  • Description: Overload Relay
  • IP degree of protection: IP20 front panel and wired terminals conforming to IEC 60947-1
  • Standards: UL 508 type E, with phase barrier
  • Device short name: LUCD
  • Protective treatment: TH conforming to IEC 60068
  • [Ui] rated insulation voltage: 600 V conforming to UL 508
  • [Uimp] rated impulse withstand voltage: 6 kV IEC 60947-6-2
  • Operating altitude: 2000 m
  • Range: TeSys
  • Product name: TeSys U
  • Shock resistance: 10 gn power poles open conforming to IEC 60068-2-27
  • Vibration resistance: 2 gn, 5…300 Hz, power poles open conforming to IEC 60068-2-6
  • motor power kW: 0.09 kW at 400...440 V AC 50/60 Hz
  • Control circuit voltage limits: 20...27 V for DC circuit 24 V in operation
  • Operating time: 35 ms opening with LUB12 for control circuit
  • Utilisation category: AC-41
  • Thermal protection adjustment range: 0.15…0.6 A
  • Thermal overload class: Class 20 - frequency limit: 40…60 Hz - temperature compensation: -25…70 °C conforming to IEC 60947-6-2
  • Main function available: Protection against phase failure and phase imbalance
  • Mounting mode: Plug-in
  • Mounting location: Front side
  • Typical current consumption: 130 mA at 24 V DC I maximum while closing with LUB12
  • Load type: 3-phase motor - cooling: self-cooled
  • Tripping threshold: 14.2 x Ir +/- 20 %
  • Safe separation of circuit: 400 V SELV between the control and auxiliary circuits conforming to IEC 60947-1
  • Heat dissipation: 2 W for control circuit with LUB12
  • Immunity to microbreaks: 3 ms
  • Immunity to voltage dips: 70 % / 500 ms conforming to IEC 61000-4-11
  • Ambient air temperature for operation: -25…70 °C
  • Fire resistance: 960 °C parts supporting live components conforming to IEC 60695-2-12
  • Resistance to electrostatic discharge: 8 kV level 3 in open air conforming to IEC 61000-4-2
  • Resistance to radiated fields: 10 V/m 3 conforming to IEC 61000-4-3
  • Resistance to fast transients: 2 kV class 3 serial link conforming to IEC 61000-4-4
  • Immunity to radioelectric fields: 10 V conforming to IEC 61000-4-6
Santa Clara Systems specializes in hard-to-find parts. Choose from our overstock inventory and save on LUCDX6BL . Santa Clara Systems carries 10,632 items from Telemecanique.
We are in the process of adding data and downloadable material for this item. Please search similar items for more information related to this product.

Alternates

    Common Typos

    • 1UCDX681
    • 1UCDX68I
    • 1UCDX68L
    • 1UCDX6B1
    • 1UCDX6BI
    • 1UCDX6BL
    • 1UCDXG81
    • 1UCDXG8I
    • 1UCDXG8L
    • 1UCDXGB1
    • 1UCDXGBI
    • 1UCDXGBL
    • IUCDX6B1
    • IUCDX6BI
    • IUCDX6BL
    • LUCDX681
    • LUCDX68I
    • LUCDX68L
    • LUCDX6B1
    • LUCDX6BI
    • LUCDXG81
    • LUCDXG8I
    • LUCDXG8L
    • LUCDXGB1
    • LUCDXGBI
    • LUCDXGBL

    Appended Numbers

    • LUCDX6BL-A
    • LUCDX6BL-B
    • LUCDX6BL-C
    • LUCDX6BL-D
    • LUCDX6BL-E
    • LUCDX6BL-F
    • LUCDX6BL-G
    • LUCDX6BL-H
    • LUCDX6BL-I
    • LUCDX6BL-J
    • LUCDX6BL-K
    • LUCDX6BL-L
    • LUCDX6BL-M
    • LUCDX6BL-N
    • LUCDX6BL-O
    • LUCDX6BL-P
    • LUCDX6BL-Q
    • LUCDX6BL-R
    • LUCDX6BL-S
    • LUCDX6BL-T
    • LUCDX6BL-U
    • LUCDX6BL-V
    • LUCDX6BL-W
    • LUCDX6BL-X
    • LUCDX6BL-Y
    • LUCDX6BL-Z

    Customers Are Also Buying

    We Deliver!

    Late West Coast Shipping Hours
    Late West Coast Shipping (5PM PST)
    Drop-Ship and Blind-Ship Specialists
    Expertly Packed Static-Limited
    Same-Day Service
    In-House Courier
    visa credit card logo mastercard credit card logo discover credit card logo american express credit card logo

    Customers we work with

    3M logo
    Kaiser Permanente logo
    Safeway Logo
    Georgia-Pacific logo
    Coca Cola logo
    duke energy logo
    BART logo
    Pepsi logo
    LA DWP logo
    US Navy logo
    Dean Foods logo
    ConAgra Brands logo