• ABB 1SAM250000R1013 MS116-20 Manual Motor Starter Product Image
  • Abb 1SAM250000R1013 Barcode

1SAM250000R1013

Product Summary:

  • Extended Product Type: MS116-20
  • Product ID: 1SAM250000R1013
  • EAN: 4013614405655
  • Minimum Order Quantity: 1 piece
  • Customs Tariff Number: 85362010
Let Us Find It
           or           
  • Description: MS116-20 Manual Motor Starter
  • Actuator Type: Rotary Handle
  • Contact Position Indication: ON / OFF / TRIP
  • Mounting on DIN Rail: TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
  • Standards: IEC/EN 60947-1 IEC/EN 60947-2 IEC/EN 60947-4-1 UL 60947-1 UL 60947-4-1
  • Rated Service Short-Circuit Breaking Capacity (Ics): (230 V AC) 10 kA (400 V AC) 10 kA (440 V AC) 3 kA (500 V AC) 3 kA (690 V AC) 2 kA
  • Ambient Air Temperature Compensation: Yes
  • Maximum Operating Altitude Permissible: 2000 m
  • Resistance to Shock acc. to IEC 60068-2-27: 11 ms Pulse 25g
  • Resistance to Vibrations acc. to IEC 60068-2-6: 2g / 5 ... 150 Hz
  • RoHS Status: Following EU Directive 2002/95/EC August 18, 2005 and amendment
  • Ambient Air Temperature: Around the Enclosure 0 ... +40 °C Operation -25 ... +75 °C Operation Compensated -25 ... +55 °C Storage -50 ... +85 °C
  • Horsepower Rating UL/CSA: (220 ... 240 V AC) Three Phase 5 Hp (440 ... 480 V AC) Three Phase 10 Hp (550 ... 600 V AC) Three Phase 15 Hp
  • Ampere Rating UL/CSA: 20 A
  • General Use Rating UL/CSA: (600 V AC) 20 A
  • Connecting Capacity Main Circuit UL/CSA: Flexible 1/2x 16-8 AWG Stranded 1/2x 16-8 AWG
  • Connecting Capacity Auxiliary Circuit UL/CSA: Flexible 1/2x 16-14 AWG Stranded 1/2x 16-14 AWG
  • Tightening Torque UL/CSA: Auxiliary Circuit 7 ... 1 in·lb Main Circuit 40 in·lb
  • Contact Rating UL/CSA: B300 R300
  • Maximum Operating Voltage UL/CSA: Main Circuit 600 V AC Auxiliary Circuit 250 V AC/DC
  • Data Sheet, Technical Information (Part 2): 1SAM200505F0013
  • Data Sheet, Technical Information (Part 3): 1SAM200507F0001 1SAM200507F0002 1SAM200507F0003 1SAM200508F0001 1SAM200508F0002 1SAM200508F0003
  • Instructions and Manuals: 2CDC131011M6802
  • ABS Certificate: 1SAA963000-0104
  • CB Certificate: 1SAA963000-2003
  • CCC Certificate: 1SAA963000-3803
  • cUL Certificate: cUL_E137861
  • Data Sheet, Technical Information: 2CDC131025D0201
  • Declaration of Conformity - CE: 1SAD938516-0060
  • DNV Certificate: 1SAA963000-0303
  • EAC Certificate: 1SAA963000-2701
  • GL Certificate: 1SAA963000-0402
  • GOST Certificate: 1SAA963001-2702
  • LR Certificate: 1SAA963000-0505
  • RMRS Certificate: 1SAA918000-0703
  • RoHS Information: 1SAA963001-4407
  • UL Certificate: UL_E137861
  • E-nummer: 3111951
  • ETIM 4: EC000074 - Motor protective circuit-breaker
  • ETIM 5: EC000074 - Motor protective circuit-breaker
  • ETIM 6: EC000074 - Motor protection circuit-breaker
  • eClass: 7.0 27370401
  • UNSPSC: 39121521
  • Object Classification Code: F
  • Extended Product Type: MS116-20
  • Product ID: 1SAM250000R1013
  • EAN: 4013614405655
  • Minimum Order Quantity: 1 piece
  • Customs Tariff Number: 85362010
  • EAN: 4013614405655
  • Package Level 1 Width: 92 mm
  • Package Level 1 Length: 102 mm
  • Package Level 1 Height: 50 mm
  • Package Level 1 Gross Weight: 0.325 kg
  • Package Level 2 Units: 40 piece
  • Package Level 2 Width: 280 mm
  • Package Level 2 Length: 395 mm
  • Package Level 2 Height: 210 mm
  • Package Level 2 Gross Weight: 13.386 kg
  • Package Level 2 EAN: 4013614408731
  • Package Level 1 Units: 1 piece
  • Product Net Height: 97.8 mm
  • Product Net Depth: 86.55 mm
  • Product Net Weight: 0.31 kg
  • Product Net Width: 45 mm
  • Rated Ultimate Short-Circuit Breaking Capacity (Icu): (230 V AC) 15 kA (400 V AC) 15 kA (440 V AC) 6 kA (500 V AC) 4 kA (690 V AC) 2 kA
  • Rated Instantaneous Short-Circuit Current Setting (Ii): 300 A
  • Setting Range: 18 ... 25 A
  • Rated Operational Power AC-3 (Pe): (400 V) Three Phase 7.5 kW
  • Rated Operational Voltage: Main Circuit 690 V AC
  • Rated Operational Current (Ie): 20 A
  • Rated Operational Current AC-3 (Ie): 20 A
  • Rated Frequency (f): Main Circuit 50 Hz Main Circuit 60 Hz
  • Rated Impulse Withstand Voltage (Uimp): Main Circuit 6 kV
  • Rated Insulation Voltage (Ui): 690 V
  • Power Loss: at Rated Operating Conditions per Pole 1.5 ... 2.3 W
  • Number of Poles: 3
  • Mounted Auxiliary Contacts: 1 NO, 1 NC
  • Conventional Free-air Thermal Current (Ith): Main Circuit 20 A
  • Degree of Protection: Housing IP20 Main Circuit Terminals IP10
  • Pollution Degree: 3
  • Electrical Durability: 50000 cycle
  • Mechanical Durability: 100000 cycle
  • Connecting Capacity Main Circuit: Flexible with Ferrule 1/2x 0.75 ... 6 mm² Flexible with Insulated Ferrule 1/2x 0.75 ... 6 mm² Flexible 1/2x 1 ... 2.5 mm² Flexible 1/2x 2.5 ... 6 mm² Rigid 1/2x 1 ... 2.5 mm² Rigid 1/2x 2.5 ... 6 mm²
  • Connecting Capacity Auxiliary Circuit: Flexible with Ferrule 1/2x 0.75 ... 1.5 mm² Flexible with Insulated Ferrule 1/2x 0.75 ... 1.5 mm² Flexible 1/2x 0.75 ... 1.5 mm² Rigid 1/2x 1 ... 1.5 mm²
  • Tightening Torque: Auxiliary Circuit 0.9 N·m Control Circuit 0.9 N·m Main Circuit 28 N·m
  • Wire Stripping Length: Auxiliary Circuit 8 mm Main Circuit 10 mm
  • Recommended Screw Driver: Pozidriv 2
  • Mounting Position: Position 1 to 6
Santa Clara Systems specialises in hard-to-find parts. Choose from our overstock inventory and save on 1SAM250000R1013 . Santa Clara Systems carries 35,877 items from ABB.
  • Undervoltage Releases
  • Shunt Trips
  • 3-Phase Bus Bars
  • Power In-Feed Blocks And Locking Devices For Protection Against Unauthorized Changes Are Available As Accessory.
  • The Ms116-20 Manual Motor Starter Is A Compact 45 Mm Width Devices With A Rated Operational Current Of Ie = 20.0 A. This Device Is Used To Manually Switch On And Off Motors And To Protect Them Reliably And Without The Need For A Fuse From Short-Circuits
  • Overload And Phase Failures. The Manual Motor Starter Offers A Rated Service Short-Circuit Breaking Capacity Ics = 10 Ka At 400 Vac And The Trip Class 10A. Further Features Are The Build-In Disconnect Function
  • Temperature Compensation
  • Trip-Free Mechanism And A Rotary Handle With A Clear Switch Position Indication. The Manual Motor Starter Is Suitable For Three- And Single-Phase Applications. Auxiliary Contacts
  • Signalling Contacts
  • Alternates

    • MS116-20
    • MS116 20
    • MS11620

    Common Types

    • 1SAM250000R10I3
    • 1SAM250000R10L3
    • 1SAM250000R1O13
    • 1SAM250000R1OI3
    • 1SAM250000R1OL3
    • 1SAM250000RI013
    • 1SAM250000RI0I3
    • 1SAM250000RI0L3
    • 1SAM250000RIO13
    • 1SAM250000RIOI3
    • 1SAM250000RIOL3
    • 1SAM250000RL013
    • 1SAM250000RL0I3
    • 1SAM250000RL0L3
    • 1SAM250000RLO13
    • 1SAM250000RLOI3
    • 1SAM250000RLOL3
    • 1SAM25000OR1013
    • 1SAM25000OR10I3
    • 1SAM25000OR10L3
    • 1SAM25000OR1O13
    • 1SAM25000OR1OI3
    • 1SAM25000OR1OL3
    • 1SAM25000ORI013
    • 1SAM25000ORI0I3

    Appended Numbers

    • 1SAM250000R1013-A
    • 1SAM250000R1013-B
    • 1SAM250000R1013-C
    • 1SAM250000R1013-D
    • 1SAM250000R1013-E
    • 1SAM250000R1013-F
    • 1SAM250000R1013-G
    • 1SAM250000R1013-H
    • 1SAM250000R1013-I
    • 1SAM250000R1013-J
    • 1SAM250000R1013-K
    • 1SAM250000R1013-L
    • 1SAM250000R1013-M
    • 1SAM250000R1013-N
    • 1SAM250000R1013-O
    • 1SAM250000R1013-P
    • 1SAM250000R1013-Q
    • 1SAM250000R1013-R
    • 1SAM250000R1013-S
    • 1SAM250000R1013-T
    • 1SAM250000R1013-U
    • 1SAM250000R1013-V
    • 1SAM250000R1013-W
    • 1SAM250000R1013-X
    • 1SAM250000R1013-Y
    • 1SAM250000R1013-Z

    Customers Are Also Buying

    We Deliver!

    Late West Coast Shipping Hours
    Late West Coast Shipping (5PM PST)
    Drop-Ship and Blind-Ship Specialists
    Expertly Packed Static-Limited
    Same-Day Service
    In-House Courier Domestic and International
    visa credit card logo mastercard credit card logo discover credit card logo american express credit card logo