 50 mm
- Package Level 1 Gross Weight: 0.325 kg
- Package Level 2 Units: 40 piece
- Package Level 2 Width: 280 mm
- Package Level 2 Length: 395 mm
- Package Level 2 Height: 210 mm
- Package Level 2 Gross Weight: 13.386 kg
- Package Level 2 EAN: 4013614409011
- Package Level 1 Units: 1 piece
- Rated Ultimate Short-Circuit Breaking Capacity (I<sub>cu</sub>): (230 V AC) 100 kA (400 V AC) 100 kA (440 V AC) 20 kA (500 V AC) 20 kA (690 V AC) 3 kA
- Rated Instantaneous Short-Circuit Current Setting (I<sub>i</sub>): 240 A
- Setting Range: 10 ... 16 A
- Rated Operational Power AC-3 (P<sub>e</sub>): (400 V) Three Phase 7.5 kW
- Rated Operational Voltage: Main Circuit 690 V AC Main Circuit 250 V DC
- Rated Operational Current (I<sub>e</sub>): 16 A
- Rated Operational Current AC-3 (I<sub>e</sub>): 16 A
- Rated Operational Current DC-5 (I<sub>e</sub>): 16 A
- Conventional Free-air Thermal Current (I<sub>th</sub>): Main Circuit 16 A
- Pollution Degree: 3
- Recommended Screw Driver: Pozidriv 2
- Rated Service Short-Circuit Breaking Capacity (I<sub>cs</sub>): (230 V AC) 100 kA (250 V DC) 3 Poles in Series 10 kA (400 V AC) 100 kA (440 V AC) 20 kA (500 V AC) 20 kA (690 V AC) 3 kA
- Ambient Air Temperature Compensation: Yes
- Resistance to Shock acc. to IEC 60068-2-27: 11 ms Pulse 25g
- Resistance to Vibrations acc. to IEC 60068-2-6: 5g / 3 ... 150 Hz
- RoHS Status: Following EU Directive 2002/95/EC August 18, 2005 and amendment
- Data Sheet, Technical Information (Part 2): 1SAM300505F0011
- Data Sheet, Technical Information (Part 3): 1SAM300507F0001 1SAM300507F0003 1SAM300508F0001 1SAM300508F0003
- Instructions and Manuals: 2CDC131022M6802
- ABS Certificate: 1SAA963001-0101
- ATEX Certificate: 1SAA963000-3901
- BV Certificate: 1SAA963001-0201
- CB Certificate: 1SAA963002-2001
- CCC Certificate: 1SAA963001-3804
- cUL Certificate: cUL_E137861 cUL_E345003
- cULus Certificate: cUL_E137861
- Data Sheet, Technical Information: 2CDC131021D0201
- Declaration of Conformity - CE: 1SAD938510-0125
- DNV Certificate: 1SAA963001-0303
- EAC Certificate: 1SAA963000-2701
- LR Certificate: 1SAA963001-0502
- RINA Certificate: 1SAA963000-0802
- RMRS Certificate: 1SAA918000-0703
- RoHS Information: 1SAA963002-4405
- UL Certificate: UL_E137861 UL_E345003
- E-nummer: 3112127
- ETIM 4: EC000074 - Motor protective circuit-breaker
- ETIM 5: EC000074 - Motor protective circuit-breaker
- ETIM 6: EC000074 - Motor protection circuit-breaker
- UNSPSC: 39121521
- Object Classification Code: F
Santa Clara Systems specializes in hard-to-find parts. Choose from our overstock inventory and save on MS132-16 . Santa Clara Systems carries 36,687 items from ABB.
- Undervoltage Releases
- Shunt Trips
- 3-Phase Bus Bars
- Power In-Feed Blocks Are Available As Accessory.
- The Ms132-16 Manual Motor Starter Is A Compact 45 Mm Width Devices With A Rated Operational Current Of Ie = 16.0 A. This Device Is Used To Manually Switch On And Off Motors And To Protect Them Reliably And Without The Need For A Fuse From Short-Circuits
- Overload And Phase Failures. The Manual Motor Starter Offers A Rated Service Short-Circuit Breaking Capacity Ics = 100 Ka At 400 Vac And The Trip Class 10. Further Features Are The Build-In Disconnect Function
- Temperature Compensation
- Trip-Free Mechanism And A Rotary Handle With A Clear Switch Position Indication. The Manual Motor Starter Is Suitable For Three- And Single-Phase Applications. The Handle Is Lockable To Protect Against Unauthorized Changes. Auxiliary Contacts
- Signalling Contacts
Alternates
- 1SAM350000R1011
- MS132 16
- MS13216
Common Typos
- MS132-1G
- MS132-I6
- MS132-IG
- MS132-L6
- MS132-LG
- MS13Z-16
- MS13Z-1G
- MS13Z-I6
- MS13Z-IG
- MS13Z-L6
- MS13Z-LG
- MSI32-16
- MSI32-1G
- MSI32-I6
- MSI32-IG
- MSI32-L6
- MSI32-LG
- MSI3Z-16
- MSI3Z-1G
- MSI3Z-I6
- MSI3Z-IG
- MSI3Z-L6
- MSI3Z-LG
- MSL32-16
- MSL32-1G
- MSL32-I6
Appended Numbers
- MS132-16-A
- MS132-16-B
- MS132-16-C
- MS132-16-D
- MS132-16-E
- MS132-16-F
- MS132-16-G
- MS132-16-H
- MS132-16-I
- MS132-16-J
- MS132-16-K
- MS132-16-L
- MS132-16-M
- MS132-16-N
- MS132-16-O
- MS132-16-P
- MS132-16-Q
- MS132-16-R
- MS132-16-S
- MS132-16-T
- MS132-16-U
- MS132-16-V
- MS132-16-W
- MS132-16-X
- MS132-16-Y
- MS132-16-Z
Customers Are Also Buying
-
G2R-2-SND-DC24(S)
Omron
-
872C-A5N18-A2
Allen Bradley
-
872C-D10NP30-D4
Allen Bradley
We Deliver!
- ✓ Late West Coast Shipping (5PM PST)
- ✓ Drop-Ship and Blind-Ship Specialists
- ✓ Expertly Packed Static-Limited
- ✓ Same-Day Service