Current response time:

5 Minutes 44 Seconds
  • Description: standard control unit LUCA - class 10 - 4.5...18 A - 110...220 V DC/AC
  • Product weight: 0.3 lb(US) (0.135 kg)
  • IP degree of protection: IP20 front panel and wired terminals conforming to IEC 60947-1, IP20 other faces conforming to IEC 60947-1, IP40 front panel outside connection zone conforming to IEC 60947-1
  • Standards: CSA C22.2 No 14 type E, EN 60947-6-2, IEC 60947-6-2, UL 508 type E with phase barrier
  • Device short name: LUCA
  • Protective treatment: TH conforming to IEC 60068
  • [Ui] rated insulation voltage: 600 V conforming to CSA C22.2 No 14, 600 V conforming to UL 508, 690 V conforming to IEC 60947-1
  • [Uimp] rated impulse withstand voltage: 6 kV conforming to IEC 60947-6-2
  • Operating altitude: 6561.68 ft. (2000 m)
  • Range: TeSys
  • Product name: TeSys U
  • [Uc] control circuit voltage: 110...220 V DC, 110...240 V AC
  • Shock resistance: 10 gn power poles open conforming to IEC 60068-2-27, 15 gn power poles closed conforming to IEC 60068-2-27
  • Vibration resistance: 2 gn 5...300 Hz power poles open conforming to IEC 60068-2-6, 4 gn 5...300 Hz power poles closed conforming to IEC 60068-2-6
  • motor power kW: 15 kW at 690 V AC 50/60 Hz, 9 kW at 500 V AC 50/60 Hz, 7.5 kW at 400...440 V AC 50/60 Hz
  • Utilization category: AC-44, AC-43, AC-41
  • Control circuit voltage limits: 88...242 V DC circuit 110...220 V in operation, 88...264 V AC circuit 110...240 V in operation
  • Operating time: 35 ms opening with LUB12 control circuit, 35 ms opening with LUB32 control circuit, 50 ms closing with LUB12 control circuit, 50 ms closing with LUB32 control circuit
  • Function available: Protection against overload and short-circuit, Protection against phase failure and phase imbalance, Earth fault protection, Manual reset
  • Heat dissipation: 3 W control circuit with LUB32
  • Mounting mode: Plug-in
  • Immunity to micro breaks: 3 ms
  • Mounting location: Front side
  • Immunity to voltage dips: 70 % 500 ms conforming to IEC 61000-4-11
  • Product or component type: Standard control unit
  • Product specific application: Basic protection requirements for motor starters: overload and short-circuit
  • Typical current consumption: 25 mA at 110...240 V AC I rms sealed with LUB12, 25 mA at 110...240 V AC I rms sealed with LUB32, 280 mA at 110...220 V DC I maximum while closing with LUB12, 280 mA at 110...220 V DC I maximum while closing with LUB32, 280 mA at 110...240 V AC I maximum while closing with LUB12, 280 mA at 110...240 V AC I maximum while closing with LUB32, 35 mA at 110...220 V DC I rms sealed with LUB12, 35 mA at 110...220 V DC I rms sealed with LUB32
  • Product certifications: ATEX, GOST, ABS, ASEFA, BV, UL, CCC, CSA, DNV, LROS (Lloyds register of shipping), GL
  • Product compatibility: LUFC00, LUFN
  • Load type: 3-phase motor - cooling: self-cooled
  • Tripping threshold: 14.2 x Ir +/- 20 %
  • Ambient air temperature for operation: -13...158 F (-25...70 C)
  • Thermal protection adjustment range: 4.5...18 A
  • Ambient air temperature for storage: -40...185 F (-40...85 C)
  • Thermal overload class: Class 10 - frequency limit: 40...60 Hz - temperature compensation: -13...158 F (-25...70 C) - conforming to IEC 60947-6-2, Class 10 - frequency limit: 40...60 Hz - temperature compensation: -13...158 F (-25...70 C) - conforming to UL 508, Class 20 - frequency limit: 40...60 Hz - temperature compensation: -13...158 F (-25...70 C) - conforming to IEC 60947-6-2, Class 20 - frequency limit: 40...60 Hz - temperature compensation: -13...158 F (-25...70 C) - conforming to UL 508
  • Safe separation of circuit: 400 V SELV between the control and auxiliary circuits conforming to IEC 60947-1, 400 V SELV between the control or auxiliary circuit and the main circuit conforming to IEC 60947-1
  • Fire resistance: 1202 F (650 C) conforming to IEC 60695-2-12, 1760 F (960 C) parts supporting live components conforming to IEC 60695-2-12
  • Resistance to electrostatic discharge: 8 kV level 3 in open air conforming to IEC 61000-4-2, 8 kV level 4 on contact conforming to IEC 61000-4-2
  • Non-dissipating shock wave: 1 kV serial mode conforming to IEC 60947-6-2, 2 kV common mode conforming to IEC 60947-6-2
  • Resistance to radiated fields: 9.14 V/yd (10 V/m) 3 conforming to IEC 61000-4-3
  • Resistance to fast transients: 2 kV class 3 serial link conforming to IEC 61000-4-4, 4 kV class 4 all circuits except for serial link conforming to IEC 61000-4-4
  • Immunity to radio electric fields: 10 V conforming to IEC 61000-4-6
Santa Clara Systems specializes in hard-to-find parts. Choose from our overstock inventory and save on LUCA18FU . Santa Clara Systems carries 10,295 items from Telemecanique.
  • Standard Control Unit Luca - Class 10 - 4.5...18 A - 110...220 V Dc/ac

Alternates

    Common Typos

    • 1UCA18FU
    • 1UCA1BFU
    • 1UCAI8FU
    • 1UCAIBFU
    • 1UCAL8FU
    • 1UCALBFU
    • IUCA18FU
    • IUCA1BFU
    • IUCAI8FU
    • IUCAIBFU
    • IUCAL8FU
    • IUCALBFU
    • LUCA1BFU
    • LUCAI8FU
    • LUCAIBFU
    • LUCAL8FU
    • LUCALBFU

    Appended Numbers

    • LUCA18FU-A
    • LUCA18FU-B
    • LUCA18FU-C
    • LUCA18FU-D
    • LUCA18FU-E
    • LUCA18FU-F
    • LUCA18FU-G
    • LUCA18FU-H
    • LUCA18FU-I
    • LUCA18FU-J
    • LUCA18FU-K
    • LUCA18FU-L
    • LUCA18FU-M
    • LUCA18FU-N
    • LUCA18FU-O
    • LUCA18FU-P
    • LUCA18FU-Q
    • LUCA18FU-R
    • LUCA18FU-S
    • LUCA18FU-T
    • LUCA18FU-U
    • LUCA18FU-V
    • LUCA18FU-W
    • LUCA18FU-X
    • LUCA18FU-Y
    • LUCA18FU-Z

    Customers Are Also Buying

    We Deliver!

    Late West Coast Shipping Hours
    Late West Coast Shipping (5PM PST)
    Drop-Ship and Blind-Ship Specialists
    Expertly Packed Static-Limited
    Same-Day Service
    In-House Courier
    visa credit card logo mastercard credit card logo discover credit card logo american express credit card logo

    Customers we work with

    3M logo
    Kaiser Permanente logo
    Safeway Logo
    Georgia-Pacific logo
    Coca Cola logo
    duke energy logo
    BART logo
    Pepsi logo
    LA DWP logo
    US Navy logo
    Dean Foods logo
    ConAgra Brands logo