- Description: Control Relay
- Product weight: 1.28 lb(US) (0.58 kg)
- IP degree of protection: IP2x front face conforming to VDE 0106
- Standards: VDE 0660IEC 60947-5-1NF C 63-140BS 4794EN 60947-5
- Device short name: CAD
- Width: 1.77 in (45 mm)
- Height: 3.03 in (77 mm)
- Depth: 3.31 in (84 mm)
- Protective treatment: TH conforming to IEC 60068
- [Ui] rated insulation voltage: 690 V conforming to IEC 60947-5-1600 V certifications UL600 V certifications CSA
- [Uimp] rated impulse withstand voltage: 6 kV conforming to IEC 60947
- Operating altitude: 9842.52 ft. (3000 m) without derating in temperature
- Mechanical durability: 30 Mcycles
- Tightening torque: 10.62 lbf.in (1.2 N.m) - on screw clamp terminals - with screwdriver Philips No 210.62 lbf.in (1.2 N.m) - on screw clamp terminals - with screwdriver flat Ø 6 mm
- Connections - terminals: Screw clamp terminals 1 cable(s) 0...0.01 in² (1...4 mm²) - cable stiffness: flexible - without cable endScrew clamp terminals 2 cable(s) 0...0.01 in² (1...4 mm²) - cable stiffness: flexible - without cable endScrew clamp terminals 1 cable(s) 0...0.01 in² (1...4 mm²) - cable stiffness: flexible - with cable endScrew clamp terminals 2 cable(s) 0...0 in² (1...2.5 mm²) - cable stiffness: flexible - with cable endScrew clamp terminals 1 cable(s) 0...0.01 in² (1...4 mm²) - cable stiffness: solid - without cable endScrew clamp terminals 2 cable(s) 0...0.01 in² (1...4 mm²) - cable stiffness: solid - without cable end
- Range: TeSys
- Mounting support: PlateRail
- [Ith] conventional free air thermal current: 10 A at <= 140 °F (60 °C)
- System Voltage: <= 690 V AC 25...400 Hz
- Operating rate: 180 cyc/mn
- Product name: TeSys CAD
- [Uc] control circuit voltage: 480 V AC 50/60 Hz
- Insulation resistance: > 10 MOhm
- Utilization category: AC-15DC-13AC-14
- Control circuit voltage limits: 0.3...0.6 Uc drop-out0.8...1.1 Uc operational 50 Hz0.85...1.1 Uc operational 60 Hz
- Operating time: 12...22 ms coil energisation and NO closing4...12 ms coil de-energisation and NO opening
- Associated fuse rating: 10 A gG conforming to IEC 60947-5-1
- Control circuit type: AC 50/60 Hz
- Pole contact composition: 5 NO
- Product certifications: ULCSA
- Product or component type: Control relay
- Contactor application: Control circuit
- Ambient air temperature for operation: -40...158 °F (-40...70 °C)
- Ambient air temperature for storage: -76...176 °F (-60...80 °C)
- Irms rated making capacity: 140 A AC conforming to IEC 60947-5-1250 A DC conforming to IEC 60947-5-1
- [Icw] rated short-time withstand current: 100 A 1 s120 A 500 ms140 A 100 ms
- inrush power in VA: 70 VAat 68 °F (20 °C) 50 Hz
- hold-in power consumption in VA: 8 VA at 68 °F (20 °C) 50 Hz
- Minimum switching voltage: 17 V
- Minimum switching current: 5 mA
- Non-overlap time: 1.5 ms on de-energisation (between NC and NO contact)1.5 ms on energisation (between NC and NO contact)
- Mechanical robustness: Shocks control relay open 10 Gn for 11 ms IEC 60068-2-27Shocks control relay closed 15 Gn for 11 ms IEC 60068-2-27Vibrations control relay open 2 Gn, 5...300 Hz IEC 60068-2-6Vibrations control relay closed 4 Gn, 5...300 Hz IEC 60068-2-6
Santa Clara Systems specializes in hard-to-find parts. Choose from our overstock inventory and save on CAD50T7 . Santa Clara Systems carries 10,625 items from Telemecanique.
- Tesys D Control Relay - 5 No - <= 690 V - 480 V Ac Standard Coil
Alternates
Common Typos
- CAD5OT7
- CADS0T7
- CADSOT7
Appended Numbers
- CAD50T7-A
- CAD50T7-B
- CAD50T7-C
- CAD50T7-D
- CAD50T7-E
- CAD50T7-F
- CAD50T7-G
- CAD50T7-H
- CAD50T7-I
- CAD50T7-J
- CAD50T7-K
- CAD50T7-L
- CAD50T7-M
- CAD50T7-N
- CAD50T7-O
- CAD50T7-P
- CAD50T7-Q
- CAD50T7-R
- CAD50T7-S
- CAD50T7-T
- CAD50T7-U
- CAD50T7-V
- CAD50T7-W
- CAD50T7-X
- CAD50T7-Y
- CAD50T7-Z
We Deliver!
- ✓ Late West Coast Shipping (5PM PST)
- ✓ Drop-Ship and Blind-Ship Specialists
- ✓ Expertly Packed Static-Limited
- ✓ Same-Day Service
- ✓ In-House Courier